Manual de instrucciones Health O Meter 2000KL

29 de páginas 0.68 mb
Descargar

Pasar a la página of 29

Summary
  • Health O Meter 2000KL - page 1

    PRO PLUS ® STRETCHER SCALE MODEL 2000KL OPERATION MANUAL AA0339-0 ...

  • Health O Meter 2000KL - page 2

    1 PRO PLUS ® STRETCHER SCALE MODEL 2000KL Thank you for your purchase of this product. Please read this manual carefully and keep it handy for ready reference. TABLE OF CONTENTS CAUTION AND WARNING .................................................................................................... 2 SPECIFICATIONS ................................. ...

  • Health O Meter 2000KL - page 3

    2 CAUTION AND WARNING To prevent injury and damage to your scale, pleas e follow these instructions very carefully. • To ensure proper operation of the ProPlus® Stretcher Scale, this operation manual should be reviewed carefully before operation. Keep this manual available for future reference, and also for use in the orientation of new personne ...

  • Health O Meter 2000KL - page 4

    3 SPECIFICATIONS GENERAL Health o meter’s ProPlus ® Stretcher Scale Model 2000KL uses highly sophisticated microprocessor technology. This scale is designed to provide accurate, reliable and repeatable weight measurements and features that make the weighing process simple, fast and convenient. The scale is set up to use motion-sensing weighing t ...

  • Health O Meter 2000KL - page 5

    4 ASSEMBLY INSTRUCTIONS Before Assembly The Model 2000KL ProPlus® Stretcher Scale is shipped disassembled in two (2) separate cartons. Carefully inspect all cartons for shipping damage before unpacking. If damage is found, contact your shipper or Healthometer Professional immediately. Claims must be filed with the shipper as soon as possible after ...

  • Health O Meter 2000KL - page 6

    5 ASSEMBLY INSTRUCTIONS Assembling the Patient Lifter 1. Place the Stretcher Storage Tray on the Lifter Base, as shown below, before attaching the Lifter Mast. Figure 2 2. Remove black plastic protective caps from Lifter Mast. Insert the bottom of the Lifter Mast and Hydraulic Pump assembly into the mast sleeve (through the Stretcher Tray Holder) o ...

  • Health O Meter 2000KL - page 7

    6 ASSEMBLY INSTRUCTIONS Attaching the Display and Scale to the Patient Lifter Figure 2 Figure 3 PHILLIPS PAN HEAD SCREW NC8-32x5/16 ...

  • Health O Meter 2000KL - page 8

    7 ASSEMBLY INSTRUCTIONS 4. Connect the Lifter Boom and the Display Support to the Lifter Mast using the NC ⅜ - 20x2 ½” hex screw and tighten the self lock nut on its other side. Note : This screw is the axis of the Lifter Boom, so it is imperative that the three parts – Lifter Boom, Lifter Mast and Display Support – be assembled in the pro ...

  • Health O Meter 2000KL - page 9

    8 ASSEMBLY INSTRUCTIONS Figure 4 10. Position the Display Assembly close to the Display Support. Connect the load cell cable connector to the load cell port on the rear of the Display Assembly and insert and secure the cable into the center channel in the display. Note : Do not attach the power cord at this point. 11. Slide the display assembly ont ...

  • Health O Meter 2000KL - page 10

    9 ASSEMBLY INSTRUCTIONS Figure 5 15. Hang the Load Cell Assembly on the two hooks at the end of the Lifter Boom, using the loops on top of the Load Cell Assembly. 16. Connect the end of the Load Cell Cable coming out of the center of the Load Cell Assembly to its port in the Lifter Boom. 17 Use the two washers and shoulder screws to connect the two ...

  • Health O Meter 2000KL - page 11

    10 SET UP Preparing the Scale for Use 1. Remove protective plastic film from keypad and display. 2. Place batteries in the battery holder (see “Replacing Batteries”). 3. Plug the scale’s AC adapter into the power source. 4. Press the ON/OFF button to turn the scale on. The display will show “Health o Meter Pro-Plus” and then ”000 Lb 00 ...

