Manuel d’utilisation Unitary products group D1EB036

20 pages 1.87 mb
Télécharger

Aller à la page of 20

Summary
  • Unitary products group D1EB036 - page 1

    INST ALLA TION MANUAL - 50 HZ CAUTION: READ ALL SAFETY GUIDES BEFORE YOU BEGIN TO INST ALL YOUR UNIT . SA VE THIS MANUAL CHAMPION ® SERIES SINGLE P ACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLED MODELS: D1EB036, 048 DIRECT DRIVE D1EB060 BEL T DRIVE (WORLD 50 HZ) 173858-YIM-A-0306 CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . ...

  • Unitary products group D1EB036 - page 2

    173858-YIM-A-0306 2 Unitary Products Group T ABLE OF CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 REPLACEMENT PARTS . . . . . . . . ...

  • Unitary products group D1EB036 - page 3

    173858-YIM-A-0306 Unitary Products Group 3 GENERAL Model D1EB units are factory assembled cooling only air con- ditioners designed for outdoor installation on a rooftop or a slab. The units are completely assembled on rigid, but easily removable base rails. All p iping, refri gerant ch arge, a nd elec- trical wiring is factory installed and tested. ...

  • Unitary products group D1EB036 - page 4

    173858-YIM-A-0306 4 Unitary Products Group should meet local codes an d unit weight. Do not tie the slab to the build ing foundation. 4. For roof top installation, be sure the structure will support the weight of the unit plus a ny field installed components. Unit must be installed on a le vel roof curb or appropriate angle iron frame providing ade ...

  • Unitary products group D1EB036 - page 5

    173858-YIM-A-0306 Unitary Products Group 5 Duct work should be designed and size d according to the methods of the Air Condition ing Contractors of America (ACCA), as set forth in their Manual D. A closed return duct system sha ll be used. This shall not pre- clude use of econo mizers or ve ntilation air intake. Flexibl e joints may be used in the ...

  • Unitary products group D1EB036 - page 6

    173858-YIM-A-0306 6 Unitary Products Group T ABLE 3: PHYSICAL DA T A COMPONENT MODELS DEB036 DEB048 DEB060 NOMINAL TONNAGE 3.0 4.0 5.0 COOLING PERFORMANCE RA TING T1 T2 T2 T1 T2 T3 T 1 T2 T3 Indoor DB/WB °C 27 / 19 29 / 19 21 / 15 27 / 19 29 / 19 21 / 15 27 / 19 29 / 19 21 / 15 Outdoor DB/WB °C 35 / 24 46 / 24 27 / 19 35 / 24 46 / 24 27 / 19 35 / ...

  • Unitary products group D1EB036 - page 7

    173858-YIM-A-0306 Unitary Products Group 7 POWER AND CONTROL WIRING Field wiring to the unit must conform to provision s of the cur- rent N.E.C. ANSI/NFP A No. 70 or C.E.C. and/or local ordi- nances. The unit must be electric ally grounded in accordance with local codes or , i n their absence, with th e N.E.C./C.E.C. V oltage tolerances which must ...

  • Unitary products group D1EB036 - page 8

    173858-YIM-A-0306 8 Unitary Products Group CHECKING SUPPLY AIR CFM T o check the supply air CF M after the initial balancing has been completed: 1. Remove the two ¼ inch dot plugs in the duct panel. 2. Insert at least 8 i nches of ¼ inch tubing into each of these holes for sufficient penetration into the airflow on both sides of the indoor coil. ...

  • Unitary products group D1EB036 - page 9

    173858-YIM-A-0306 Unitary Products Group 9 T ABLE 5: ADDITIONA L ST A TIC RESIST ANCE Size (T ons) Model Airflow m 3 /s (cfm) Wet Indoor Coil Pa (in.wc) Economizer 1 Pa (in.wc) Filter / Frame Kit Pa (in.wc) 036 (3.0) DEB 0.42 (900) 0.47 (1000) 0.52 (1 100) 0.57 (1200) 0.61 (1300) 0.66 (1400) 0.71 (1500) 12.45 (0.05) 14.95 (0.06) 17.44 (0.07) 17.44 ...

  • Unitary products group D1EB036 - page 10

    173858-YIM-A-0306 10 Unitary Products Group T ABLE 6: D1EB036 SUPERHEAT CHARGING (IMPERIAL) OUT DOOR TEMPERA TURE (°F) SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 1,300 CFM INDOOR WB T E MPERA TURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 21.1 21.6 22.1 22.7 23.2 23.8 24.3 25.3 26.4 26.9 27.4 70 19.5 20.0 20.6 21.1 21.7 22.2 22.8 24.0 25.1 25 ...

