Manuel d’utilisation Allied Air Enterprises 506271-01

14 pages 0.15 mb
Télécharger

Aller à la page of 14

Summary
  • Allied Air Enterprises 506271-01 - page 1

    506271-01 Page 1 of 14 Issue 0921 Save these instructions for future reference INST ALLA TION INSTRUCTIONS RPGE/RGE Series Gas Heating/Electric Cooling Package Unit Do not store combustible materials, including gasoline and other flammable vapors and liquids, near the furnace, vent pipe, or warm air ducts. Such actions could cause property damage, ...

  • Allied Air Enterprises 506271-01 - page 2

    Page 2 of 14 506271-01 Issue 0921 INST ALLA TION T hese instructions must be hung on or near the furnace in a conspicuous place. These furnace units are single package air conditioners with gas heat designed for outdoor installation on a roof top or a slab. The units are completely assembled. All piping, refrigerant charge, and electrical wiring ar ...

  • Allied Air Enterprises 506271-01 - page 3

    506271-01 Page 3 of 14 Issue 0921 In the U.S., units may be installed on combustible floors made from wood or class A, B, or C roof covering material. In Canada, units may be installed on combustible floors. Units must be installed out doors. Service Access Access to all serviceable components is provided by four removable panels: blower comp artme ...

  • Allied Air Enterprises 506271-01 - page 4

    Page 4 of 14 506271-01 Issue 0921 Minimum horizontal clearance of 4' from electric meters, gas meters, regulator , and relief equipment is required. In addition to the above requirements, consideration must be given to prevent unwanted ice buildup from the vent condensate. The vent should not be located on the side of a building where the prev ...

  • Allied Air Enterprises 506271-01 - page 5

    506271-01 Page 5 of 14 Issue 0921 The supply and return air duct systems should be designed for the CFM and static requirement s of the job. They should not be sized by matching the dimensions of the duct connections on the unit. Filters Filters are not supplied with the unit. Filters must always be installed ahead of the evaporator coil and must b ...

  • Allied Air Enterprises 506271-01 - page 6

    Page 6 of 14 506271-01 Issue 0921 Gas piping recommendations: • A drip leg and a ground joint union must be installed in the gas piping. A ground joint union is recommended by the manifold/valve. • When required by local codes, a manual shutoff valve may have to be installed outside of the unit. • Use pipe thread sealing compound resistant to ...

  • Allied Air Enterprises 506271-01 - page 7

    506271-01 Page 7 of 14 Issue 0921 All wiring should be done in accordance with the National Electrical Code, ANSI/NFP A No. 70 (latest edition); Canadian Electrical Code Part 1, CSA C22.1 (latest edition); or local codes where they prevail. Use wiring with a temperature limitation of 75°C minimum. Run the 208 or 230 volt, 60 hertz electric power s ...

  • Allied Air Enterprises 506271-01 - page 8

    Page 8 of 14 506271-01 Issue 0921 ST ART -UP Pre-St art Check List Complete the following checks before starting the unit: 1. Check the type of gas being supplied. Be sure it is the same as listed on the unit nameplate. 2 . Make sure that the vent cover has been properly installed. For Y our Safety Read Before Lighting T o Light Main Burners: 1. T ...

  • Allied Air Enterprises 506271-01 - page 9

    506271-01 Page 9 of 14 Issue 0921 Manifold Gas Pressure Adjustment Regulator – Natural Gas For purpose of input adjustment, the minimum permissible gas supply pressure is 5" w .c. for natural gas. Gas input must never exceed the input capacity shown on the rating plate. The furnace is equipped for natural gas rated input s with manifold pres ...

  • Allied Air Enterprises 506271-01 - page 10

    Page 10 of 14 506271-01 Issue 0921 7. After reassembly of all p arts is complete and all wires are reconnected, open the main manual gas shutoff valve; check for and correct any gas leaks. T urn electrical power on, initiate a call for heat, and check for proper burner operation. 8. Install burner access panel. Heat Anticipator The heat anticipator ...

  • Allied Air Enterprises 506271-01 - page 11

    506271-01 Page 11 of 14 Issue 0921 10-second interval, then the ignition control will de- energize the gas valve. 6. The ignition control is designed to repeat this “trial for ignition” a total of three times. If, at the end of the third trial, flame still has not been established, then the ignition control will try to light again 1 hour later ...

  • Allied Air Enterprises 506271-01 - page 12

    Page 12 of 14 506271-01 Issue 0921 Burners T o clean the burners, first remove them from the furnace as explained in Burner Instructions on page 9. V acuum and/or brush as required. V ent Outlet Visually inspect vent outlet periodically to make sure that there is no buildup of soot or dirt. If necessary , clean to maintain adequate opening to disch ...

  • Allied Air Enterprises 506271-01 - page 13

    506271-01 Page 13 of 14 Issue 0921 Wiring Diagram – Single Phase Figure 8 ...

  • Allied Air Enterprises 506271-01 - page 14

    Page 14 of 14 506271-01 Issue 0921 NOTES ...

Fabricant Allied Air Enterprises Catégorie Gas Heater

Les documents que nous recevons du fabricant de l'appareilAllied Air Enterprises 506271-01 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Allied Air Enterprises
- manuels d’utilisations 506271-01
- fiches produit Allied Air Enterprises
- dépliants
- ou étiquettes-énergie Allied Air Enterprises 506271-01
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Allied Air Enterprises 506271-01.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Allied Air Enterprises 506271-01, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Allied Air Enterprises 506271-01. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Allied Air Enterprises 506271-01.

Manuel d’utilisation complet de l’appareil Allied Air Enterprises 506271-01, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Allied Air Enterprises 506271-01 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Allied Air Enterprises 506271-01.

Le manuel d’utilisation complet Allied Air Enterprises, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Allied Air Enterprises 506271-01 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Allied Air Enterprises 506271-01, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAllied Air Enterprises 506271-01 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Allied Air Enterprises 506271-01 - qui devraient nous aider dans les premières étapes lors de l'utilisation Allied Air Enterprises 506271-01
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Allied Air Enterprises 506271-01
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Allied Air Enterprises 506271-01 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Allied Air Enterprises 506271-01?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Allied Air Enterprises 506271-01, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Allied Air Enterprises 506271-01 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)