Sharper Image OQ234の取扱説明書

22ページ 0.39 mb
ダウンロード

ページに移動 of 22

Summary
  • Sharper Image OQ234 - page 1

    Cable -F ree ™ In/Out Remote Thermometer with T rend Chart OQ234 Instructions Read and save these instructions. ...

  • Sharper Image OQ234 - page 2

    Dear Sharper Image Customer , Thank you for your purchase of a Sharper Image product. W e appreciate your business very much. Please accept my personal assurance of your complete satisfaction with this product’ s quality and perfor mance. W e offer generous return privileges and excellent warranties on all our products. For more than 25 years, Th ...

  • Sharper Image OQ234 - page 3

    • Do not immerse the unit in water . • Do not clean the unit with abrasive or corrosive material. • Do not subject the unit to excessive force, shock, dust, temper- ature or humidity . • Do not tamper with the unit’s internal components. Doing so will invalidate the warranty on the unit and may cause unnec- essary damage. • Only use fre ...

  • Sharper Image OQ234 - page 4

    Battery Installation Remote Units: • Unscrew battery compartment cover for remote units first. • Designate a channel number (1, 2, 3) for each remote on the Channel Slide Switch; choose ˚F or ˚C temperature display unit on the ˚F/˚C Switch. • Insert two AAA (UM-4) batteries (included) into each battery compartment as specified. Ensure pro ...

  • Sharper Image OQ234 - page 5

    temperature samplings at roughly 30-second intervals from the three remote units. If no signal is received, blanks will be displayed. Press the main unit’s CHANNEL and MEMORY simultaneously to enforce another search, or to synchronize the transmission and reception of the remote and main units if you find discrepancies in the temperatures shown. ...

  • Sharper Image OQ234 - page 6

    Main Features A. OUTDOOR TEMPERA TURE - Displays current temperature, remote sensor unit. B. TEMPERA TURE TREND CHART - Outdoor CHANNEL 1 tem- perature variance display , last 12 hours. INSTRUCTIONS FOR USE G F E A N L K M H I J D B C ...

  • Sharper Image OQ234 - page 7

    C. INDOOR TEMPERA TURE - Shows the temperature collected indoors. D. ICE W ARNING ICON - Lights up when the ice warning func- tion is active. E. CHANNEL BUTT ON - Sets the remote sensor channel. F. MEMORY BUTT ON - T oggles between current, maximum and minimum temperatures. G. CLEAR BUTT ON - Erases memory data. H. RESET BUTT ON - Returns all setti ...

  • Sharper Image OQ234 - page 8

    A. LCD - Displays the current temperature monitored by the remote unit. B. LED INDICA T OR - Flashes when the remote unit transmits a reading . C. °F/°C SLIDE SWITCH - Selects between degrees F ahrenheit (°F) and Centigrade (°C). Main Features: Remote Unit G F E A H D B C ...

  • Sharper Image OQ234 - page 9

    D. CHANNEL SLIDE SWITCH - Designates the remote unit Channel 1, Channel 2 or Channel 3. E. RESET BUTT ON - Returns all settings to default values. F. BA TTERY COMP ARTMENT - Accommodates two UM-4 or AAA - size batteries. G. W ALL -MOUNT HOLDER - Supports the remote unit when wall-mounted. H. REMOV ABLE T ABLE ST AND - F or standing the remote unit ...

  • Sharper Image OQ234 - page 10

    1. Remove the screws on the battery compartment. 2. Select the channel number on the CHANNEL slide switch. 3. Select the temperature display unit on the °F/°C slide switch. 4. Insert two UM-4 or AAA - size batteries. 5. Replace the battery compartment door and secure the screws. Replace the batteries when the low-battery indicator of the par- tic ...

  • Sharper Image OQ234 - page 11

    Note: Once a channel is assigned to a unit, you can change it only by removing the batteries and repeating the above procedure. Battery Installation: Main Unit 1. Slide the battery compartment door open. 2. Insert two UM-3 or AA - size batteries. 3. Replace the battery compartment door . Battery and Channel Installation: Remote Unit ...

  • Sharper Image OQ234 - page 12

    4. Flip the table stand open and press the RESET button with a blunt stylus. This ensures easier synchronization between the transmission and reception of signals. Replace the batteries when the indicator of the indoor tem- perature lights up. Getting Started Once batteries are in place for the remote units, they will start transmitting samplings a ...

