    1 Introduction The 2-Port RS-232/422/485 Serial over IP Ethernet Device Server is designed to operate serial ports over 10/100 Mbps Ethernet networks, transmitting via TCP/IP protocol. Features and Benefits • ARM Cortex-M3 32-bit high performance CPU • Auto reset on Idle detection • Easy to use Web Server Management • 115.2Kbps data through ...

  • Siig ID-DS0711-S1 - page 2

    2 RS-232/422/ 485 (Port 2) RS-232 (Port 1) DC-In (power) LAN Reset Button LED Indicators (SYS, Port-2, Port-1) Package Contents • 2-Port RS-232/422/485 Serial over IP Ethernet Device Server • Power adapter • Software CD and installation guide Layout Figure 1: Layout • Sys: LED flashes every second when the Serial over IP Ethernet Device Ser ...

  • Siig ID-DS0711-S1 - page 3

    3 Device Server Configuration Follow the instructions below to configure your Serial over IP Ethernet Device Server , if needed. The default IP address of the Serial over IP Ethernet Device Server is 192.168.0.100 . Before you configure the IP of your Serial Device Server , make sure the IP of your PC/NB is in the same network domain as the Serial ...

  • Siig ID-DS0711-S1 - page 4

    4 4. Click the Modify MAC button and change the MAC address from the prompted Dialog Frame window, if needed. 5. Click the Web Browse button to open the Web Browser Configuration webpage. See Figure 6. Figure 4 1. Double click IP Search Utility in the included software CD, then double click CVBrowser... to enable the tool. 2. Click the Refresh butt ...

  • Siig ID-DS0711-S1 - page 5

    5 Type in password and click the Login button, then make your changes from the Web Browser Configuration webpage. See the section for more information. Web Console Configuration In addition to basic IP address and subnet mask, specific device settings can be set through HTTP protocol with popular browsers, e.g. Internet Explorer, Firefox, etc. Setu ...

  • Siig ID-DS0711-S1 - page 6

    6 • Firmware version : The Serial over IP Ethernet Device Server's firmware version is identified by date code. • Serial number : Product serial number as provided by the factory • Ethernet MAC address : The unique MAC (Media Access Control) address used for identification by the Ethernet network • Password and Login : This field is th ...

  • Siig ID-DS0711-S1 - page 7

    7 • Subnet mask : Subnet mask of 255.255.255.0 is usually used for small networks, 255.255.0.0 for larger networks. If your IP address is provided by an ISP or network administrator, please obtain that information and enter it correctly. If DHCP client mode is enabled and there's a DHCP server on the network, this field will be assigned by t ...

  • Siig ID-DS0711-S1 - page 8

    8 Figure 8 • Serial I/O Port 1 (RS-232) : One RS-232 serial port for connecting RS-232 serial device • Serial I/O Port 1 (RS-422/485) : One RS-422/485 serial port for connecting RS-422/485 serial device • Local Port : A socket port assigned to the serial port. It's a 16-bit number, ranging from 1 to 65535. Because the numbers below 1000 ...

  • Siig ID-DS0711-S1 - page 9

    9 • Interface - Port 1 - RS232 GTxD, RxD for data stream, no flow control - RS232 (RTS/CTS) GTxD, RxD for data stream, RTS/CTS for flow control • Interface - Port 2 : The Auto Detect feature will detect the connected serial device's interface as RS-422 or RS-485 automatically - RS485 (Half duplex): Half duplex RS-485 interface, RTS for dri ...

  • Siig ID-DS0711-S1 - page 10

    10 Device Server Updated Press the Update button after you complete your changes. The Serial over IP Ethernet Device Server will save all setting into internal non-volatile memory and then reboot. The Web Console webpage will refresh in around 5 seconds. NOTE : If Controller Updated/Now restarting doesn't show up after clicking the update butt ...

  • Siig ID-DS0711-S1 - page 11

    11 COM Port Setup IMPORTANT : Copy the VirtualCOM folder from your driver CD to your PC's hard drive, then follow the instructions below to add the virtual COM port. 1. Open the VirtualCOM folder, double click 32-bit or 64-bit folder ( based on your system), then double click VSerPortConsole . 2. Enter the VSerPortConsole main menu, right clic ...

