Manual Patton electronic 1094A

17 pages 0.1 mb
Download

Go to site of 17

Summary
  • Patton electronic 1094A - page 1

    USER MAN U A L MODEL 1094A NetLink™ HDSL Multi-Rate Symmetric DSL Modem Part# 07M1094A-B Doc# 032042UB Revised 07/22/99 SALES OFFICE (301)975-1000 TECHNICAL SUPPO R T (301)975-1007 http://ww w .patton.com CERTIFIED An ISO-9001 Certified Company ...

  • Patton electronic 1094A - page 2

    T T A A B B L L E E O O F F C C O O N N T T E E N N T T S S SECTION P AGE 1.0 W arranty Information .............................................................2 1.1 Radio and TV Interference 1.2. CE Notice 1.3 Service 2.0 General Information ...............................................................4 2.1 Features 2.2 Description 3.0 Configur ...

  • Patton electronic 1094A - page 3

    1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container . This number may be obtained from Patton Electronics T echnical Service at: T el: (301)975-1007 Email: support@patton.com www: h ...

  • Patton electronic 1094A - page 4

    3 3 . . 0 0 C C O O N N F F I I G G U U R R A A T T I I O O N N The Model 1094A is equipped with three sets of eight DIP switch- es, which allow configuration of the unit for a wide variety of applica- tions. This section describes switch locations and explains all possible configurations. 3.1 CONFIGURING THE HARDW ARE DIP SWITCHES The 24 external ...

  • Patton electronic 1094A - page 5

    7 Switches S2-6 and S2-7: Clock Mode Use Switches S2-6 and S2-7 to configure the 1094A for internal, external, or receive recover clock mode. Switch S2-8: Enable/Disable Loop T ests from DTE Use Switch S2-8 to allow Model 1094A to enter loopback tests when the DTE raises the appropriate loop request pin. S2-8 Setting On Response to DTE Loopback Req ...

  • Patton electronic 1094A - page 6

    9 Switch S3-7: Reset Software Defaults Switch S3-7 allows the user to reset the software configured facto- ry defaults. S3-7 Factory T est On Normal Operation Off Reset Switch S3-8: T ransmit Data (TD) Sampling Point Switch 3-8 controls the T ransmit Data (TD) sampling point. S3-8 Setting Description On Normal TD sampled on the falling edge of the ...

  • Patton electronic 1094A - page 7

    11 4.2 CONNECTING THE SERIAL PORT The serial port interface on the Model 1094A uses interchange- able QuikConnect™ Modules. Each QuikConnect™ Module has a 50-pin card edge connector on one side and a serial port interface on the other . Figure 4 below shows how a QuikConnect™ Module plugs into the back of the Model 1094A. 4.2.1 Changing QuikC ...

  • Patton electronic 1094A - page 8

    4.2.4 Configuring the X.21 QuikConnect™ Module The serial port on the X.21 QuikConnect™ Module is default wired as a DCE, but may be switched to a DTE. This is done by reversing the orientation of the DCE/DTE strap, as described below: T o reverse DCE/DTE orientation, remove the module according to the instructions in Section 4.2.1 . The DCE/DT ...

  • Patton electronic 1094A - page 9

    5 5 . . 0 0 O O P P E E R R A A T T I I O O N N Once the Model 1094A is properly configured and installed, it should operate transparently . This sections describes power-up, read- ing the LED status monitors, and using the built-in loopback test modes. 5.1 POWER-UP T o apply power to the Model 1094A, first be sure that you have read Section 4.3 , ...

  • Patton electronic 1094A - page 10

    Framer The framer is used to determine the status of the line. In normal operation the framer trans- mits and expects to receive framed packets from the far end. If the framer receives framed packets from the far end, CTS and CD will be active. If framed packets are not received, CTS and CD will be inactive. The restart procedure uses this informat ...

