Manuel d’utilisation Therma-Tru Light Commercial Doors and Frames

13 pages 0.9 mb
Télécharger

Aller à la page of 13

Summary
  • Therma-Tru Light Commercial Doors and Frames - page 1

    Therma-T ru ® Light Commercial/Multi-Family - Doors and Frames 1 • Material shown on these dra wings will be fabricated only after formal approv al by the arc hitect, receipt of approv al hardware sc hedule, and all necessary hardw are templates. • All frames shall be shipped “knoc ked-down” unless otherwise specied. • All frames and ...

  • Therma-Tru Light Commercial Doors and Frames - page 2

    2 REMARKS WIDTH HEIGHT JOB NUMBER PROJECT SHEET NUMBER OF LOCATION LOCK CLOSER FLUSH BOL TS HRDWR. SET/ HDG. GAUGE SHEET ELEV . LABEL HINGE JAMB DEPTH OVERALL HEIGHT ANCHOR DOOR CONSTR. DOOR OPENING DOOR THICK. SHEET ELEV . SHEET SECT . ITEM QUANTITY ARCH MARK FROM TO SWING FRAME CONSTR. GAUGE LOCATION FRAME DATA DOOR DATA HARDWARE Therma-T ru ® L ...

  • Therma-Tru Light Commercial Doors and Frames - page 3

    3 DOOR ELEV A TIONS - FLUSH - LITED DOOR ELEV A TIONS - EMBOSSED - OP AQUE Therma-T ru ® Light Commercial/Multi-Family - 22-Gauge & 24-Gauge Steel Doors EXPOSED GLASS SIZE: 3” x 33” EXPOSED GLASS SIZE: 4” x 25” EXPOSED GLASS SIZE: 5” x 20” 3” 4” 5” 33” 25” 20” EXPOSED GLASS SIZE: 10” x 10” EXPOSED GLASS SIZE: 22” ...

  • Therma-Tru Light Commercial Doors and Frames - page 4

    4 Therma-T ru ® Light Commercial/Multi-Family - FG Doors DOOR ELEV A TIONS - SMOO TH DOOR ELEV A TIONS - GRAINED STYLE# FCF160 STYLE# FCF140 STYLE# FCF100 STYLE# SSF960 STYLE# SSF200 STYLE# SSF160 STYLE# SSF100 ...

  • Therma-Tru Light Commercial Doors and Frames - page 5

    5 Therma-T ru ® Light Commercial/Multi-Family - Standard Hardware Preps. STEEL DEADBOL T PREP: ST AMPED 1 1/8" x 2 3/4" OPTIONAL DEADBOL T PREP FOR STEEL FRAMES. AV AILABLE WITH ADJUST A-FIT , ADJUST A-TRIM, HOLLOW MET AL, SECURA-FIT & VIST A III FRAMES. STEEL DEADBOL T PREP ST AMPED 1 1/18" x 2 3/4" OPTIONAL DEADBOL T PREP ...

  • Therma-Tru Light Commercial Doors and Frames - page 6

    6 Therma-T ru ® Light Commercial/Multi-Family - Hardware Locations NOMINAL 2-0 2-4 2-6 2-8 2-10 3-0 3-6 ACTUAL 23 11/16" 27 11/16" 29 11/16" 31 11/16" 33 11/16" 35 11/16" 41 11/16" NOMINAL 6-8 7-0 8-0 ACTUAL 78 5/8" 82 1/8" 93" MORTISE PREP 45 1/4" 45 1/4" 59 5/8" CYLINDRICAL PREP 44 ...

  • Therma-Tru Light Commercial Doors and Frames - page 7

    7 Therma-T ru ® Light Commercial/Multi-Family - Custom Elevations/Applications JOB NUMBER PROJECT LOCATION SHEET NUMBER OF ...

  • Therma-Tru Light Commercial Doors and Frames - page 8

    8 Therma-T ru ® Light Commercial/Multi-Family - Adjusta-Fit ® Frames - Single 2-0 x 6-8 2-4 x 6-8 2-6 x 6-8 2-8 x 6-8 SPRING LOADED 2-10 x 6-8 BALL BEARING 3-0 x 6-8 3-6 x 6-8 4 7/8" ANSI (STD) 2-0 x 7-0 2-4 x 7-0 2-6 x 7-0 2-8 x 7-0 2-10 x 7-0 3-0 x 7-0 3-6 x 7-0 83 1/4" 83 1/4" 83 1/4" 83 1/4" 83 1/4" 83 5/8" ...

