    INST ALLA TION MANUAL - 50 HZ CAUTION: READ ALL SAFETY GUIDES BEFORE YOU BEGIN TO INST ALL YOUR UNIT . SA VE THIS MANUAL CHAMPION ® SERIES SINGLE P ACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLED MODELS: D1EB036, 048 DIRECT DRIVE D1EB060 BEL T DRIVE (WORLD 50 HZ) 173858-YIM-A-0306 CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . ...

  • Unitary products group D1EB036 - page 2

    173858-YIM-A-0306 2 Unitary Products Group T ABLE OF CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 REPLACEMENT PARTS . . . . . . . . ...

  • Unitary products group D1EB036 - page 3

    173858-YIM-A-0306 Unitary Products Group 3 GENERAL Model D1EB units are factory assembled cooling only air con- ditioners designed for outdoor installation on a rooftop or a slab. The units are completely assembled on rigid, but easily removable base rails. All p iping, refri gerant ch arge, a nd elec- trical wiring is factory installed and tested. ...

  • Unitary products group D1EB036 - page 4

    173858-YIM-A-0306 4 Unitary Products Group should meet local codes an d unit weight. Do not tie the slab to the build ing foundation. 4. For roof top installation, be sure the structure will support the weight of the unit plus a ny field installed components. Unit must be installed on a le vel roof curb or appropriate angle iron frame providing ade ...

  • Unitary products group D1EB036 - page 5

    173858-YIM-A-0306 Unitary Products Group 5 Duct work should be designed and size d according to the methods of the Air Condition ing Contractors of America (ACCA), as set forth in their Manual D. A closed return duct system sha ll be used. This shall not pre- clude use of econo mizers or ve ntilation air intake. Flexibl e joints may be used in the ...

  • Unitary products group D1EB036 - page 6

    173858-YIM-A-0306 6 Unitary Products Group T ABLE 3: PHYSICAL DA T A COMPONENT MODELS DEB036 DEB048 DEB060 NOMINAL TONNAGE 3.0 4.0 5.0 COOLING PERFORMANCE RA TING T1 T2 T2 T1 T2 T3 T 1 T2 T3 Indoor DB/WB °C 27 / 19 29 / 19 21 / 15 27 / 19 29 / 19 21 / 15 27 / 19 29 / 19 21 / 15 Outdoor DB/WB °C 35 / 24 46 / 24 27 / 19 35 / 24 46 / 24 27 / 19 35 / ...

  • Unitary products group D1EB036 - page 7

    173858-YIM-A-0306 Unitary Products Group 7 POWER AND CONTROL WIRING Field wiring to the unit must conform to provision s of the cur- rent N.E.C. ANSI/NFP A No. 70 or C.E.C. and/or local ordi- nances. The unit must be electric ally grounded in accordance with local codes or , i n their absence, with th e N.E.C./C.E.C. V oltage tolerances which must ...

  • Unitary products group D1EB036 - page 8

    173858-YIM-A-0306 8 Unitary Products Group CHECKING SUPPLY AIR CFM T o check the supply air CF M after the initial balancing has been completed: 1. Remove the two ¼ inch dot plugs in the duct panel. 2. Insert at least 8 i nches of ¼ inch tubing into each of these holes for sufficient penetration into the airflow on both sides of the indoor coil. ...

  • Unitary products group D1EB036 - page 9

    173858-YIM-A-0306 Unitary Products Group 9 T ABLE 5: ADDITIONA L ST A TIC RESIST ANCE Size (T ons) Model Airflow m 3 /s (cfm) Wet Indoor Coil Pa (in.wc) Economizer 1 Pa (in.wc) Filter / Frame Kit Pa (in.wc) 036 (3.0) DEB 0.42 (900) 0.47 (1000) 0.52 (1 100) 0.57 (1200) 0.61 (1300) 0.66 (1400) 0.71 (1500) 12.45 (0.05) 14.95 (0.06) 17.44 (0.07) 17.44 ...

  • Unitary products group D1EB036 - page 10

    173858-YIM-A-0306 10 Unitary Products Group T ABLE 6: D1EB036 SUPERHEAT CHARGING (IMPERIAL) OUT DOOR TEMPERA TURE (°F) SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 1,300 CFM INDOOR WB T E MPERA TURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 21.1 21.6 22.1 22.7 23.2 23.8 24.3 25.3 26.4 26.9 27.4 70 19.5 20.0 20.6 21.1 21.7 22.2 22.8 24.0 25.1 25 ...

