Manuel d’utilisation Sharper Image OQ234

22 pages 0.39 mb
Télécharger

Aller à la page of 22

Summary
  • Sharper Image OQ234 - page 1

    Cable -F ree ™ In/Out Remote Thermometer with T rend Chart OQ234 Instructions Read and save these instructions. ...

  • Sharper Image OQ234 - page 2

    Dear Sharper Image Customer , Thank you for your purchase of a Sharper Image product. W e appreciate your business very much. Please accept my personal assurance of your complete satisfaction with this product’ s quality and perfor mance. W e offer generous return privileges and excellent warranties on all our products. For more than 25 years, Th ...

  • Sharper Image OQ234 - page 3

    • Do not immerse the unit in water . • Do not clean the unit with abrasive or corrosive material. • Do not subject the unit to excessive force, shock, dust, temper- ature or humidity . • Do not tamper with the unit’s internal components. Doing so will invalidate the warranty on the unit and may cause unnec- essary damage. • Only use fre ...

  • Sharper Image OQ234 - page 4

    Battery Installation Remote Units: • Unscrew battery compartment cover for remote units first. • Designate a channel number (1, 2, 3) for each remote on the Channel Slide Switch; choose ˚F or ˚C temperature display unit on the ˚F/˚C Switch. • Insert two AAA (UM-4) batteries (included) into each battery compartment as specified. Ensure pro ...

  • Sharper Image OQ234 - page 5

    temperature samplings at roughly 30-second intervals from the three remote units. If no signal is received, blanks will be displayed. Press the main unit’s CHANNEL and MEMORY simultaneously to enforce another search, or to synchronize the transmission and reception of the remote and main units if you find discrepancies in the temperatures shown. ...

  • Sharper Image OQ234 - page 6

    Main Features A. OUTDOOR TEMPERA TURE - Displays current temperature, remote sensor unit. B. TEMPERA TURE TREND CHART - Outdoor CHANNEL 1 tem- perature variance display , last 12 hours. INSTRUCTIONS FOR USE G F E A N L K M H I J D B C ...

  • Sharper Image OQ234 - page 7

    C. INDOOR TEMPERA TURE - Shows the temperature collected indoors. D. ICE W ARNING ICON - Lights up when the ice warning func- tion is active. E. CHANNEL BUTT ON - Sets the remote sensor channel. F. MEMORY BUTT ON - T oggles between current, maximum and minimum temperatures. G. CLEAR BUTT ON - Erases memory data. H. RESET BUTT ON - Returns all setti ...

  • Sharper Image OQ234 - page 8

    A. LCD - Displays the current temperature monitored by the remote unit. B. LED INDICA T OR - Flashes when the remote unit transmits a reading . C. °F/°C SLIDE SWITCH - Selects between degrees F ahrenheit (°F) and Centigrade (°C). Main Features: Remote Unit G F E A H D B C ...

  • Sharper Image OQ234 - page 9

    D. CHANNEL SLIDE SWITCH - Designates the remote unit Channel 1, Channel 2 or Channel 3. E. RESET BUTT ON - Returns all settings to default values. F. BA TTERY COMP ARTMENT - Accommodates two UM-4 or AAA - size batteries. G. W ALL -MOUNT HOLDER - Supports the remote unit when wall-mounted. H. REMOV ABLE T ABLE ST AND - F or standing the remote unit ...

  • Sharper Image OQ234 - page 10

    1. Remove the screws on the battery compartment. 2. Select the channel number on the CHANNEL slide switch. 3. Select the temperature display unit on the °F/°C slide switch. 4. Insert two UM-4 or AAA - size batteries. 5. Replace the battery compartment door and secure the screws. Replace the batteries when the low-battery indicator of the par- tic ...

  • Sharper Image OQ234 - page 11

    Note: Once a channel is assigned to a unit, you can change it only by removing the batteries and repeating the above procedure. Battery Installation: Main Unit 1. Slide the battery compartment door open. 2. Insert two UM-3 or AA - size batteries. 3. Replace the battery compartment door . Battery and Channel Installation: Remote Unit ...

  • Sharper Image OQ234 - page 12

    4. Flip the table stand open and press the RESET button with a blunt stylus. This ensures easier synchronization between the transmission and reception of signals. Replace the batteries when the indicator of the indoor tem- perature lights up. Getting Started Once batteries are in place for the remote units, they will start transmitting samplings a ...