  • Patton electronic 1094A - page 11

    5.3.2 Loops and Patterns The following section describes the T est Modes used in the Model 1094A. At the bottom of each T est Mode, a figure is included to show the data path. Local Loop There are two different modes of operation for a Local Loop depending on the status of the units at the time that the Local Loop is initiated. If the units are not ...

  • Patton electronic 1094A - page 12

    Local Loop After the 51 1/51 1E pattern times out, the ER led with 51 1/51 1E will begin flashing. It will remain this way until (continued) the pattern generator switch is turned off. Note that the data at the local DTE and the remote DTE are not valid. Because the data is unframed there is no way for the framer to send this data out to the DTE. T ...

  • Patton electronic 1094A - page 13

    Remote Digital The Remote Digital Loop with 51 1/51 1E is Loop with shown above. After RDL is established the 51 1/51 1E Remote units' Restart T imer is set to one minute. This has been done because when the 51 1/51 1E generator is started on the local unit, the Remote framer begins seeing unframed packets. The Remote unit can not distinguish ...

  • Patton electronic 1094A - page 14

    5.3.3 Using the V .52 (BER) T est Pattern Generator T o use the V .52 BER tests in conjunction with the Remote Digital Loopback tests (or with Local Line Loopback tests), follow these instructions: 1. Locate the “51 1/51 1E” toggle switch on the front panel of the 1094A and move it UP . This activates the V .52 BER test mode and transmits a “ ...

  • Patton electronic 1094A - page 15

    A A P P P P E E N N D D I I X X B B P A TTON ELECTRONICS MODEL 1094A F ACTOR Y REPLACEMENT P ARTS AND ACCESSORIES Patton Electronics Model # Description IM1/A ...............................V .24 with DB25F IM1/B ...............................RS422/RS530 with DB25F IM1/C ...............................V .35 with M34F IM1/D ........................ ...

  • Patton electronic 1094A - page 16

    A A P P P P E E N N D D I I X X C C P A TTON ELECTRONICS MODEL 1094A INTERF ACE PIN ASSIGNMENTS (Continued) V .35 Interface (M/34F Female Connector) (DCE Configuration) Pin # Signal B ...........................SGND (Signal Ground) C ...........................R TS (Request to Send) D ...........................CTS (Clear to Send) E ............... ...

  • Patton electronic 1094A - page 17

    A A P P P P E E N N D D I I X X D D P A TTON ELECTRONICS MODEL 1094A TRANSMISSION DIST ANCES Copyright © 1999 Patton Electronics Company All Rights Reserved 31 Line Rat e DTE Rates kbps feet m iles km feet miles km 144 64, 128 20700 3.9 6.2 24500 4. 6 7. 3 272 192, 256 17400 3.3 5.2 24200 4. 5 7. 2 400 320, 384 15100 2.9 4.6 22600 4. 2 6. 7 528 44 ...

Manufacturer Patton electronic Category Network Card

Documents that we receive from a manufacturer of a Patton electronic 1094A can be divided into several groups. They are, among others:
- Patton electronic technical drawings
- 1094A manuals
- Patton electronic product data sheets
- information booklets
- or energy labels Patton electronic 1094A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Patton electronic 1094A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Patton electronic 1094A, service manual, brief instructions and user manuals Patton electronic 1094A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Patton electronic 1094A.

A complete manual for the device Patton electronic 1094A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Patton electronic 1094A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Patton electronic 1094A.

A complete Patton electronic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Patton electronic 1094A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Patton electronic 1094A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Patton electronic 1094A, that we can find in the current document
3. Tips how to use the basic functions of the device Patton electronic 1094A - which should help us in our first steps of using Patton electronic 1094A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Patton electronic 1094A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Patton electronic 1094A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Patton electronic 1094A?

Use the form below

If you did not solve your problem by using a manual Patton electronic 1094A, ask a question using the form below. If a user had a similar problem with Patton electronic 1094A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)