  • Health O Meter 2000KL - page 12

    11 OPERATION INSTRUCTIONS Preweighing the Stretcher 1. Make sure the scale is free of load (nothing is hanging from it), including the stretcher. 2. Press the ON/OFF button to turn the scale on. 3. Wait until ”000 Lb 00 oz ” and “ZERO” on the left side of the display will appear. The scale will remember the last amount that was tared, so if ...

  • Health O Meter 2000KL - page 13

    12 OPERATION INSTRUCTIONS 4. Release the hanging loops from the lifter. Note : The scale is programmed to save the last setting chosen as well as the weight of the stretcher as tare weight. This enables weighing a number of patients without having to re- set the scale. If a weight was added or reduced from the stretcher scale it is required to rese ...

  • Health O Meter 2000KL - page 14

    13 OPERATION INSTRUCTIONS Figure 7. Keypad ITEM DESCRIPTION FUNCTION POWER Turns scale ON and OFF. ZERO Zeros the scale prior to weighing. HOLD/RELEASE Holds the value of the weighed object on the display until the button is pressed again to clear the value. Also used to scroll down in the menu. REWEIGH Allows repeated weighing of the patient witho ...

  • Health O Meter 2000KL - page 15

    14 OPERATION INSTRUCTIONS MENU In the menu screen the user can set preferences and/or instruct the scale how to handle stored data. The menu can be navigated using the up and down keys ( cd ) or by entering the associated menu position number with the keypad. The menu has a “roll-over” way of working: when the user scrolls to the bottom of the ...

  • Health O Meter 2000KL - page 16

    15 OPERATION INSTRUCTIONS 02 TARE WEIGHT NOTE : Due to the scale’s sensitivity, we recommend using the REWEIGH function prior to setting the TARE weight, in order to eliminate any operator interference with the item to be tared out. There are two ways to manually enter a tare weight (such as the weight of a stretcher , shoes, etc): press MENU (1) ...

  • Health O Meter 2000KL - page 17

    16 OPERATION INSTRUCTIONS 3. The scale will prompt you to enter the patient’s height. Use the keypad to enter the height in 1/4" (1=1/4, 2=1/2, 3=3/4) or 1 cm increments (use inches for weight in lb, cm for kg). Press ENTER. 4. Display will read the patient’s BMI. The scale offers you two options to manage your in formation: to transfer/do ...

  • Health O Meter 2000KL - page 18

    17 OPERATION INSTRUCTIONS 04 Transfer now All the values stored in memory are transferred to the PC and the scale memory is cleared of all values. If the transfer was unsuccessful, the values are kept in memory until successfully transferred or cleared. 05 Clear memory All the values stored in memory will be cleared. 04 SCALE SETTINGS 01 Auto Hold ...

  • Health O Meter 2000KL - page 19

    18 OPERATION INSTRUCTIONS 03 Auto Off Time The user can determine how long the scale will operate before turning off automatically due to inactivity. Default time is 10 minutes. If the value is set to zero, the auto off function is disabled. 04 Tone Volume There is an option to adjust the beeping tone of the scale. This tone should sound when the s ...

  • Health O Meter 2000KL - page 20

    19 OPERATION INSTRUCTIONS 06 Display Backlight The user can set the brightness of the backlight. 07 Display Contrast The user can set the brightness of the LCD. 08 Live Weight By selecting “Yes” the user can set the Live Weight mode to deactivate the motion-sensing mode. In the Live Weight mode the weight displayed will fluctuate with the patie ...

  • Health O Meter 2000KL - page 21

    20 OPERATION INSTRUCTIONS Set the date using the up and down keys cd and enter the values on the keypad. 02 About This screen displays the software version of the scale. 06 SYSTEM TEST 01 Battery Test The scale will display the estimated amount of battery life remaining until the batteries will have to be replaced. NOTE : In order to complete the b ...

