Manuale per l’uso Lochinvar SSS119

20 pagine 0.88 mb
Scarica

Vai alla pagina of 20

Summary
  • Lochinvar SSS119 - page 1

    Installa tion & Oper a tion Manual Models: SSS031, SSS041, SSS051, SSS081, & SSS119 T h i s ma n ua l m u s t o n ly b e us e d b y a qualified heating installer / serv ice technician. Read all instructions before installing. P erfor m steps in the order given. Failure to c omply could result in sev ere personal injur y , death, or substant ...

  • Lochinvar SSS119 - page 2

    Installation & Operation Manual 2 Hazar d definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Please r ead before pr oceeding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. General Infor mation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Lochinvar SSS119 - page 3

    Installation & Operation Manual Please r ead bef ore pr oceeding Installer – R ead all instructions before installing. P erform steps in the order give n. Ha ve this indir ect water heat er serv iced/inspected by a qualified service technician, at least annually . Failure t o comply with the abov e could result in severe personal injury , dea ...

  • Lochinvar SSS119 - page 4

    Installation & Operation Manual 4 1 Gener al Infor mation The Lochin var SSS series indirect water heat er (FIG. 1-1) is designed to generate domestic hot water in conjunction with a hot water boiler using forc ed boiler water cir culation. This indirect water heat er consists of a 444 Stainless Steel tank in which a smooth 304 stainless steel ...

  • Lochinvar SSS119 - page 5

    Installation & Operation Manual 5 Failure t o properly support the tank could result in property damage or personal injur y .  W ARNING 2 Pre-installation 1. The installation must conform with the instructions in this manual and all applicable local, state, provincial, and national codes, la ws, regulations, and ordinances. Installations in ...

  • Lochinvar SSS119 - page 6

    Installation & Operation Manual 6 Boiler Side Piping Figures 3-1 thru 3-3 show typical boiler side piping for several common situations. Regardless of which system is used it is imperative that the flo w rates called for in T able 3A on page 6 are developed thr ough the coil. This requir es properly sized piping and a pr operly sized pump . The ...

  • Lochinvar SSS119 - page 7

    Installation & Operation Manual 7 SOLUTION BOILER SQUIRE ANTI-SCALD MIXING VALVE COLD WA TER IN TEMPERATURE / PRESSURE GAUGE AIR SEPARATOR ZONE #1 ZONE #2 ZONE #3 ZONE #4 BALL VALVE (TYPICAL) UNION (TYPICAL) PRESSURE RELIEF VALVE DRAIN POINT (TYPICAL) MAK E U P W A TER HOT WA TE R OUT BOILER CIRCULATOR BACKFLOW PREVENTER PRESSURE REDUCING VALVE ...

  • Lochinvar SSS119 - page 8

    Installation & Operation Manual 8 3 Piping SOLUTION BOILER SQUIRE ANTI-SCALD MIXING VALVE COLD WA TER IN TEMPERATURE / PRESSURE GAUGE AIR SEPARATOR ZONE #1 ZONE #2 ZONE #3 ZONE #4 BALL VALVE (TYPICAL) UNION (TYPICAL) PRESSURE RELIEF VALVE DRAIN POINT (TYPICAL) MAK E U P W AT ER HOT WA TE R OUT BOILER CIRCULATOR BACKFLOW PREVENTER PRESSURE REDUC ...

  • Lochinvar SSS119 - page 9

    Installation & Operation Manual 9 3 Piping (continued) Figure 3-4 Multiple T ank Connections BOILER DOMESTIC HOT W ATER CIRCULATO R BACKFLOW PREVENTER PRESSURE REDUCING VALVE PRESSURE GAUGE ANTI-SCALD MIXING VALVE COLD WA TER IN TEMPERATURE / PRESSURE GAUGE AIR SEPARATOR EXPANSION TANK BALL VALVE (TYPICAL) UNION (TYPICAL) PRESSURE RELIEF VALVE ...

  • Lochinvar SSS119 - page 10

    Installation & Operation Manual 10 3 Piping Domestic Side Piping Basic Domestic Piping Figure 3-5 on page 12 sho ws ty pical domestic water piping for a tank. All c omponents ex cept the control are pr ovided by the installer . The function of the components shown are as follows: a. Shut-off valves (recommended) - U se to isolate the tank for s ...