  • Siig ID-DS0711-S1 - page 12

    12 4 . Click Install this driver anyway or Continue Anyway , then a COM port would be assigned. 5. Right click under the assigned COM port and click Add Net . Figure 12 COM 3 Add Net 6. Type in the IP address of the Serial over IP Ethernet Device Server in the Remote Address field. 7. Type in the Serial I/O Port's Local port number to the Remo ...

  • Siig ID-DS0711-S1 - page 13

    13 8. A (Unconnceted) TCP Client... will be established. Figure 14 (Unconnected) TCP Client... 9. Right click on the Virtualserial Port Console , click Add Port , then follow steps 3-7 to add the second serial port, if needed. 10. Close the Virtualserial Port Console and reopen it to make sure the COM port is successfully added. 11. Go to the Self- ...

  • Siig ID-DS0711-S1 - page 14

    14 Figure 15 Enter a terminal name, choose an icon, and press OK button. Figure 16 ...

  • Siig ID-DS0711-S1 - page 15

    15 Figure 17 Sele ct the assigned COM port at the Connect using field, see Figure 17 . For example, if the virtual COM port was assigned COM 3, then select COM 3. Figure 18 Select the same values with the Controller Setup to the COMX Properties , then click OK . ...

  • Siig ID-DS0711-S1 - page 16

    16 If Hyper Terminal connects with the Serial over IP Ethernet Device Server successfully, the time clock at the lower left corner, Connected hh:mm:ss , will start counting, see Figure 19 . Figure 19 H yper Terminal for COM Port Initiate another Hyper Terminal as a COM Port Terminal. Select COM 1 or other COM port. Set the COM port properties to th ...

  • Siig ID-DS0711-S1 - page 17

    17 Wiring Architecture PC Ethernet switch / hub RS-232 RS-232 (RTS / CTS) LAN cable Serial Device Rx Tx GND RTS CTS Serial to TCP/IP Tx Rx GND CTS RTS Serial Device Rx Tx GND Serial to TCP/IP Tx Rx GND RS-422 RS-485 Serial Device D - D+ Serial to TCP/IP D - D+ Serial Device Rx- Rx+ Tx- Tx+ Serial to TCP/IP Tx- Tx+ Rx- Rx+ Pin Assignment RS-232 (Por ...

  • Siig ID-DS0711-S1 - page 18

    18 FAQ Q1 . Why can't ETM.exe detect the Serial over IP Ethernet Device Server on the network? A1 . Please check the followings: (1) The power adapter is properly connected and powerd on ; (2) The network cable is properly connected between the Device Server and the computer; (3) The anti-virus program and Firewall utility are disabled; (4) Th ...

  • Siig ID-DS0711-S1 - page 19

    19 Technical Support and Warranty QUESTIONS? SIIG ’ s Online Support has answers! Simply visit our web site at www.siig.com and click Support . Our online support database is updated daily with new drivers and solutions. Answers to your questions could be just a few clicks away. You can also submit questions online and a technical support analyst ...

  • Siig ID-DS0711-S1 - page 20

    About SIIG, Inc. Founded in 1985, SIIG, Inc. is a leading manufacturer of IT connectivity solutions (including Serial ATA and Ultra ATA Controllers, FireWire, USB, and legacy I/O adapters) that bridge the connection between Desktop/ Notebook systems and external peripherals. SIIG continues to grow by adding A/V and Digital Signage connectivity solu ...

Fabricant Siig Catégorie Server

Les documents que nous recevons du fabricant de l'appareilSiig ID-DS0711-S1 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Siig
- manuels d’utilisations ID-DS0711-S1
- fiches produit Siig
- dépliants
- ou étiquettes-énergie Siig ID-DS0711-S1
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Siig ID-DS0711-S1.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Siig ID-DS0711-S1, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Siig ID-DS0711-S1. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Siig ID-DS0711-S1.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Siig ID-DS0711-S1, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Siig ID-DS0711-S1 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Siig ID-DS0711-S1.

Le manuel d’utilisation complet Siig, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Siig ID-DS0711-S1 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Siig ID-DS0711-S1, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSiig ID-DS0711-S1 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Siig ID-DS0711-S1 - qui devraient nous aider dans les premières étapes lors de l'utilisation Siig ID-DS0711-S1
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Siig ID-DS0711-S1
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Siig ID-DS0711-S1 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Siig ID-DS0711-S1?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Siig ID-DS0711-S1, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Siig ID-DS0711-S1 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)