    USER MAN U A L MODEL 1094A NetLink™ HDSL Multi-Rate Symmetric DSL Modem Part# 07M1094A-B Doc# 032042UB Revised 07/22/99 SALES OFFICE (301)975-1000 TECHNICAL SUPPO R T (301)975-1007 http://ww w .patton.com CERTIFIED An ISO-9001 Certified Company ...

  • Patton electronic 1094A - page 2

    T T A A B B L L E E O O F F C C O O N N T T E E N N T T S S SECTION P AGE 1.0 W arranty Information .............................................................2 1.1 Radio and TV Interference 1.2. CE Notice 1.3 Service 2.0 General Information ...............................................................4 2.1 Features 2.2 Description 3.0 Configur ...

  • Patton electronic 1094A - page 3

    1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container . This number may be obtained from Patton Electronics T echnical Service at: T el: (301)975-1007 Email: support@patton.com www: h ...

  • Patton electronic 1094A - page 4

    3 3 . . 0 0 C C O O N N F F I I G G U U R R A A T T I I O O N N The Model 1094A is equipped with three sets of eight DIP switch- es, which allow configuration of the unit for a wide variety of applica- tions. This section describes switch locations and explains all possible configurations. 3.1 CONFIGURING THE HARDW ARE DIP SWITCHES The 24 external ...

  • Patton electronic 1094A - page 5

    7 Switches S2-6 and S2-7: Clock Mode Use Switches S2-6 and S2-7 to configure the 1094A for internal, external, or receive recover clock mode. Switch S2-8: Enable/Disable Loop T ests from DTE Use Switch S2-8 to allow Model 1094A to enter loopback tests when the DTE raises the appropriate loop request pin. S2-8 Setting On Response to DTE Loopback Req ...

  • Patton electronic 1094A - page 6

    9 Switch S3-7: Reset Software Defaults Switch S3-7 allows the user to reset the software configured facto- ry defaults. S3-7 Factory T est On Normal Operation Off Reset Switch S3-8: T ransmit Data (TD) Sampling Point Switch 3-8 controls the T ransmit Data (TD) sampling point. S3-8 Setting Description On Normal TD sampled on the falling edge of the ...

  • Patton electronic 1094A - page 7

    11 4.2 CONNECTING THE SERIAL PORT The serial port interface on the Model 1094A uses interchange- able QuikConnect™ Modules. Each QuikConnect™ Module has a 50-pin card edge connector on one side and a serial port interface on the other . Figure 4 below shows how a QuikConnect™ Module plugs into the back of the Model 1094A. 4.2.1 Changing QuikC ...

  • Patton electronic 1094A - page 8

    4.2.4 Configuring the X.21 QuikConnect™ Module The serial port on the X.21 QuikConnect™ Module is default wired as a DCE, but may be switched to a DTE. This is done by reversing the orientation of the DCE/DTE strap, as described below: T o reverse DCE/DTE orientation, remove the module according to the instructions in Section 4.2.1 . The DCE/DT ...

  • Patton electronic 1094A - page 9

    5 5 . . 0 0 O O P P E E R R A A T T I I O O N N Once the Model 1094A is properly configured and installed, it should operate transparently . This sections describes power-up, read- ing the LED status monitors, and using the built-in loopback test modes. 5.1 POWER-UP T o apply power to the Model 1094A, first be sure that you have read Section 4.3 , ...

  • Patton electronic 1094A - page 10

    Framer The framer is used to determine the status of the line. In normal operation the framer trans- mits and expects to receive framed packets from the far end. If the framer receives framed packets from the far end, CTS and CD will be active. If framed packets are not received, CTS and CD will be inactive. The restart procedure uses this informat ...

  • Patton electronic 1094A - page 11

    5.3.2 Loops and Patterns The following section describes the T est Modes used in the Model 1094A. At the bottom of each T est Mode, a figure is included to show the data path. Local Loop There are two different modes of operation for a Local Loop depending on the status of the units at the time that the Local Loop is initiated. If the units are not ...

  • Patton electronic 1094A - page 12

    Local Loop After the 51 1/51 1E pattern times out, the ER led with 51 1/51 1E will begin flashing. It will remain this way until (continued) the pattern generator switch is turned off. Note that the data at the local DTE and the remote DTE are not valid. Because the data is unframed there is no way for the framer to send this data out to the DTE. T ...

  • Patton electronic 1094A - page 13

    Remote Digital The Remote Digital Loop with 51 1/51 1E is Loop with shown above. After RDL is established the 51 1/51 1E Remote units' Restart T imer is set to one minute. This has been done because when the 51 1/51 1E generator is started on the local unit, the Remote framer begins seeing unframed packets. The Remote unit can not distinguish ...

  • Patton electronic 1094A - page 14

    5.3.3 Using the V .52 (BER) T est Pattern Generator T o use the V .52 BER tests in conjunction with the Remote Digital Loopback tests (or with Local Line Loopback tests), follow these instructions: 1. Locate the “51 1/51 1E” toggle switch on the front panel of the 1094A and move it UP . This activates the V .52 BER test mode and transmits a “ ...

  • Patton electronic 1094A - page 15

    A A P P P P E E N N D D I I X X B B P A TTON ELECTRONICS MODEL 1094A F ACTOR Y REPLACEMENT P ARTS AND ACCESSORIES Patton Electronics Model # Description IM1/A ...............................V .24 with DB25F IM1/B ...............................RS422/RS530 with DB25F IM1/C ...............................V .35 with M34F IM1/D ........................ ...

  • Patton electronic 1094A - page 16

    A A P P P P E E N N D D I I X X C C P A TTON ELECTRONICS MODEL 1094A INTERF ACE PIN ASSIGNMENTS (Continued) V .35 Interface (M/34F Female Connector) (DCE Configuration) Pin # Signal B ...........................SGND (Signal Ground) C ...........................R TS (Request to Send) D ...........................CTS (Clear to Send) E ............... ...

  • Patton electronic 1094A - page 17

    A A P P P P E E N N D D I I X X D D P A TTON ELECTRONICS MODEL 1094A TRANSMISSION DIST ANCES Copyright © 1999 Patton Electronics Company All Rights Reserved 31 Line Rat e DTE Rates kbps feet m iles km feet miles km 144 64, 128 20700 3.9 6.2 24500 4. 6 7. 3 272 192, 256 17400 3.3 5.2 24200 4. 5 7. 2 400 320, 384 15100 2.9 4.6 22600 4. 2 6. 7 528 44 ...

Fabricant Patton electronic Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilPatton electronic 1094A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Patton electronic
- manuels d’utilisations 1094A
- fiches produit Patton electronic
- dépliants
- ou étiquettes-énergie Patton electronic 1094A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Patton electronic 1094A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Patton electronic 1094A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Patton electronic 1094A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Patton electronic 1094A.

Manuel d’utilisation complet de l’appareil Patton electronic 1094A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Patton electronic 1094A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Patton electronic 1094A.

Le manuel d’utilisation complet Patton electronic, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Patton electronic 1094A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Patton electronic 1094A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lPatton electronic 1094A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Patton electronic 1094A - qui devraient nous aider dans les premières étapes lors de l'utilisation Patton electronic 1094A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Patton electronic 1094A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Patton electronic 1094A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Patton electronic 1094A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Patton electronic 1094A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Patton electronic 1094A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)