Manuel d’utilisation Health O Meter 2000KL

29 pages 0.68 mb
Télécharger

Aller à la page of 29

Summary
  • Health O Meter 2000KL - page 1

    PRO PLUS ® STRETCHER SCALE MODEL 2000KL OPERATION MANUAL AA0339-0 ...

  • Health O Meter 2000KL - page 2

    1 PRO PLUS ® STRETCHER SCALE MODEL 2000KL Thank you for your purchase of this product. Please read this manual carefully and keep it handy for ready reference. TABLE OF CONTENTS CAUTION AND WARNING .................................................................................................... 2 SPECIFICATIONS ................................. ...

  • Health O Meter 2000KL - page 3

    2 CAUTION AND WARNING To prevent injury and damage to your scale, pleas e follow these instructions very carefully. • To ensure proper operation of the ProPlus® Stretcher Scale, this operation manual should be reviewed carefully before operation. Keep this manual available for future reference, and also for use in the orientation of new personne ...

  • Health O Meter 2000KL - page 4

    3 SPECIFICATIONS GENERAL Health o meter’s ProPlus ® Stretcher Scale Model 2000KL uses highly sophisticated microprocessor technology. This scale is designed to provide accurate, reliable and repeatable weight measurements and features that make the weighing process simple, fast and convenient. The scale is set up to use motion-sensing weighing t ...

  • Health O Meter 2000KL - page 5

    4 ASSEMBLY INSTRUCTIONS Before Assembly The Model 2000KL ProPlus® Stretcher Scale is shipped disassembled in two (2) separate cartons. Carefully inspect all cartons for shipping damage before unpacking. If damage is found, contact your shipper or Healthometer Professional immediately. Claims must be filed with the shipper as soon as possible after ...

  • Health O Meter 2000KL - page 6

    5 ASSEMBLY INSTRUCTIONS Assembling the Patient Lifter 1. Place the Stretcher Storage Tray on the Lifter Base, as shown below, before attaching the Lifter Mast. Figure 2 2. Remove black plastic protective caps from Lifter Mast. Insert the bottom of the Lifter Mast and Hydraulic Pump assembly into the mast sleeve (through the Stretcher Tray Holder) o ...

  • Health O Meter 2000KL - page 7

    6 ASSEMBLY INSTRUCTIONS Attaching the Display and Scale to the Patient Lifter Figure 2 Figure 3 PHILLIPS PAN HEAD SCREW NC8-32x5/16 ...

  • Health O Meter 2000KL - page 8

    7 ASSEMBLY INSTRUCTIONS 4. Connect the Lifter Boom and the Display Support to the Lifter Mast using the NC ⅜ - 20x2 ½” hex screw and tighten the self lock nut on its other side. Note : This screw is the axis of the Lifter Boom, so it is imperative that the three parts – Lifter Boom, Lifter Mast and Display Support – be assembled in the pro ...

  • Health O Meter 2000KL - page 9

    8 ASSEMBLY INSTRUCTIONS Figure 4 10. Position the Display Assembly close to the Display Support. Connect the load cell cable connector to the load cell port on the rear of the Display Assembly and insert and secure the cable into the center channel in the display. Note : Do not attach the power cord at this point. 11. Slide the display assembly ont ...

  • Health O Meter 2000KL - page 10

    9 ASSEMBLY INSTRUCTIONS Figure 5 15. Hang the Load Cell Assembly on the two hooks at the end of the Lifter Boom, using the loops on top of the Load Cell Assembly. 16. Connect the end of the Load Cell Cable coming out of the center of the Load Cell Assembly to its port in the Lifter Boom. 17 Use the two washers and shoulder screws to connect the two ...

  • Health O Meter 2000KL - page 11

    10 SET UP Preparing the Scale for Use 1. Remove protective plastic film from keypad and display. 2. Place batteries in the battery holder (see “Replacing Batteries”). 3. Plug the scale’s AC adapter into the power source. 4. Press the ON/OFF button to turn the scale on. The display will show “Health o Meter Pro-Plus” and then ”000 Lb 00 ...

