Manuel d’utilisation Lochinvar SSS119

20 pages 0.88 mb
Télécharger

Aller à la page of 20

Summary
  • Lochinvar SSS119 - page 1

    Installa tion & Oper a tion Manual Models: SSS031, SSS041, SSS051, SSS081, & SSS119 T h i s ma n ua l m u s t o n ly b e us e d b y a qualified heating installer / serv ice technician. Read all instructions before installing. P erfor m steps in the order given. Failure to c omply could result in sev ere personal injur y , death, or substant ...

  • Lochinvar SSS119 - page 2

    Installation & Operation Manual 2 Hazar d definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Please r ead before pr oceeding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. General Infor mation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lochinvar SSS119 - page 3

    Installation & Operation Manual Please r ead bef ore pr oceeding Installer – R ead all instructions before installing. P erform steps in the order give n. Ha ve this indir ect water heat er serv iced/inspected by a qualified service technician, at least annually . Failure t o comply with the abov e could result in severe personal injury , dea ...

  • Lochinvar SSS119 - page 4

    Installation & Operation Manual 4 1 Gener al Infor mation The Lochin var SSS series indirect water heat er (FIG. 1-1) is designed to generate domestic hot water in conjunction with a hot water boiler using forc ed boiler water cir culation. This indirect water heat er consists of a 444 Stainless Steel tank in which a smooth 304 stainless steel ...

  • Lochinvar SSS119 - page 5

    Installation & Operation Manual 5 Failure t o properly support the tank could result in property damage or personal injur y .  W ARNING 2 Pre-installation 1. The installation must conform with the instructions in this manual and all applicable local, state, provincial, and national codes, la ws, regulations, and ordinances. Installations in ...

  • Lochinvar SSS119 - page 6

    Installation & Operation Manual 6 Boiler Side Piping Figures 3-1 thru 3-3 show typical boiler side piping for several common situations. Regardless of which system is used it is imperative that the flo w rates called for in T able 3A on page 6 are developed thr ough the coil. This requir es properly sized piping and a pr operly sized pump . The ...

  • Lochinvar SSS119 - page 7

    Installation & Operation Manual 7 SOLUTION BOILER SQUIRE ANTI-SCALD MIXING VALVE COLD WA TER IN TEMPERATURE / PRESSURE GAUGE AIR SEPARATOR ZONE #1 ZONE #2 ZONE #3 ZONE #4 BALL VALVE (TYPICAL) UNION (TYPICAL) PRESSURE RELIEF VALVE DRAIN POINT (TYPICAL) MAK E U P W A TER HOT WA TE R OUT BOILER CIRCULATOR BACKFLOW PREVENTER PRESSURE REDUCING VALVE ...

  • Lochinvar SSS119 - page 8

    Installation & Operation Manual 8 3 Piping SOLUTION BOILER SQUIRE ANTI-SCALD MIXING VALVE COLD WA TER IN TEMPERATURE / PRESSURE GAUGE AIR SEPARATOR ZONE #1 ZONE #2 ZONE #3 ZONE #4 BALL VALVE (TYPICAL) UNION (TYPICAL) PRESSURE RELIEF VALVE DRAIN POINT (TYPICAL) MAK E U P W AT ER HOT WA TE R OUT BOILER CIRCULATOR BACKFLOW PREVENTER PRESSURE REDUC ...

  • Lochinvar SSS119 - page 9

    Installation & Operation Manual 9 3 Piping (continued) Figure 3-4 Multiple T ank Connections BOILER DOMESTIC HOT W ATER CIRCULATO R BACKFLOW PREVENTER PRESSURE REDUCING VALVE PRESSURE GAUGE ANTI-SCALD MIXING VALVE COLD WA TER IN TEMPERATURE / PRESSURE GAUGE AIR SEPARATOR EXPANSION TANK BALL VALVE (TYPICAL) UNION (TYPICAL) PRESSURE RELIEF VALVE ...

  • Lochinvar SSS119 - page 10

    Installation & Operation Manual 10 3 Piping Domestic Side Piping Basic Domestic Piping Figure 3-5 on page 12 sho ws ty pical domestic water piping for a tank. All c omponents ex cept the control are pr ovided by the installer . The function of the components shown are as follows: a. Shut-off valves (recommended) - U se to isolate the tank for s ...

