Manuel d’utilisation ADTRAN E220 HFAC HDSL

20 pages 0.11 mb
Télécharger

Aller à la page of 20

Summary
  • ADTRAN E220 HFAC HDSL - page 1

    1 61221051L1-5, Issue 1 61221051L1-5A Section 61221051L1-5A Issue 1, April 2000 CLEI # T1L4FFCC_ _ E220 HF AC HDSL / HDSL2 FUSE Alarm Control Unit Installation and Maintenance Trademarks: Any brand names and product names included in this document are trademarks, registered trademarks, or trade names of their respective holders. 1. GENERAL The ADTR ...

  • ADTRAN E220 HFAC HDSL - page 2

    2 61221051L1-5, Issue 1 61221051L1-5A C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. Electrical cable compliance Table 1 shows the Compliance Codes for HFAC. The HFAC complies with the requirements covered under UL 1950 third edition and is intended to be installed in an enclosure with an ...

  • ADTRAN E220 HFAC HDSL - page 3

    3 61221051L1-5, Issue 1 61221051L1-5A Table 2. S1 Switch Options (arrow indicates default setting) Switch Function S1-1 .................................. Errored Seconds Down ................................ Minor Alarm Up (open) ......................... Major Alarm S1-2 .................................. Severely Errored Seconds Down ........... ...

  • ADTRAN E220 HFAC HDSL - page 4

    4 61221051L1-5, Issue 1 61221051L1-5A Table 3. S2 Switch Options (arrow indicates default setting) Switch Function S2-1 ........... S2-2 ............. ES Alarm Threshold Down ......... Down ............ No Alarm Up (open) .. Down ............ 15 Down ......... Up (open) ..... 30 Up (open) .. Up (open) ..... 150 S2-3 ........... S2-4 ............. S ...

  • ADTRAN E220 HFAC HDSL - page 5

    5 61221051L1-5, Issue 1 61221051L1-5A Severely Errored Seconds (SES) Alarm The locations shown in Figure 4 are monitored for Severely Errored Seconds and counts are maintained for each location. If any of these counts exceed the SES programmed threshold (see Tables 1 and 2) an alarm will be generated. This alarm threshold and the alarm type (minor ...

  • ADTRAN E220 HFAC HDSL - page 6

    6 61221051L1-5, Issue 1 61221051L1-5A resulting from blown fuses in the HFAC, HTU-C, or HCOT units, or from communications failure between any HTU-C and the HFAC. Alarm severity and threshold value can be provisioned for the errored second, severely errored second, and unavailable second parameters. An option available on the HFAC Option Setup scre ...

  • ADTRAN E220 HFAC HDSL - page 7

    7 61221051L1-5, Issue 1 61221051L1-5A Figure 6. Control Port Pin Assignments (DCE Configuration) 6 7 8 9 1 2 3 4 5 TXD (TXD to DTE) RXD (TXD from DTE) DTR SGN GND DSR RTS CTS interconnect subsequent shelves. Each shelf controller should be assigned unique sequential shelf addresses. No connection should be made to the RS422 in connector on the shel ...

  • ADTRAN E220 HFAC HDSL - page 8

    8 61221051L1-5, Issue 1 61221051L1-5A technical support phone numbers along with serial numbers, CLEI codes, date of manufacture information for each active HDSL / HDSL2 system element, and if the circuit has an installed HDSL / HDSL2 range extender (HRE / H2R). NOTE The command keys valid for each screen are shown at the bottom of the display. Pre ...

  • ADTRAN E220 HFAC HDSL - page 9

    9 61221051L1-5, Issue 1 61221051L1-5A Figure 8. Main Menu Screen 08/08/70 17:57:06 SHELF ADDRESS = 00 HFAC MAIN MENU 1: SHELF STATUS SUMMARY 2: PERFORMANCE DATA 3: ALARM STATUS 4: LOOPBACK CONTROL 5: ADTRAN INFORMATION 6: TROUBLESHOOTING 7: SELF-TEST OPTIONS 8: PROVISIONING 9: PROTECTION SWITCHING CHOOSE 1-9 : Figure 7. Introductory Menu 08/08/70 1 ...

  • ADTRAN E220 HFAC HDSL - page 10

    10 61221051L1-5, Issue 1 61221051L1-5A Shelf Status Summary Screen The Shelf Status Summary Screen shown in Figure 9 provides a top-level look at the alarm and provisioning of data for the shelf and each circuit within the shelf. HDSL / HDSL2 Status Screen From the Shelf Status Summary Screen, detailed information related to a particular circuit ma ...

  • ADTRAN E220 HFAC HDSL - page 11

    11 61221051L1-5, Issue 1 61221051L1-5A Figures 10 and 10A consolidate current information for the HDSL / HDSL2, DSX-1, and DS1 interfaces. A key to the information provided is found in the center of the screen. Arrows indicate the key applies to both the HTU-C and HTU-R. LOSS Pulse Attenuation Measurement SYNC HDSL Loop 1 and Loop 2 Sync Status ES ...