  • Health O Meter 2000KL - page 12

    11 OPERATION INSTRUCTIONS Preweighing the Stretcher 1. Make sure the scale is free of load (nothing is hanging from it), including the stretcher. 2. Press the ON/OFF button to turn the scale on. 3. Wait until ”000 Lb 00 oz ” and “ZERO” on the left side of the display will appear. The scale will remember the last amount that was tared, so if ...

  • Health O Meter 2000KL - page 13

    12 OPERATION INSTRUCTIONS 4. Release the hanging loops from the lifter. Note : The scale is programmed to save the last setting chosen as well as the weight of the stretcher as tare weight. This enables weighing a number of patients without having to re- set the scale. If a weight was added or reduced from the stretcher scale it is required to rese ...

  • Health O Meter 2000KL - page 14

    13 OPERATION INSTRUCTIONS Figure 7. Keypad ITEM DESCRIPTION FUNCTION POWER Turns scale ON and OFF. ZERO Zeros the scale prior to weighing. HOLD/RELEASE Holds the value of the weighed object on the display until the button is pressed again to clear the value. Also used to scroll down in the menu. REWEIGH Allows repeated weighing of the patient witho ...

  • Health O Meter 2000KL - page 15

    14 OPERATION INSTRUCTIONS MENU In the menu screen the user can set preferences and/or instruct the scale how to handle stored data. The menu can be navigated using the up and down keys ( cd ) or by entering the associated menu position number with the keypad. The menu has a “roll-over” way of working: when the user scrolls to the bottom of the ...

  • Health O Meter 2000KL - page 16

    15 OPERATION INSTRUCTIONS 02 TARE WEIGHT NOTE : Due to the scale’s sensitivity, we recommend using the REWEIGH function prior to setting the TARE weight, in order to eliminate any operator interference with the item to be tared out. There are two ways to manually enter a tare weight (such as the weight of a stretcher , shoes, etc): press MENU (1) ...

  • Health O Meter 2000KL - page 17

    16 OPERATION INSTRUCTIONS 3. The scale will prompt you to enter the patient’s height. Use the keypad to enter the height in 1/4" (1=1/4, 2=1/2, 3=3/4) or 1 cm increments (use inches for weight in lb, cm for kg). Press ENTER. 4. Display will read the patient’s BMI. The scale offers you two options to manage your in formation: to transfer/do ...

  • Health O Meter 2000KL - page 18

    17 OPERATION INSTRUCTIONS 04 Transfer now All the values stored in memory are transferred to the PC and the scale memory is cleared of all values. If the transfer was unsuccessful, the values are kept in memory until successfully transferred or cleared. 05 Clear memory All the values stored in memory will be cleared. 04 SCALE SETTINGS 01 Auto Hold ...

  • Health O Meter 2000KL - page 19

    18 OPERATION INSTRUCTIONS 03 Auto Off Time The user can determine how long the scale will operate before turning off automatically due to inactivity. Default time is 10 minutes. If the value is set to zero, the auto off function is disabled. 04 Tone Volume There is an option to adjust the beeping tone of the scale. This tone should sound when the s ...

  • Health O Meter 2000KL - page 20

    19 OPERATION INSTRUCTIONS 06 Display Backlight The user can set the brightness of the backlight. 07 Display Contrast The user can set the brightness of the LCD. 08 Live Weight By selecting “Yes” the user can set the Live Weight mode to deactivate the motion-sensing mode. In the Live Weight mode the weight displayed will fluctuate with the patie ...

  • Health O Meter 2000KL - page 21

    20 OPERATION INSTRUCTIONS Set the date using the up and down keys cd and enter the values on the keypad. 02 About This screen displays the software version of the scale. 06 SYSTEM TEST 01 Battery Test The scale will display the estimated amount of battery life remaining until the batteries will have to be replaced. NOTE : In order to complete the b ...