  • Sharper Image OQ234 - page 13

    If no signals are received, blanks are displayed. Press CHANNEL and MEMORY simultaneously to enforce another search. This is useful in synchronizing the transmission and reception of the remote and main units. Repeat this step whenever you find discrepancies between the reading shown on the main unit and the reading shown on the respective remote u ...

  • Sharper Image OQ234 - page 14

    The indoor temperature is shown on the bottom line of the dis- play . T emperature readings, received from a remote sensor , are displayed on the top line of the unit. Press CHANNEL to change from one channel to the next. If more than one remote sensor is being used, the unit can auto- matically scan all three of the outdoor channels. To use the au ...

  • Sharper Image OQ234 - page 15

    The kinetic wave display on the channel icon indicates the status of reception. The unit is in searching mode T emperature readings are securely registered No signals If no readings are received from one particular channel for more than two minutes, blanks are displayed until further readings are successfully searched. T o enforce an immediate sear ...

  • Sharper Image OQ234 - page 16

    The maximum and minimum recorded indoor temperatures and those of each channel are automatically stored in memory . T o display them: 1. Press CHANNEL to locate the desired channel. 2. Press MEMORY to rotate through the maximum (MAX), mini- mum (MIN) and current temperatures. Indoor temperature readings are displayed. To clear the memory of a parti ...

  • Sharper Image OQ234 - page 17

    The temperature variance for CHANNEL 1 for the past 12 hours is automatically scanned on the screen in six equal columns. The variance is represented in rows of degrees C above or below the current temperature at 0 Hr (current time) and 0°C (no variance). Ice W arning The ice warning is selected on the ICE W ARNING slide switch located on the main ...

  • Sharper Image OQ234 - page 18

    To deactivate the ice warning function, slide the ICE W ARNING switch to OFF . T able Stand and W all Mount To place the main unit on a flat surface, flip open the table stand. Mount the unit on a wall using the recessed hole. Ice W arning ...

  • Sharper Image OQ234 - page 19

    The remote unit comes with a removable table stand and a wall- mount holder . Reset Button The RESET button is used to enhance synchronization of signals after battery replacement or when the unit malfunctions. Use a blunt stylus to hold the RESET button down. All settings will return to their default values. T able Stand and W all Mount ...

  • Sharper Image OQ234 - page 20

    T emperature Measurement Main Unit Indoor T emperature Measurement Displayed IN temperature range 14.0°F to 158.0°F (-9.9°C to +70.0°C) Proposed operating range 23.0°F to 122.0°F (-5.0°C to +50.0°C) T emperature resolution 0.2°F (0.1°C) T emperature scale <-7°C to >7°C Ice W arning Function -2°C to +3°C Channel 1 remote sensor 2 ...

  • Sharper Image OQ234 - page 21

    Number of remote units Maximum of three RF transmission range 100 meters T emperature sensing cycle 30 seconds User-selectable °F and °C P ower Main unit Use 2 UM-3 or AA 1.5V alkaline battery Remote unit Use 2 UM-4 or AAA 1.5V alkaline battery W eight Main unit 200 g (without battery) Remote sensing unit 87 g (without battery) Dimension Main uni ...

  • Sharper Image OQ234 - page 22

    What Is Covered This warranty covers any defects in materials or workmanship, with the exceptions stated below . How Long Coverage Lasts This warranty runs for 90 days from the date of original purchase. What Is Not Covered This warranty does not cover damage caused by misuse or use other than as intended and described in the product instruction ma ...

Fabricant Sharper Image Catégorie Thermostat

Les documents que nous recevons du fabricant de l'appareilSharper Image OQ234 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Sharper Image
- manuels d’utilisations OQ234
- fiches produit Sharper Image
- dépliants
- ou étiquettes-énergie Sharper Image OQ234
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Sharper Image OQ234.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Sharper Image OQ234, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Sharper Image OQ234. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Sharper Image OQ234.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Sharper Image OQ234, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Sharper Image OQ234 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Sharper Image OQ234.

Le manuel d’utilisation complet Sharper Image, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Sharper Image OQ234 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Sharper Image OQ234, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSharper Image OQ234 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Sharper Image OQ234 - qui devraient nous aider dans les premières étapes lors de l'utilisation Sharper Image OQ234
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Sharper Image OQ234
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Sharper Image OQ234 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Sharper Image OQ234?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Sharper Image OQ234, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Sharper Image OQ234 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)