Manuel d’utilisation Quantum 6-01376-07

32 pages 0.27 mb
Télécharger

Aller à la page of 32

Summary
  • Quantum 6-01376-07 - page 1

    6-01376-07 StorNext 3.1 ® StorNext File System T uning Guide File System T uning Guide File System T uning Guide ...

  • Quantum 6-01376-07 - page 2

    StorNext 3.1 File System Tuning Guide, 6-01376-07 , Ver. A, Rel. 3.1 , October 2007, Made in USA. Quantum Corporation provides this publ ication “as is” without warranty of an y kind, either express or implied, including but not limited to the implied warranties of merc hantability or fitness for a particular purpose. Quantum Corporation may re ...

  • Quantum 6-01376-07 - page 3

    StorNext File System Tuning Gu ide i Content s Chapter 1 StorNext File System Tuning 1 The Underlying Storage System ............. ... ......... .............. .............. .............. ... 1 RAID Cache Configuration .............. .............. .............. ............... .............. 2 RAID Write-Back Caching .... .............. ....... ...

  • Quantum 6-01376-07 - page 4

    StorNext File System Tuning Guide 1 0 S torNext File System T uning The StorNext File System (SNFS) pr ovides extremely high performance for widely varying scenarios. Many factors determine the level of performance you will realiz e. In particular, the performance characteristics of the underlying st orage system are the most critical factors. Howe ...

  • Quantum 6-01376-07 - page 5

    StorNext File System T uning The Underlying Storage System StorNext File System Tuning Guide 2 RAID Cache Configuration 0 The single most i mportant RAID tuning component is the cache configuration. This is particular ly t rue for small I/O operat ions. Contemporary RAID systems such as the EMC CX series and the various Engenio systems provide exce ...

  • Quantum 6-01376-07 - page 6

    StorNext File System T uning The Underlying Storage System StorNext File System Tuning Guide 3 File System Mana ger (FSM) stati stics reports in the cvlog file. For example, here is a message line from the cvlog file: PIO HiPriWr SUMMAR Y SnmsMetaDisk0 sysavg/350 sysmin/333 sysmax/367 This statistics message rep orts av erage, minimum, and maximum ...

  • Quantum 6-01376-07 - page 7

    StorNext File System T uning The Underlying Storage System StorNext File System Tuning Guide 4 unusual cases, it severely degrades typical sce narios. Therefore, it is unsuitable for most environments. RAID Level, Segment Size, and S tripe Size 0 Configuration settings such as RAID level, segment si ze, and stripe size are very important and cannot ...

  • Quantum 6-01376-07 - page 8

    StorNext File System T uning File Size Mix and Application I/O Characteristics StorNext File System Tuning Guide 5 File Size Mix and Application I/O Characteristics It is always valuabl e to understand th e file size mix of the target dataset as well as the application I/O characte ristics. This includes t he number of concurrent streams, proportio ...

  • Quantum 6-01376-07 - page 9

    StorNext File System T uning File Size Mix and Application I/O Characteristics StorNext File System Tuning Guide 6 It is usually best to configure the RA ID stripe size no greater than 256K for optimal small file buffer cache performance. For more buffer cache configuration settings, see Mount Command Options on page 17. NFS / CIFS 0 It i s b es t ...

  • Quantum 6-01376-07 - page 10

    StorNext File System T uning The Metadata Network StorNext File System Tuning Guide 7 The Metadat a Network As with any client/server protocol, SNFS perfor mance is subject to the limitations of the underlying network. Therefore, it is recommended that you use a dedicated Metadata Networ k to avoid contention with other network traffic. Either 100B ...

  • Quantum 6-01376-07 - page 11

    StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 8 Some metadata operations such as fi le creation can be CPU intensive, and benefit from increased CPU power. The MDC platform is important in these scenarios because lower clock- speed CPUs such as Sparc and M ips degrade performance. Other operations can ...

  • Quantum 6-01376-07 - page 12

    StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 9 Example: [stripeGroup RegularFiles] S tatus UP Exclusive No ##Non-Exclusive stripeGroup for all Fi les## Read Enabled Wr it e Enabled S trip eBreadth 256K MultiPathMethod Rotate Node CvfsDisk6 0 Node CvfsDisk7 1 Affinities 0 Affinities are another stripe ...

