  • Therma-Tru Light Commercial Doors and Frames - page 1

    Therma-T ru ® Light Commercial/Multi-Family - Doors and Frames 1 • Material shown on these dra wings will be fabricated only after formal approv al by the arc hitect, receipt of approv al hardware sc hedule, and all necessary hardw are templates. • All frames shall be shipped “knoc ked-down” unless otherwise specied. • All frames and ...

  • Therma-Tru Light Commercial Doors and Frames - page 2

    2 REMARKS WIDTH HEIGHT JOB NUMBER PROJECT SHEET NUMBER OF LOCATION LOCK CLOSER FLUSH BOL TS HRDWR. SET/ HDG. GAUGE SHEET ELEV . LABEL HINGE JAMB DEPTH OVERALL HEIGHT ANCHOR DOOR CONSTR. DOOR OPENING DOOR THICK. SHEET ELEV . SHEET SECT . ITEM QUANTITY ARCH MARK FROM TO SWING FRAME CONSTR. GAUGE LOCATION FRAME DATA DOOR DATA HARDWARE Therma-T ru ® L ...

  • Therma-Tru Light Commercial Doors and Frames - page 3

    3 DOOR ELEV A TIONS - FLUSH - LITED DOOR ELEV A TIONS - EMBOSSED - OP AQUE Therma-T ru ® Light Commercial/Multi-Family - 22-Gauge & 24-Gauge Steel Doors EXPOSED GLASS SIZE: 3” x 33” EXPOSED GLASS SIZE: 4” x 25” EXPOSED GLASS SIZE: 5” x 20” 3” 4” 5” 33” 25” 20” EXPOSED GLASS SIZE: 10” x 10” EXPOSED GLASS SIZE: 22” ...

  • Therma-Tru Light Commercial Doors and Frames - page 4

    4 Therma-T ru ® Light Commercial/Multi-Family - FG Doors DOOR ELEV A TIONS - SMOO TH DOOR ELEV A TIONS - GRAINED STYLE# FCF160 STYLE# FCF140 STYLE# FCF100 STYLE# SSF960 STYLE# SSF200 STYLE# SSF160 STYLE# SSF100 ...

  • Therma-Tru Light Commercial Doors and Frames - page 5

    5 Therma-T ru ® Light Commercial/Multi-Family - Standard Hardware Preps. STEEL DEADBOL T PREP: ST AMPED 1 1/8" x 2 3/4" OPTIONAL DEADBOL T PREP FOR STEEL FRAMES. AV AILABLE WITH ADJUST A-FIT , ADJUST A-TRIM, HOLLOW MET AL, SECURA-FIT & VIST A III FRAMES. STEEL DEADBOL T PREP ST AMPED 1 1/18" x 2 3/4" OPTIONAL DEADBOL T PREP ...

  • Therma-Tru Light Commercial Doors and Frames - page 6

    6 Therma-T ru ® Light Commercial/Multi-Family - Hardware Locations NOMINAL 2-0 2-4 2-6 2-8 2-10 3-0 3-6 ACTUAL 23 11/16" 27 11/16" 29 11/16" 31 11/16" 33 11/16" 35 11/16" 41 11/16" NOMINAL 6-8 7-0 8-0 ACTUAL 78 5/8" 82 1/8" 93" MORTISE PREP 45 1/4" 45 1/4" 59 5/8" CYLINDRICAL PREP 44 ...

  • Therma-Tru Light Commercial Doors and Frames - page 7

    7 Therma-T ru ® Light Commercial/Multi-Family - Custom Elevations/Applications JOB NUMBER PROJECT LOCATION SHEET NUMBER OF ...

  • Therma-Tru Light Commercial Doors and Frames - page 8

    8 Therma-T ru ® Light Commercial/Multi-Family - Adjusta-Fit ® Frames - Single 2-0 x 6-8 2-4 x 6-8 2-6 x 6-8 2-8 x 6-8 SPRING LOADED 2-10 x 6-8 BALL BEARING 3-0 x 6-8 3-6 x 6-8 4 7/8" ANSI (STD) 2-0 x 7-0 2-4 x 7-0 2-6 x 7-0 2-8 x 7-0 2-10 x 7-0 3-0 x 7-0 3-6 x 7-0 83 1/4" 83 1/4" 83 1/4" 83 1/4" 83 1/4" 83 5/8" ...

