    1 61221051L1-5, Issue 1 61221051L1-5A Section 61221051L1-5A Issue 1, April 2000 CLEI # T1L4FFCC_ _ E220 HF AC HDSL / HDSL2 FUSE Alarm Control Unit Installation and Maintenance Trademarks: Any brand names and product names included in this document are trademarks, registered trademarks, or trade names of their respective holders. 1. GENERAL The ADTR ...

  • ADTRAN E220 HFAC HDSL - page 2

    2 61221051L1-5, Issue 1 61221051L1-5A C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. Electrical cable compliance Table 1 shows the Compliance Codes for HFAC. The HFAC complies with the requirements covered under UL 1950 third edition and is intended to be installed in an enclosure with an ...

  • ADTRAN E220 HFAC HDSL - page 3

    3 61221051L1-5, Issue 1 61221051L1-5A Table 2. S1 Switch Options (arrow indicates default setting) Switch Function S1-1 .................................. Errored Seconds Down ................................ Minor Alarm Up (open) ......................... Major Alarm S1-2 .................................. Severely Errored Seconds Down ........... ...

  • ADTRAN E220 HFAC HDSL - page 4

    4 61221051L1-5, Issue 1 61221051L1-5A Table 3. S2 Switch Options (arrow indicates default setting) Switch Function S2-1 ........... S2-2 ............. ES Alarm Threshold Down ......... Down ............ No Alarm Up (open) .. Down ............ 15 Down ......... Up (open) ..... 30 Up (open) .. Up (open) ..... 150 S2-3 ........... S2-4 ............. S ...

  • ADTRAN E220 HFAC HDSL - page 5

    5 61221051L1-5, Issue 1 61221051L1-5A Severely Errored Seconds (SES) Alarm The locations shown in Figure 4 are monitored for Severely Errored Seconds and counts are maintained for each location. If any of these counts exceed the SES programmed threshold (see Tables 1 and 2) an alarm will be generated. This alarm threshold and the alarm type (minor ...

  • ADTRAN E220 HFAC HDSL - page 6

    6 61221051L1-5, Issue 1 61221051L1-5A resulting from blown fuses in the HFAC, HTU-C, or HCOT units, or from communications failure between any HTU-C and the HFAC. Alarm severity and threshold value can be provisioned for the errored second, severely errored second, and unavailable second parameters. An option available on the HFAC Option Setup scre ...

  • ADTRAN E220 HFAC HDSL - page 7

    7 61221051L1-5, Issue 1 61221051L1-5A Figure 6. Control Port Pin Assignments (DCE Configuration) 6 7 8 9 1 2 3 4 5 TXD (TXD to DTE) RXD (TXD from DTE) DTR SGN GND DSR RTS CTS interconnect subsequent shelves. Each shelf controller should be assigned unique sequential shelf addresses. No connection should be made to the RS422 in connector on the shel ...

  • ADTRAN E220 HFAC HDSL - page 8

    8 61221051L1-5, Issue 1 61221051L1-5A technical support phone numbers along with serial numbers, CLEI codes, date of manufacture information for each active HDSL / HDSL2 system element, and if the circuit has an installed HDSL / HDSL2 range extender (HRE / H2R). NOTE The command keys valid for each screen are shown at the bottom of the display. Pre ...

  • ADTRAN E220 HFAC HDSL - page 9

    9 61221051L1-5, Issue 1 61221051L1-5A Figure 8. Main Menu Screen 08/08/70 17:57:06 SHELF ADDRESS = 00 HFAC MAIN MENU 1: SHELF STATUS SUMMARY 2: PERFORMANCE DATA 3: ALARM STATUS 4: LOOPBACK CONTROL 5: ADTRAN INFORMATION 6: TROUBLESHOOTING 7: SELF-TEST OPTIONS 8: PROVISIONING 9: PROTECTION SWITCHING CHOOSE 1-9 : Figure 7. Introductory Menu 08/08/70 1 ...

  • ADTRAN E220 HFAC HDSL - page 10

    10 61221051L1-5, Issue 1 61221051L1-5A Shelf Status Summary Screen The Shelf Status Summary Screen shown in Figure 9 provides a top-level look at the alarm and provisioning of data for the shelf and each circuit within the shelf. HDSL / HDSL2 Status Screen From the Shelf Status Summary Screen, detailed information related to a particular circuit ma ...

  • ADTRAN E220 HFAC HDSL - page 11

    11 61221051L1-5, Issue 1 61221051L1-5A Figures 10 and 10A consolidate current information for the HDSL / HDSL2, DSX-1, and DS1 interfaces. A key to the information provided is found in the center of the screen. Arrows indicate the key applies to both the HTU-C and HTU-R. LOSS Pulse Attenuation Measurement SYNC HDSL Loop 1 and Loop 2 Sync Status ES ...