  • Quantum 6-01376-07 - page 13

    StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 10 Str i p eB re a dth 0 T h i s s e t t i n g m u s t m a t c h t h e R A I D s t r i p e s i z e o r b e a m u l t i p l e o f t h e R A I D stripe size. Matching th e RAID stripe size i s usually the most optimal setting. However, depending on the RAID ...

  • Quantum 6-01376-07 - page 14

    StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 11 InodeCacheSize 0 This setting consumes about 800-1000 bytes of memory times the nu mber specified. Increasing t his value can reduce latency of any metadat a operation by performing a hot cache access to inode information instead of an I/O to get inode ...

  • Quantum 6-01376-07 - page 15

    StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 12 Settings greater than 64K are not recommended because performance will be adversel y impacted due to in efficient metad ata I/O operations. Values less than 16K are not reco mmended in most scenarios because startup and failover time may be ad versely i ...

  • Quantum 6-01376-07 - page 16

    StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 13 man cvfs_config page.) T he snfsdefrag man page explains the command options in greater detail. FSM hourly statistics reporting is another very useful tool. This can show you the mix of metadata operations be ing invoked by cl ient processes, as well as ...

  • Quantum 6-01376-07 - page 17

    StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 14 SNFS supports the Windows Perfmon utility. This provides many useful statistics counters for the SNFS client component. To instal l, obtain a copy of cvfsperf .dll from the SCM team in Denver and copy it into the c:/ winnt/system32 directory on the SN F ...

  • Quantum 6-01376-07 - page 18

    StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 15 The “PERF: VFS” trace shows throughput measured for the read or write system call and significant aspects of the I/O, incl uding: •D m a : D M A •B u f : B u f f e r e d • Eof: File extended • Algn: Well-formed DMA I/O • Shr: File is share ...

  • Quantum 6-01376-07 - page 19

    StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 16 • Identify read/modify/w rite condition. If buffered VFS writes are causing De vice reads, it might be beneficial to match I/O request size to a multiple of t he “cachebufsize” (default 64KB; see mount_cvfs man page). Another way to avoid this is ...

  • Quantum 6-01376-07 - page 20

    StorNext File System T uning The Metadata Controller System StorNext File System Tuning Guide 17 Mount Command Options 0 The following SNFS mount command settings are explained in greater detail in the mount_cvfs man page. The default size of the buffer cache varies by platform and main memory size, and ranges between 32MB and 256M B. And, by defau ...

  • Quantum 6-01376-07 - page 21

    StorNext File System T uning The Distributed LAN (Disk Proxy) Networks StorNext File System Tuning Guide 18 SNFS External API 0 The SNFS External API might be useful in some scenarios because it offers programmatic use of special SN FS performance capabilities such as affinities, preallocation, and quality of service. For more information, see the ...

  • Quantum 6-01376-07 - page 22

    StorNext File System T uning The Distributed LAN (Disk Proxy) Networks StorNext File System Tuning Guide 19 is set to auto-detect but the host is set to 1000Mb/full , you will observe a high error rate and extremely poor perfor mance. On Linux the ethto ol command can be very useful to invest igate and a djust speed/duplex settings. In some cases, ...

  • Quantum 6-01376-07 - page 23

    StorNext File System T uning The Distributed LAN (Disk Proxy) Networks StorNext File System Tuning Guide 20 Figure 1 Multi-NIC Hardware and IP Configurati on Diagram In the diagram there are two subnetwork s: the blue subnetwork (10.0.0.x) and the red subnetwork (192.168.9.x). Se rvers such as S1 are connecte d to both the blue and red subnetwork s ...

  • Quantum 6-01376-07 - page 24

    StorNext File System T uning Distributed LAN Servers StorNext File System Tuning Guide 21 Distributed LAN Servers Distributed LAN Servers must ha ve suff icient memory. When a Distributed LAN Server does not have sufficient me mory, its performance in servicing Distributed LAN I/O requests might suffer. In some cases (particul arly on Windows,) it ...