  • Health O Meter 2000KL - page 22

    21 OPERATION INSTRUCTIONS 03 UI Test The scale has a diagnostic routine where it tests the User Interface (UI) hardware functionality (LCD, keypad). In order to do this the user has to press all the keys according to the messages displayed on the screen. If the requested command was not received or wrong button was pressed, the following message wi ...

  • Health O Meter 2000KL - page 23

    22 OPERATION INSTRUCTIONS 02 Disp Height & ID When the user selects to display the height and ID of the user, it will be displayed at the bottom of the screen. We recommend the use of this function to ensure that the patient’s correct ID and height have been entered. 03 Prompt For Height When this option is activated, the user will be asked t ...

  • Health O Meter 2000KL - page 24

    23 MAINTENANCE GENERAL This section provides instructions for maintenance, cleaning, troubleshooting and operator replaceable parts for the ProPlus ® Stretcher Scale Model 2000KL. Maintenance operations other than those described in this section should be performed by qualified service personnel. MAINTENANCE Before first use and after periods of n ...

  • Health O Meter 2000KL - page 25

    24 TROUBLESHOOTING Refer to the following instructions to check and correct any failure before contacting service personnel. SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Scale does not turn on 1. Dead Battery 2. Faulty electrical outlet 3. Bad power supply 1. Replace batteries 2. Use a different outlet 3. Replace adapter Questionable weight or the scal ...

  • Health O Meter 2000KL - page 26

    25 CALIBRATION PATH The calibration is performed in Kg or Lb, according to the units of measure used upon entering into the calibration path. Operator Action Display 1. Press ON/OFF button and immediately press and hold HOLD/RELEASE button for 3-4 seconds Calibration Process 2. Press ENTER Enter load weight 400.0 3. Using cd keys and/or the keypad, ...

  • Health O Meter 2000KL - page 27

    26 EXPLODED VIEW OF SCALE (continue) ...

  • Health O Meter 2000KL - page 28

    27 PARTS LIST Key No. Part No . Description Qty. 1 1109403-0 DISPLAY ASSEMBLY 1 2 2268101-0 TILT MECH. ASSEMBLY 1 3 3848401-0 PLASTIC WASHER 2 4 401369 PLASTIC OVAL BAR COVER 3 5 HEX. HEAD SCREW NC 3/8-16*2 1/2 1 6 HEX. HEAD SCREW NC 3/8-16*1 3/4 1 7 2268001-0 LIFTER BOOM ASSEMBLY 1 8 2034701-0 MAIN BOARD TO CON. DIG CABLE 1 9 3809801-0 BEAM ASSEMB ...

  • Health O Meter 2000KL - page 29

    28 WARRANTY LIMITED WARRANTY What does the Warranty Cover? Pelstar LLC scales are warranted from date of purchase against defects of materials or in workmanship for a period of three (3) years. If product fails to function properly, return the product, freight prepaid and properly packed to Pelstar. See “To Get Warranty Service” below for instr ...

Fabricante Health O Meter Categoría Scale

Los documentos del dispositivo Health O Meter 2000KL que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Health O Meter
- manuales de instrucciones 2000KL
- hojas de producto Health O Meter
- folletos informativos
- o etiquetas energéticas Health O Meter 2000KL
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Health O Meter 2000KL.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Health O Meter 2000KL, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Health O Meter 2000KL. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Health O Meter 2000KL.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Health O Meter 2000KL, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Health O Meter 2000KL. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Health O Meter 2000KL.

El manual de instrucciones completo de Health O Meter debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Health O Meter 2000KL - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Health O Meter 2000KL, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Health O Meter 2000KL que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Health O Meter 2000KL - que deben facilitarnos los primeros pasos durante el uso de Health O Meter 2000KL
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Health O Meter 2000KL
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Health O Meter 2000KL en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Health O Meter 2000KL?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Health O Meter 2000KL, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Health O Meter 2000KL probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)