  • Sharper Image OQ234 - page 13

    If no signals are received, blanks are displayed. Press CHANNEL and MEMORY simultaneously to enforce another search. This is useful in synchronizing the transmission and reception of the remote and main units. Repeat this step whenever you find discrepancies between the reading shown on the main unit and the reading shown on the respective remote u ...

  • Sharper Image OQ234 - page 14

    The indoor temperature is shown on the bottom line of the dis- play . T emperature readings, received from a remote sensor , are displayed on the top line of the unit. Press CHANNEL to change from one channel to the next. If more than one remote sensor is being used, the unit can auto- matically scan all three of the outdoor channels. To use the au ...

  • Sharper Image OQ234 - page 15

    The kinetic wave display on the channel icon indicates the status of reception. The unit is in searching mode T emperature readings are securely registered No signals If no readings are received from one particular channel for more than two minutes, blanks are displayed until further readings are successfully searched. T o enforce an immediate sear ...

  • Sharper Image OQ234 - page 16

    The maximum and minimum recorded indoor temperatures and those of each channel are automatically stored in memory . T o display them: 1. Press CHANNEL to locate the desired channel. 2. Press MEMORY to rotate through the maximum (MAX), mini- mum (MIN) and current temperatures. Indoor temperature readings are displayed. To clear the memory of a parti ...

  • Sharper Image OQ234 - page 17

    The temperature variance for CHANNEL 1 for the past 12 hours is automatically scanned on the screen in six equal columns. The variance is represented in rows of degrees C above or below the current temperature at 0 Hr (current time) and 0°C (no variance). Ice W arning The ice warning is selected on the ICE W ARNING slide switch located on the main ...

  • Sharper Image OQ234 - page 18

    To deactivate the ice warning function, slide the ICE W ARNING switch to OFF . T able Stand and W all Mount To place the main unit on a flat surface, flip open the table stand. Mount the unit on a wall using the recessed hole. Ice W arning ...

  • Sharper Image OQ234 - page 19

    The remote unit comes with a removable table stand and a wall- mount holder . Reset Button The RESET button is used to enhance synchronization of signals after battery replacement or when the unit malfunctions. Use a blunt stylus to hold the RESET button down. All settings will return to their default values. T able Stand and W all Mount ...

  • Sharper Image OQ234 - page 20

    T emperature Measurement Main Unit Indoor T emperature Measurement Displayed IN temperature range 14.0°F to 158.0°F (-9.9°C to +70.0°C) Proposed operating range 23.0°F to 122.0°F (-5.0°C to +50.0°C) T emperature resolution 0.2°F (0.1°C) T emperature scale <-7°C to >7°C Ice W arning Function -2°C to +3°C Channel 1 remote sensor 2 ...

  • Sharper Image OQ234 - page 21

    Number of remote units Maximum of three RF transmission range 100 meters T emperature sensing cycle 30 seconds User-selectable °F and °C P ower Main unit Use 2 UM-3 or AA 1.5V alkaline battery Remote unit Use 2 UM-4 or AAA 1.5V alkaline battery W eight Main unit 200 g (without battery) Remote sensing unit 87 g (without battery) Dimension Main uni ...

  • Sharper Image OQ234 - page 22

    What Is Covered This warranty covers any defects in materials or workmanship, with the exceptions stated below . How Long Coverage Lasts This warranty runs for 90 days from the date of original purchase. What Is Not Covered This warranty does not cover damage caused by misuse or use other than as intended and described in the product instruction ma ...

メーカー Sharper Image カテゴリー Thermostat

Sharper Image OQ234のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- OQ234の取扱説明書
- Sharper Imageの製品カード
- パンフレット
- またはSharper Image OQ234の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Sharper Image OQ234の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Sharper Image OQ234の取り付け説明書、サービスマニュアル、簡易説明書、またはSharper Image OQ234のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Sharper Image OQ234の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Sharper Image OQ234デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSharper Image OQ234を使用するのを助ける技術的文書のことです。説明書は通常、全てのSharper Image OQ234ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Sharper Imageの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Sharper Image OQ234の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSharper Image OQ234の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Sharper Image OQ234に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Sharper Image OQ234デバイスの基本機能を使うにあたってのヒント。 Sharper Image OQ234のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Sharper Image OQ234に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSharper Image OQ234のメーカー/サービスへの連絡先に関する情報。

Sharper Image OQ234についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSharper Image OQ234の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSharper Image OQ234で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)