  • Therma-Tru Light Commercial Doors and Frames - page 9

    9 Therma-T ru ® Light Commercial/Multi-Family - Adjusta-Fit ® Frames - Double FRAME DET AIL 4-0 = 48 17/32" 5-0 = 60 17/32" 5-4 = 64 17/32" 6-0 = 72 17/32" 4-0 = 49 1/2" 5-0 = 61 1/2" 5-4 = 65 1/2" 6-0 = 73 1/2" ADJUST A-FIT FRAME HINGE JAMB 4" x 4" HINGE ADJUST A-FIT FRAME INACTIVE HINGE JAMB 4&q ...

  • Therma-Tru Light Commercial Doors and Frames - page 10

    10 Therma-T ru ® Light Commercial/Multi-Family - Adjusta-T rim ® Frames - Single FRAME DET AIL EXISTING WALL ADJUST A-TRIM CLOSURE JAMB COMPRESSION WEA THERSTRIPPING COMPRESSION WEA THERSTRIPPING STEEL ENTRANCE DOOR 2-0 = 24" 2-4 = 28" 2-6 = 30" 2-8 = 32" 2-10 = 34" 3-0 = 36" 3-6 = 42" 2-10 = 35" 3-0 = 37&q ...

  • Therma-Tru Light Commercial Doors and Frames - page 11

    11 Therma-T ru ® Light Commercial/Multi-Family - Adjusta-T rim ® Frames - Double FRAME DET AIL 4-0 = 48 17/32" 5-0 = 60 17/32" 5-4 = 64 17/32" 6-0 = 72 17/32" 4-0 = 49" 5-0 = 61" 5-4 = 65" 6-0 = 73" WOOD SP ACER ADJUST A-TRIM FRAME HINGE JAMB 4" x 4" HINGE ADJUST A-TRIM FRAME INACTIVE HINGE JAMB 4 ...

  • Therma-Tru Light Commercial Doors and Frames - page 12

    12 Therma-T ru ® Light Commercial/Multi-Family - Secura-Fit ® Frames - Single 2-0 x 6-8 2-4 x 6-8 2-6 x 6-8 2-8 x 6-8 SPRING LOADED 2-10 x 6-8 BALL BEARING 3-0 x 6-8 2-0 x 7-0 T-STRIKE (STD) 2-4 x 7-0 T-STRIKE w/ DEADBOLT 2-6 x 7-0 2-8 x 7-0 2-10 x 7-0 3-0 x 7-0 JOB NUMBER PROJECT LOCATION NOMINAL ROUGH ROUGH FRAME OPENING OPENING OPENING WIDTH H ...

  • Therma-Tru Light Commercial Doors and Frames - page 13

    13 Therma-T ru ® Light Commercial/Multi-Family - Secura-Fit ® Frames - Double 4-0 x 6-8 5-0 x 6-8 5-4 x 6-8 6-0 x 6-8 SPRING LOADED 4-0 x 7-0 BALL BEARING 5-0 x 7-0 5-0 x 7-0 T-STRIKE (STD) 6-0 x 7-0 T-STRIKE w/ DEADBOLT JOB NUMBER PROJECT LOCATION NOMINAL ROUGH ROUGH FRAME OPENING OPENING OPENING WIDTH HEIGHT 47 3/4" - 48" 79 7/8" ...

Fabricant Therma-Tru Catégorie Door

Les documents que nous recevons du fabricant de l'appareilTherma-Tru Light Commercial Doors and Frames peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Therma-Tru
- manuels d’utilisations Light Commercial Doors and Frames
- fiches produit Therma-Tru
- dépliants
- ou étiquettes-énergie Therma-Tru Light Commercial Doors and Frames
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Therma-Tru Light Commercial Doors and Frames.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Therma-Tru Light Commercial Doors and Frames, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Therma-Tru Light Commercial Doors and Frames. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Therma-Tru Light Commercial Doors and Frames.

Manuel d’utilisation complet de l’appareil Therma-Tru Light Commercial Doors and Frames, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Therma-Tru Light Commercial Doors and Frames par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Therma-Tru Light Commercial Doors and Frames.

Le manuel d’utilisation complet Therma-Tru, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Therma-Tru Light Commercial Doors and Frames - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Therma-Tru Light Commercial Doors and Frames, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lTherma-Tru Light Commercial Doors and Frames qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Therma-Tru Light Commercial Doors and Frames - qui devraient nous aider dans les premières étapes lors de l'utilisation Therma-Tru Light Commercial Doors and Frames
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Therma-Tru Light Commercial Doors and Frames
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Therma-Tru Light Commercial Doors and Frames dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Therma-Tru Light Commercial Doors and Frames?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Therma-Tru Light Commercial Doors and Frames, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Therma-Tru Light Commercial Doors and Frames il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)