  • Therma-Tru Light Commercial Doors and Frames - page 9

    9 Therma-T ru ® Light Commercial/Multi-Family - Adjusta-Fit ® Frames - Double FRAME DET AIL 4-0 = 48 17/32" 5-0 = 60 17/32" 5-4 = 64 17/32" 6-0 = 72 17/32" 4-0 = 49 1/2" 5-0 = 61 1/2" 5-4 = 65 1/2" 6-0 = 73 1/2" ADJUST A-FIT FRAME HINGE JAMB 4" x 4" HINGE ADJUST A-FIT FRAME INACTIVE HINGE JAMB 4&q ...

  • Therma-Tru Light Commercial Doors and Frames - page 10

    10 Therma-T ru ® Light Commercial/Multi-Family - Adjusta-T rim ® Frames - Single FRAME DET AIL EXISTING WALL ADJUST A-TRIM CLOSURE JAMB COMPRESSION WEA THERSTRIPPING COMPRESSION WEA THERSTRIPPING STEEL ENTRANCE DOOR 2-0 = 24" 2-4 = 28" 2-6 = 30" 2-8 = 32" 2-10 = 34" 3-0 = 36" 3-6 = 42" 2-10 = 35" 3-0 = 37&q ...

  • Therma-Tru Light Commercial Doors and Frames - page 11

    11 Therma-T ru ® Light Commercial/Multi-Family - Adjusta-T rim ® Frames - Double FRAME DET AIL 4-0 = 48 17/32" 5-0 = 60 17/32" 5-4 = 64 17/32" 6-0 = 72 17/32" 4-0 = 49" 5-0 = 61" 5-4 = 65" 6-0 = 73" WOOD SP ACER ADJUST A-TRIM FRAME HINGE JAMB 4" x 4" HINGE ADJUST A-TRIM FRAME INACTIVE HINGE JAMB 4 ...

  • Therma-Tru Light Commercial Doors and Frames - page 12

    12 Therma-T ru ® Light Commercial/Multi-Family - Secura-Fit ® Frames - Single 2-0 x 6-8 2-4 x 6-8 2-6 x 6-8 2-8 x 6-8 SPRING LOADED 2-10 x 6-8 BALL BEARING 3-0 x 6-8 2-0 x 7-0 T-STRIKE (STD) 2-4 x 7-0 T-STRIKE w/ DEADBOLT 2-6 x 7-0 2-8 x 7-0 2-10 x 7-0 3-0 x 7-0 JOB NUMBER PROJECT LOCATION NOMINAL ROUGH ROUGH FRAME OPENING OPENING OPENING WIDTH H ...

  • Therma-Tru Light Commercial Doors and Frames - page 13

    13 Therma-T ru ® Light Commercial/Multi-Family - Secura-Fit ® Frames - Double 4-0 x 6-8 5-0 x 6-8 5-4 x 6-8 6-0 x 6-8 SPRING LOADED 4-0 x 7-0 BALL BEARING 5-0 x 7-0 5-0 x 7-0 T-STRIKE (STD) 6-0 x 7-0 T-STRIKE w/ DEADBOLT JOB NUMBER PROJECT LOCATION NOMINAL ROUGH ROUGH FRAME OPENING OPENING OPENING WIDTH HEIGHT 47 3/4" - 48" 79 7/8" ...

メーカー Therma-Tru カテゴリー Door

Therma-Tru Light Commercial Doors and Framesのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Light Commercial Doors and Framesの取扱説明書
- Therma-Truの製品カード
- パンフレット
- またはTherma-Tru Light Commercial Doors and Framesの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Therma-Tru Light Commercial Doors and Framesの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Therma-Tru Light Commercial Doors and Framesの取り付け説明書、サービスマニュアル、簡易説明書、またはTherma-Tru Light Commercial Doors and Framesのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Therma-Tru Light Commercial Doors and Framesの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Therma-Tru Light Commercial Doors and Framesデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがTherma-Tru Light Commercial Doors and Framesを使用するのを助ける技術的文書のことです。説明書は通常、全てのTherma-Tru Light Commercial Doors and Framesユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Therma-Truの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Therma-Tru Light Commercial Doors and Framesの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははTherma-Tru Light Commercial Doors and Framesの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Therma-Tru Light Commercial Doors and Framesに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Therma-Tru Light Commercial Doors and Framesデバイスの基本機能を使うにあたってのヒント。 Therma-Tru Light Commercial Doors and Framesのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Therma-Tru Light Commercial Doors and Framesに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるTherma-Tru Light Commercial Doors and Framesのメーカー/サービスへの連絡先に関する情報。

Therma-Tru Light Commercial Doors and Framesについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもTherma-Tru Light Commercial Doors and Framesの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがTherma-Tru Light Commercial Doors and Framesで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)