  • Unitary products group D1EB036 - page 11

    173858-YIM-A-0306 Unitary Products Group 11 T ABLE 8: D1EB048 SUPERHEAT CHARGING (IMPERIAL) OUTDOO R TEMPERA TURE (°F) SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 1,800 CFM INDOOR WB T EMPERATURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 19.9 21.0 22.1 23.3 24.4 25.6 26.7 28.0 29.3 30.0 30.7 70 16.5 17.9 19.2 20.6 22.0 23.4 24.8 26.3 27.8 28.6 ...

  • Unitary products group D1EB036 - page 12

    173858-YIM-A-0306 12 Unitary Products Group T ABLE 10: D1EB060 SUPERHEAT CHARGING (IMPERIAL) OUTDOOR TEMPERA TURE (°F) SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 2,000 CFM INDOOR WB T EMPERATURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 21.9 23.8 25.7 27 .6 29.4 31.3 33.2 34.2 35.1 35.6 36.1 70 16.0 18.4 20.7 23 .0 25.3 27.6 30.0 31.3 32.7 33 ...

  • Unitary products group D1EB036 - page 13

    173858-YIM-A-0306 Unitary Products Group 13 FIGURE 5 - UNIT DIMENSIONS +,*+92/ 7$*(&211 ´',$.12&.287 +,*+92/ 7$*(&211 ´',$.12&.287 /2:92/ 7$*(&211 ´',$.12&.287 6,'(? ...

  • Unitary products group D1EB036 - page 14

    173858-YIM-A-0306 14 Unitary Products Group SEQUENCE OF OPERA TION COOLING The following sequence s of operation are based on using a standard single-stage cooling thermostat. WITH POWER TO UNIT AND THERMOST A T IN COOLING MODE 1. If the fan switch on the thermo stat is in the “ON” position, the 24 volts at “G” will e nergize the “K1" ...

  • Unitary products group D1EB036 - page 15

    173858-YIM-A-0306 Unitary Products Group 15 FIGURE 3 - TYPICAL WIRING DIAGRA M 3 & 4 TON (380/415-3-50 POWER SUPPLY) ...

  • Unitary products group D1EB036 - page 16

    173858-YIM-A-0306 16 Unitary Products Group FIGURE 4 - TYPICAL WIRING DIAGRAM 5 TON (380/415-3-50 POWER SUPPLY) ...

  • Unitary products group D1EB036 - page 17

    173858-YIM-A-0306 Unitary Products Group 17 FIGURE 5 - TYPICAL WIRING DIAGRAM LEGEN D FIGURE 6 - TYPICAL WIRING DIAGRAM NOTE S &% &2035 ) )= +3 . . /3 0 0 0 5& 5& 63 63 63 63 7 &,5&8,7%5($.(59 $03 &2035(6625 )86(96(& ...

  • Unitary products group D1EB036 - page 18

    173858-YIM-A-0306 18 Unitary Products Group ...

  • Unitary products group D1EB036 - page 19

    173858-YIM-A-0306 Unitary Products Group 19 ...

  • Unitary products group D1EB036 - page 20

    Subject to change without notice. Print ed in U.S.A. 173858-YIM-A-0306 Copyright © 2006 by Unitary Products Gro up. All rights reserved. Supersedes: Nothing Unitary 5005 Norman Product s Y ork OK Group Drive 73069 ...

Fabricant Unitary products group Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilUnitary products group D1EB036 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Unitary products group
- manuels d’utilisations D1EB036
- fiches produit Unitary products group
- dépliants
- ou étiquettes-énergie Unitary products group D1EB036
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Unitary products group D1EB036.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Unitary products group D1EB036, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Unitary products group D1EB036. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Unitary products group D1EB036.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Unitary products group D1EB036, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Unitary products group D1EB036 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Unitary products group D1EB036.

Le manuel d’utilisation complet Unitary products group, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Unitary products group D1EB036 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Unitary products group D1EB036, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lUnitary products group D1EB036 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Unitary products group D1EB036 - qui devraient nous aider dans les premières étapes lors de l'utilisation Unitary products group D1EB036
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Unitary products group D1EB036
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Unitary products group D1EB036 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Unitary products group D1EB036?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Unitary products group D1EB036, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Unitary products group D1EB036 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)