  • ADTRAN E220 HFAC HDSL - page 12

    12 61221051L1-5, Issue 1 61221051L1-5A Shelf Controller Options From the Shelf Status Summary Screen, all shelf controller options may be reviewed. By typing O at the Shelf Status Summary Screen, the Shelf Options Setup Screen may be accessed. This screen is illustrated in Figure 11 . External DSX-1 or DS1 threshold alarms (ES, SES, UAS) can be ena ...

  • ADTRAN E220 HFAC HDSL - page 13

    13 61221051L1-5, Issue 1 61221051L1-5A Performance History Screen Detailed information concerning 15-minute performance history and 24-hour performance history for any given slot may be viewed by typing the slot number and S from the slot specific Performance Data Screen. The resulting screen is shown in Figure 13, Slot Specific Performance Data Sc ...

  • ADTRAN E220 HFAC HDSL - page 14

    14 61221051L1-5, Issue 1 61221051L1-5A Alarm Status Screen Selection of item 3 from the Main Menu presents the Alarm Status Screen, Figure 14 . This screen is a composite display of all current alarms for each of the 13 slots. Alarm types are indicated by the number 1 for Critical, 2 for Major, and 3 for Minor alarms. A capital A indicates the alar ...

  • ADTRAN E220 HFAC HDSL - page 15

    15 61221051L1-5, Issue 1 61221051L1-5A Loopback Status Summary Screen Item selection 4, Loopback Control, from the Main Menu displays the loopback status information for all of the HTU-C, HRE, and HTU-R units monitored by the HFAC. Loopback Status (On, Off, or Not available) is presented for loopbacks to both the network and the customer at both th ...

  • ADTRAN E220 HFAC HDSL - page 16

    16 61221051L1-5, Issue 1 61221051L1-5A Troubleshooting Screen The Troubleshooting Screen (Main Menu, Item 6) provides a graphical presentation of trouble areas. Different parts of the diagram will be highlighted (on terminals that support reverse video) to indicate the trouble locations. In addition, in-band alarms and indicated problem areas are p ...

  • ADTRAN E220 HFAC HDSL - page 17

    17 61221051L1-5, Issue 1 61221051L1-5A Self-Test Options Screen By selecting item 7 from the Main Menu, the Self- Test Options Screen ( Figure 19 ) is presented. From this screen, a self-test for the HTU-C, HTU-R, and HFAC controller can be initiated. To initiate a self- test, press the desired test number followed by a T . Upon completion of the t ...

  • ADTRAN E220 HFAC HDSL - page 18

    18 61221051L1-5, Issue 1 61221051L1-5A Provisioning Summary Screen Selection of item 8 from the Main Menu supplies provisioning information on individual circuits being accessed by the HFAC. Figure 20 is a slot-specific provisioning screen showing the provision option item, current settings, and hardware settings for that particular circuit. A key ...

  • ADTRAN E220 HFAC HDSL - page 19

    19 61221051L1-5, Issue 1 61221051L1-5A Protection Configuration Screen The protection configuration screens (Figure 21 and 22) provides status and control details for fault protected circuits. NOTE The screens provided below are typical and may vary slightly depending on the hardware installed. For Instance, if HDSL2 H2TU-C equipment is installed, ...

  • ADTRAN E220 HFAC HDSL - page 20

    20 61221051L1-5, Issue 1 61221051L1-5A Power -48 VDC @ 60 mA (maximum) Physical Dimensions: ............. 5.6" high x 1.25" wide x 10.1" deep Weight: ..................... < 1 pound Temperature Operating: ................ -40 ° C to +70 ° C Storage: .................... -40 ° C to +85 ° C Part Number ADTRAN E220 Shelf Plug in, ...

Fabricant ADTRAN Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilADTRAN E220 HFAC HDSL peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques ADTRAN
- manuels d’utilisations E220 HFAC HDSL
- fiches produit ADTRAN
- dépliants
- ou étiquettes-énergie ADTRAN E220 HFAC HDSL
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation ADTRAN E220 HFAC HDSL.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation ADTRAN E220 HFAC HDSL, manuels d’entretien, brefs manuels ou manuels de l’utilisateur ADTRAN E220 HFAC HDSL. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit ADTRAN E220 HFAC HDSL.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil ADTRAN E220 HFAC HDSL, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser ADTRAN E220 HFAC HDSL par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs ADTRAN E220 HFAC HDSL.

Le manuel d’utilisation complet ADTRAN, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel ADTRAN E220 HFAC HDSL - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières ADTRAN E220 HFAC HDSL, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lADTRAN E220 HFAC HDSL qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil ADTRAN E220 HFAC HDSL - qui devraient nous aider dans les premières étapes lors de l'utilisation ADTRAN E220 HFAC HDSL
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de ADTRAN E220 HFAC HDSL
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service ADTRAN E220 HFAC HDSL dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de ADTRAN E220 HFAC HDSL?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec ADTRAN E220 HFAC HDSL, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec ADTRAN E220 HFAC HDSL il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)