  • Lochinvar SSS119 - page 11

    Installation & Operation Manual 11 3 Piping (continued) W hen no fixtures are dra wing water , the br onze cir culator mov es hot water from the tank t o the end of the branch just below the last fixtur e, then back to the inlet of the tank v ia the return pipe. W hen a fixture is opened, hot water is alr eady out in the branch very close to th ...

  • Lochinvar SSS119 - page 12

    Installation & Operation Manual 12 3 Piping Figure 3-5 Recommended Domestic Water Piping ...

  • Lochinvar SSS119 - page 13

    Installation & Operation Manual 13 4 W iring Indirect Water Hea ter Sensor Setup (Knight Boiler) Label all wires prior to disconnection when serv icing controls. W ir ing errors can cause improper and dangerous operation.  CAUTION 1. Install the sensor inside the tank as depicted in FIG. 4-1. 2. Connect the wire leads to the DHW T ank Sensor ...

  • Lochinvar SSS119 - page 14

    Installation & Operation Manual 14 4 W iring IDW Contr olled Using Aquastat and Zone Circulator / V alv e 1. Install A quastat to tank. A quastat contr ol (TST1085) can be ordered from y our local Lochin var dist ributor . 2. Connect A quastat to the zone c ontroller for the I ndirect W ater Heat er Zone. 3. Adjust Aquastat to the desir ed temp ...

  • Lochinvar SSS119 - page 15

    Installation & Operation Manual 15 5 Star t-up and Check-out 1. Make sure the syst em is free of leaks and that air is purged from the system. CAUTION Fix any leaks found befor e proc eeding further . Leakage from the boiler piping can result in sever e damage to the boiler . 2. Many soldering flux es contain Zinc Chloride which can cause sever ...

  • Lochinvar SSS119 - page 16

    LIM IT ED LIFETIME INDIRECT W A TER HEA TER W ARRANTY WHA T DOES THIS LIMITED W ARRANTY COVER? This limited lifetime warranty covers the stainless steel tank, stainless steel heat exchanger coil and component parts for leakage or other malfunction caused by defects in materials and/or workmanship. It extends to the first buyer and to any subsequent ...

  • Lochinvar SSS119 - page 17

    LIM ITE D LIFETIME INDIRECT W A TER HEA TER W ARRANTY (CONTINUED) ©–12/06—Printed in U.S.A. WHA T WILL WE DO T O CORRECT PROBLEM? If a defect occurs within the warranty period, we will: 1. Provide a comparable replacement water heater of our manufacture, (or at our option repair) any unit which develops a leak in the stainless steel tank or he ...

  • Lochinvar SSS119 - page 18

    18 Notes ...

  • Lochinvar SSS119 - page 19

    19 Notes ...

  • Lochinvar SSS119 - page 20

    Revision Notes: Revision B (SSS-I&O-Rev B) reflects edits and additions made to the piping diagrams. Revision C (SSS-I&O-Rev C) reflects edits made to the piping diagrams, the DHW T ank Sensor (AUX) and the addition of the warranty . Revision D (ECO #C02870) reflects the addition of the scald chart on page 3. SSS-I&O Rev D 1/09 - Printe ...

Fabricant Lochinvar Catégorie Water Heater

Les documents que nous recevons du fabricant de l'appareilLochinvar SSS119 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lochinvar
- manuels d’utilisations SSS119
- fiches produit Lochinvar
- dépliants
- ou étiquettes-énergie Lochinvar SSS119
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lochinvar SSS119.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lochinvar SSS119, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lochinvar SSS119. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lochinvar SSS119.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Lochinvar SSS119, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lochinvar SSS119 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lochinvar SSS119.

Le manuel d’utilisation complet Lochinvar, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lochinvar SSS119 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lochinvar SSS119, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLochinvar SSS119 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lochinvar SSS119 - qui devraient nous aider dans les premières étapes lors de l'utilisation Lochinvar SSS119
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lochinvar SSS119
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lochinvar SSS119 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lochinvar SSS119?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lochinvar SSS119, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lochinvar SSS119 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)