  • Unitary products group D1EB036 - page 11

    173858-YIM-A-0306 Unitary Products Group 11 T ABLE 8: D1EB048 SUPERHEAT CHARGING (IMPERIAL) OUTDOO R TEMPERA TURE (°F) SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 1,800 CFM INDOOR WB T EMPERATURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 19.9 21.0 22.1 23.3 24.4 25.6 26.7 28.0 29.3 30.0 30.7 70 16.5 17.9 19.2 20.6 22.0 23.4 24.8 26.3 27.8 28.6 ...

  • Unitary products group D1EB036 - page 12

    173858-YIM-A-0306 12 Unitary Products Group T ABLE 10: D1EB060 SUPERHEAT CHARGING (IMPERIAL) OUTDOOR TEMPERA TURE (°F) SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 2,000 CFM INDOOR WB T EMPERATURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 21.9 23.8 25.7 27 .6 29.4 31.3 33.2 34.2 35.1 35.6 36.1 70 16.0 18.4 20.7 23 .0 25.3 27.6 30.0 31.3 32.7 33 ...

  • Unitary products group D1EB036 - page 13

    173858-YIM-A-0306 Unitary Products Group 13 FIGURE 5 - UNIT DIMENSIONS +,*+92/ 7$*(&211 ´',$.12&.287 +,*+92/ 7$*(&211 ´',$.12&.287 /2:92/ 7$*(&211 ´',$.12&.287 6,'(? ...

  • Unitary products group D1EB036 - page 14

    173858-YIM-A-0306 14 Unitary Products Group SEQUENCE OF OPERA TION COOLING The following sequence s of operation are based on using a standard single-stage cooling thermostat. WITH POWER TO UNIT AND THERMOST A T IN COOLING MODE 1. If the fan switch on the thermo stat is in the “ON” position, the 24 volts at “G” will e nergize the “K1" ...

  • Unitary products group D1EB036 - page 15

    173858-YIM-A-0306 Unitary Products Group 15 FIGURE 3 - TYPICAL WIRING DIAGRA M 3 & 4 TON (380/415-3-50 POWER SUPPLY) ...

  • Unitary products group D1EB036 - page 16

    173858-YIM-A-0306 16 Unitary Products Group FIGURE 4 - TYPICAL WIRING DIAGRAM 5 TON (380/415-3-50 POWER SUPPLY) ...

  • Unitary products group D1EB036 - page 17

    173858-YIM-A-0306 Unitary Products Group 17 FIGURE 5 - TYPICAL WIRING DIAGRAM LEGEN D FIGURE 6 - TYPICAL WIRING DIAGRAM NOTE S &% &2035 ) )= +3 . . /3 0 0 0 5& 5& 63 63 63 63 7 &,5&8,7%5($.(59 $03 &2035(6625 )86(96(& ...

  • Unitary products group D1EB036 - page 18

    173858-YIM-A-0306 18 Unitary Products Group ...

  • Unitary products group D1EB036 - page 19

    173858-YIM-A-0306 Unitary Products Group 19 ...

  • Unitary products group D1EB036 - page 20

    Subject to change without notice. Print ed in U.S.A. 173858-YIM-A-0306 Copyright © 2006 by Unitary Products Gro up. All rights reserved. Supersedes: Nothing Unitary 5005 Norman Product s Y ork OK Group Drive 73069 ...

メーカー Unitary products group カテゴリー Air Conditioner

Unitary products group D1EB036のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- D1EB036の取扱説明書
- Unitary products groupの製品カード
- パンフレット
- またはUnitary products group D1EB036の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Unitary products group D1EB036の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Unitary products group D1EB036の取り付け説明書、サービスマニュアル、簡易説明書、またはUnitary products group D1EB036のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Unitary products group D1EB036の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Unitary products group D1EB036デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがUnitary products group D1EB036を使用するのを助ける技術的文書のことです。説明書は通常、全てのUnitary products group D1EB036ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Unitary products groupの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Unitary products group D1EB036の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははUnitary products group D1EB036の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Unitary products group D1EB036に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Unitary products group D1EB036デバイスの基本機能を使うにあたってのヒント。 Unitary products group D1EB036のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Unitary products group D1EB036に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるUnitary products group D1EB036のメーカー/サービスへの連絡先に関する情報。

Unitary products group D1EB036についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもUnitary products group D1EB036の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがUnitary products group D1EB036で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)