  • Quantum 6-01376-07 - page 25

    StorNext File System T uning Distributed LAN Client Vs. Legacy Network Attached Storage StorNext File System Tuning Guide 22 Performance 0 DLC outperforms NFS and CIFS for single-stream I/O and provides higher aggregate bandwidth. For in ferior NFS client implementations, the difference can be more th an a factor of two. DLC also makes extremely ef ...

  • Quantum 6-01376-07 - page 26

    StorNext File System T uning Windows Memory Requirements StorNext File System Tuning Guide 23 Therefore, DLC provides incr eased st abilit y that is comparable to the StorNext SAN Client. Consistent Security Model 0 DLC clients hav e the same security mo del as StorNext SAN clients. When CIFS and NFS are used, some security models aren’t supporte ...

  • Quantum 6-01376-07 - page 27

    StorNext File System T uning Windows Memory Requirements StorNext File System Tuning Guide 24 The first is the Directory Cach e Size . The default is 10 (MB). If you do not have large directories, or do not pe rform lots of directory scans, this number can be reduced to 1 or 2 MB. The impact wil l be slightly slower directory lookups in directories ...

  • Quantum 6-01376-07 - page 28

    StorNext File System T uning Sample FSM Configuration File StorNext File System Tuning Guide 25 Sample FSM Configuration File This sample configuration file is locat ed in the SNFS install directory under the examples subdirectory named example.cfg. # **************************************************************************** # A global section fo ...

  • Quantum 6-01376-07 - page 29

    StorNext File System T uning Sample FSM Configuration File StorNext File System Tuning Guide 26 MAX(StripeBreadth) # MaxMBPerClientReserve 50 # in MBs, default 100 MB reserved per client # OpHangLimitSecs 300 # default 180 secs # DataMigrationThreadPoolSize 128 # Managed only, default 8 # ************************************************************ ...

  • Quantum 6-01376-07 - page 30

    StorNext File System T uning Sample FSM Configuration File StorNext File System Tuning Guide 27 [Disk CvfsDisk4] Status UP Type VideoDrive [Disk CvfsDisk5] Status UP Type VideoDrive [Disk CvfsDisk6] Status UP Type VideoDrive [Disk CvfsDisk7] Status UP Type VideoDrive [Disk CvfsDisk8] Status UP Type VideoDrive [Disk CvfsDisk9] Status UP Type VideoDr ...

  • Quantum 6-01376-07 - page 31

    StorNext File System T uning Sample FSM Configuration File StorNext File System Tuning Guide 28 [Disk CvfsDisk17] Status UP Type DataDrive # **************************************************************************** # A stripe section for defining stripe groups. # **************************************************************************** [Strip ...

  • Quantum 6-01376-07 - page 32

    StorNext File System T uning Sample FSM Configuration File StorNext File System Tuning Guide 29 [StripeGroup AudioFiles] Status UP Exclusive Yes ##Exclusive StripeGroup for Audio File Only## Affinity AudioFiles Read Enabled Write Enabled StripeBreadth 1M MultiPathMethod Rotate Node CvfsDisk10 0 Node CvfsDisk11 1 Node CvfsDisk12 2 Node CvfsDisk13 3 ...

Fabricant Quantum Catégorie Webcam

Les documents que nous recevons du fabricant de l'appareilQuantum 6-01376-07 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Quantum
- manuels d’utilisations 6-01376-07
- fiches produit Quantum
- dépliants
- ou étiquettes-énergie Quantum 6-01376-07
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Quantum 6-01376-07.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Quantum 6-01376-07, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Quantum 6-01376-07. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Quantum 6-01376-07.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Quantum 6-01376-07, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Quantum 6-01376-07 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Quantum 6-01376-07.

Le manuel d’utilisation complet Quantum, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Quantum 6-01376-07 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Quantum 6-01376-07, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lQuantum 6-01376-07 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Quantum 6-01376-07 - qui devraient nous aider dans les premières étapes lors de l'utilisation Quantum 6-01376-07
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Quantum 6-01376-07
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Quantum 6-01376-07 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Quantum 6-01376-07?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Quantum 6-01376-07, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Quantum 6-01376-07 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)