  • ADTRAN E220 HFAC HDSL - page 12

    12 61221051L1-5, Issue 1 61221051L1-5A Shelf Controller Options From the Shelf Status Summary Screen, all shelf controller options may be reviewed. By typing O at the Shelf Status Summary Screen, the Shelf Options Setup Screen may be accessed. This screen is illustrated in Figure 11 . External DSX-1 or DS1 threshold alarms (ES, SES, UAS) can be ena ...

  • ADTRAN E220 HFAC HDSL - page 13

    13 61221051L1-5, Issue 1 61221051L1-5A Performance History Screen Detailed information concerning 15-minute performance history and 24-hour performance history for any given slot may be viewed by typing the slot number and S from the slot specific Performance Data Screen. The resulting screen is shown in Figure 13, Slot Specific Performance Data Sc ...

  • ADTRAN E220 HFAC HDSL - page 14

    14 61221051L1-5, Issue 1 61221051L1-5A Alarm Status Screen Selection of item 3 from the Main Menu presents the Alarm Status Screen, Figure 14 . This screen is a composite display of all current alarms for each of the 13 slots. Alarm types are indicated by the number 1 for Critical, 2 for Major, and 3 for Minor alarms. A capital A indicates the alar ...

  • ADTRAN E220 HFAC HDSL - page 15

    15 61221051L1-5, Issue 1 61221051L1-5A Loopback Status Summary Screen Item selection 4, Loopback Control, from the Main Menu displays the loopback status information for all of the HTU-C, HRE, and HTU-R units monitored by the HFAC. Loopback Status (On, Off, or Not available) is presented for loopbacks to both the network and the customer at both th ...

  • ADTRAN E220 HFAC HDSL - page 16

    16 61221051L1-5, Issue 1 61221051L1-5A Troubleshooting Screen The Troubleshooting Screen (Main Menu, Item 6) provides a graphical presentation of trouble areas. Different parts of the diagram will be highlighted (on terminals that support reverse video) to indicate the trouble locations. In addition, in-band alarms and indicated problem areas are p ...

  • ADTRAN E220 HFAC HDSL - page 17

    17 61221051L1-5, Issue 1 61221051L1-5A Self-Test Options Screen By selecting item 7 from the Main Menu, the Self- Test Options Screen ( Figure 19 ) is presented. From this screen, a self-test for the HTU-C, HTU-R, and HFAC controller can be initiated. To initiate a self- test, press the desired test number followed by a T . Upon completion of the t ...

  • ADTRAN E220 HFAC HDSL - page 18

    18 61221051L1-5, Issue 1 61221051L1-5A Provisioning Summary Screen Selection of item 8 from the Main Menu supplies provisioning information on individual circuits being accessed by the HFAC. Figure 20 is a slot-specific provisioning screen showing the provision option item, current settings, and hardware settings for that particular circuit. A key ...

  • ADTRAN E220 HFAC HDSL - page 19

    19 61221051L1-5, Issue 1 61221051L1-5A Protection Configuration Screen The protection configuration screens (Figure 21 and 22) provides status and control details for fault protected circuits. NOTE The screens provided below are typical and may vary slightly depending on the hardware installed. For Instance, if HDSL2 H2TU-C equipment is installed, ...

  • ADTRAN E220 HFAC HDSL - page 20

    20 61221051L1-5, Issue 1 61221051L1-5A Power -48 VDC @ 60 mA (maximum) Physical Dimensions: ............. 5.6" high x 1.25" wide x 10.1" deep Weight: ..................... < 1 pound Temperature Operating: ................ -40 ° C to +70 ° C Storage: .................... -40 ° C to +85 ° C Part Number ADTRAN E220 Shelf Plug in, ...

Fabbricante ADTRAN Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoADTRAN E220 HFAC HDSL possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici ADTRAN
- manuali per l’uso E220 HFAC HDSL
- schede prodotto ADTRAN
- opuscoli
- o etichette energetiche ADTRAN E220 HFAC HDSL
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso ADTRAN E220 HFAC HDSL.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione ADTRAN E220 HFAC HDSL, manuali di manutenzione, brevi manuali o manuali utente ADTRAN E220 HFAC HDSL. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto ADTRAN E220 HFAC HDSL.

Manuali per l’uso simili

Manuale completo del dispositivo ADTRAN E220 HFAC HDSL, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare ADTRAN E220 HFAC HDSL dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti ADTRAN E220 HFAC HDSL.

Il manuale per l’uso completo ADTRAN, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale ADTRAN E220 HFAC HDSL - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice ADTRAN E220 HFAC HDSL, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per ADTRAN E220 HFAC HDSL che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo ADTRAN E220 HFAC HDSL - che ci dovrebbe aiutare nei primi passi durante l'uso ADTRAN E220 HFAC HDSL
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del ADTRAN E220 HFAC HDSL
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio ADTRAN E220 HFAC HDSL in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su ADTRAN E220 HFAC HDSL?

Utilizza il modulo sottostante

Se non hai risolto il problema con ADTRAN E220 HFAC HDSL con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con ADTRAN E220 HFAC HDSL è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)