  • Lochinvar SSS119 - page 11

    Installation & Operation Manual 11 3 Piping (continued) W hen no fixtures are dra wing water , the br onze cir culator mov es hot water from the tank t o the end of the branch just below the last fixtur e, then back to the inlet of the tank v ia the return pipe. W hen a fixture is opened, hot water is alr eady out in the branch very close to th ...

  • Lochinvar SSS119 - page 12

    Installation & Operation Manual 12 3 Piping Figure 3-5 Recommended Domestic Water Piping ...

  • Lochinvar SSS119 - page 13

    Installation & Operation Manual 13 4 W iring Indirect Water Hea ter Sensor Setup (Knight Boiler) Label all wires prior to disconnection when serv icing controls. W ir ing errors can cause improper and dangerous operation.  CAUTION 1. Install the sensor inside the tank as depicted in FIG. 4-1. 2. Connect the wire leads to the DHW T ank Sensor ...

  • Lochinvar SSS119 - page 14

    Installation & Operation Manual 14 4 W iring IDW Contr olled Using Aquastat and Zone Circulator / V alv e 1. Install A quastat to tank. A quastat contr ol (TST1085) can be ordered from y our local Lochin var dist ributor . 2. Connect A quastat to the zone c ontroller for the I ndirect W ater Heat er Zone. 3. Adjust Aquastat to the desir ed temp ...

  • Lochinvar SSS119 - page 15

    Installation & Operation Manual 15 5 Star t-up and Check-out 1. Make sure the syst em is free of leaks and that air is purged from the system. CAUTION Fix any leaks found befor e proc eeding further . Leakage from the boiler piping can result in sever e damage to the boiler . 2. Many soldering flux es contain Zinc Chloride which can cause sever ...

  • Lochinvar SSS119 - page 16

    LIM IT ED LIFETIME INDIRECT W A TER HEA TER W ARRANTY WHA T DOES THIS LIMITED W ARRANTY COVER? This limited lifetime warranty covers the stainless steel tank, stainless steel heat exchanger coil and component parts for leakage or other malfunction caused by defects in materials and/or workmanship. It extends to the first buyer and to any subsequent ...

  • Lochinvar SSS119 - page 17

    LIM ITE D LIFETIME INDIRECT W A TER HEA TER W ARRANTY (CONTINUED) ©–12/06—Printed in U.S.A. WHA T WILL WE DO T O CORRECT PROBLEM? If a defect occurs within the warranty period, we will: 1. Provide a comparable replacement water heater of our manufacture, (or at our option repair) any unit which develops a leak in the stainless steel tank or he ...

  • Lochinvar SSS119 - page 18

    18 Notes ...

  • Lochinvar SSS119 - page 19

    19 Notes ...

  • Lochinvar SSS119 - page 20

    Revision Notes: Revision B (SSS-I&O-Rev B) reflects edits and additions made to the piping diagrams. Revision C (SSS-I&O-Rev C) reflects edits made to the piping diagrams, the DHW T ank Sensor (AUX) and the addition of the warranty . Revision D (ECO #C02870) reflects the addition of the scald chart on page 3. SSS-I&O Rev D 1/09 - Printe ...

Fabbricante Lochinvar Categoria Water Heater

I documenti che otteniamo dal fabbricante del dispositivoLochinvar SSS119 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Lochinvar
- manuali per l’uso SSS119
- schede prodotto Lochinvar
- opuscoli
- o etichette energetiche Lochinvar SSS119
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Lochinvar SSS119.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Lochinvar SSS119, manuali di manutenzione, brevi manuali o manuali utente Lochinvar SSS119. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Lochinvar SSS119.

Manuali per l’uso simili

Manuale completo del dispositivo Lochinvar SSS119, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Lochinvar SSS119 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Lochinvar SSS119.

Il manuale per l’uso completo Lochinvar, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Lochinvar SSS119 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Lochinvar SSS119, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Lochinvar SSS119 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Lochinvar SSS119 - che ci dovrebbe aiutare nei primi passi durante l'uso Lochinvar SSS119
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Lochinvar SSS119
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Lochinvar SSS119 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Lochinvar SSS119?

Utilizza il modulo sottostante

Se non hai risolto il problema con Lochinvar SSS119 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Lochinvar SSS119 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)