  • Health O Meter 2000KL - page 22

    21 OPERATION INSTRUCTIONS 03 UI Test The scale has a diagnostic routine where it tests the User Interface (UI) hardware functionality (LCD, keypad). In order to do this the user has to press all the keys according to the messages displayed on the screen. If the requested command was not received or wrong button was pressed, the following message wi ...

  • Health O Meter 2000KL - page 23

    22 OPERATION INSTRUCTIONS 02 Disp Height & ID When the user selects to display the height and ID of the user, it will be displayed at the bottom of the screen. We recommend the use of this function to ensure that the patient’s correct ID and height have been entered. 03 Prompt For Height When this option is activated, the user will be asked t ...

  • Health O Meter 2000KL - page 24

    23 MAINTENANCE GENERAL This section provides instructions for maintenance, cleaning, troubleshooting and operator replaceable parts for the ProPlus ® Stretcher Scale Model 2000KL. Maintenance operations other than those described in this section should be performed by qualified service personnel. MAINTENANCE Before first use and after periods of n ...

  • Health O Meter 2000KL - page 25

    24 TROUBLESHOOTING Refer to the following instructions to check and correct any failure before contacting service personnel. SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Scale does not turn on 1. Dead Battery 2. Faulty electrical outlet 3. Bad power supply 1. Replace batteries 2. Use a different outlet 3. Replace adapter Questionable weight or the scal ...

  • Health O Meter 2000KL - page 26

    25 CALIBRATION PATH The calibration is performed in Kg or Lb, according to the units of measure used upon entering into the calibration path. Operator Action Display 1. Press ON/OFF button and immediately press and hold HOLD/RELEASE button for 3-4 seconds Calibration Process 2. Press ENTER Enter load weight 400.0 3. Using cd keys and/or the keypad, ...

  • Health O Meter 2000KL - page 27

    26 EXPLODED VIEW OF SCALE (continue) ...

  • Health O Meter 2000KL - page 28

    27 PARTS LIST Key No. Part No . Description Qty. 1 1109403-0 DISPLAY ASSEMBLY 1 2 2268101-0 TILT MECH. ASSEMBLY 1 3 3848401-0 PLASTIC WASHER 2 4 401369 PLASTIC OVAL BAR COVER 3 5 HEX. HEAD SCREW NC 3/8-16*2 1/2 1 6 HEX. HEAD SCREW NC 3/8-16*1 3/4 1 7 2268001-0 LIFTER BOOM ASSEMBLY 1 8 2034701-0 MAIN BOARD TO CON. DIG CABLE 1 9 3809801-0 BEAM ASSEMB ...

  • Health O Meter 2000KL - page 29

    28 WARRANTY LIMITED WARRANTY What does the Warranty Cover? Pelstar LLC scales are warranted from date of purchase against defects of materials or in workmanship for a period of three (3) years. If product fails to function properly, return the product, freight prepaid and properly packed to Pelstar. See “To Get Warranty Service” below for instr ...

Fabricant Health O Meter Catégorie Scale

Les documents que nous recevons du fabricant de l'appareilHealth O Meter 2000KL peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Health O Meter
- manuels d’utilisations 2000KL
- fiches produit Health O Meter
- dépliants
- ou étiquettes-énergie Health O Meter 2000KL
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Health O Meter 2000KL.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Health O Meter 2000KL, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Health O Meter 2000KL. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Health O Meter 2000KL.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Health O Meter 2000KL, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Health O Meter 2000KL par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Health O Meter 2000KL.

Le manuel d’utilisation complet Health O Meter, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Health O Meter 2000KL - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Health O Meter 2000KL, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHealth O Meter 2000KL qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Health O Meter 2000KL - qui devraient nous aider dans les premières étapes lors de l'utilisation Health O Meter 2000KL
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Health O Meter 2000KL
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Health O Meter 2000KL dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Health O Meter 2000KL?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Health O Meter 2000KL, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Health O Meter 2000KL il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)