Manuel d’utilisation Delta OIL-FREE AIR COMPRESSOR CP503

20 pages 2.04 mb
Télécharger

Aller à la page of 20

Summary
  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 1

    INSTRUCTION MANUAL P ART NO. A08200 Rev . 0 Copyright © 2004 Delta Machinery T o learn more about DEL T A MACHINER Y visit our website at: www .deltamachinery .com. For Parts, Service, W arranty or other Assistance, please call 1-866-422-4286. Oil-Fr ee Air Compr essor (Model CP503) ESP AÑOL: PÁGINA 21 FRANÇAIS: P AGE 41 ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 2

    2- ENG A08200 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, may result in minor ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 3

    3- ENG A08200 IMPOR T ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all war nings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire How T o Prevent It What Could Happen It is nor ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 4

    4- ENG A08200 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury . How T o Prevent It What Could Happen WARNING: Risk from Flying Objects The compressed air stream can cause soft tissue damage to exposed skin an ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 5

    5- ENG A08200 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution. Electrical Gr ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 6

    6- ENG A08200 WARNING: Risk of Bur ns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 7

    7- ENG A08200 Revie w and unders tand all instructio ns and warnings in this manu al. Becom e famil iar with the oper ation and contr ols of the air comp ress or . Keep operat ing area clear of all persons, pets, and obstacl es. Keep childr en away fr om the air compr essor at all times . Do not operate the produ ct when fatig ued or under the infl ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 8

    8- ENG A08200 Model No. CP503 Running Horsepower 1.5 Bore 1-7/8" Stroke 1-1/4" V olta ge/Hert z/ Phase 120/60/1 Minimum Branch Circuit Requirement 15 amps *Fuse T ype Time Delay Air T ank Capacity 12 gallons Approximate Cut-in Pressur e 100 Approximate Cut-out Pressur e 135 SCFM @ 40 PSIG 4.9 SCFM @ 90 PSIG 3.5 GLOSSAR Y DUTY CYCLE Access ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 9

    INST ALLA TION Location of the Air Compressor Locate the air compr essor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfer e with the flow of air . The air compressor pump and shroud are designed to allow for proper cooling. The ventilation op ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 10

    10- ENG A08200 GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by pr oviding an escape wire for the electric current. This air compressor must be properly grounded. The portable air compr essor is equipped with a cord having a grounding wire with an appr opriate grounding plug (s ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 11

    11- ENG A08200 V oltage and Circuit Protection Refer to the Parts Manual for the voltage and minimum branch circuit requir ements. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met. 1. V oltage supply through branch circuit is 15 amps. 2. Circuit is not used to supply any other electrical needs (lights, ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 12

    12- ENG A08200 OPERA TION Know Y our Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERA TING YOUR UNIT . Compare the illustrations with your unit to familiarize yourself with the location of various contr ols and adjustments. Save this manual for future refer ence. Description of Operation Become familiar with these contr ols b ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 13

    13- ENG A08200 Before Starting Br eak-in Procedur e Serious damage (for units with a tank) may result if the following break-in instructions are not closely followed. This procedur e is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. 1. Make sure the On/Auto/Off lever ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 14

    14- ENG A08200 MAINTENANCE Customer Responsibilities Daily or after each use Before each use Check Safety V alve ● D r ai n T a nk ● T o Check Safety V alve If the safety valve does not work properly , over - pressurization may occur , causing air tank rupture or an explosion. Before starting compressor , pull the ring on the safety valve to ma ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 15

    15- ENG A08200 T o Replace or Clean Check V alve 1. Release all air pr essure from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Loosen the nut on the outlet tube and move the outlet tube to the side. 4. Unscrew the check valve (tur n counterclockwise) using a socket wrench. 5. Make sure the valve disc m ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 16

    16- ENG A08200 T o Replace Regulator 1. Release all air pr essure from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Using an adjustable wr ench remove the gauges and hose from the regulator . 4. Remove the regulator . 5. Apply pipe sealant tape to the nipple on the standpipe. 6. Assemble the regulator a ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 17

    17- ENG A08200 Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur . Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressur e. PROBLEM CAUSE CORRECTION Pressur e switch does not shut off motor when compress ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 18

    18- ENG A08200 Regulator will not shut off air outlet. Damaged regulator . Replace. PROBLEM CAUSE CORRECTION It is normal for "some" pressur e dr op to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 19

    19- ENG A08200 PROBLEM CAUSE CORRECTION Motor will not run. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch cir cuit. Check for proper fuse. Y ou should use a time delay fuse. Check for low voltage problem. Check t ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 20

    20- ENG A08200 A08200 LIMITED W ARRANTY DEL T A MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressur e washers, and generators, which have the following warranty per ...

Fabricant Delta Catégorie Air Compressor

Les documents que nous recevons du fabricant de l'appareilDelta OIL-FREE AIR COMPRESSOR CP503 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Delta
- manuels d’utilisations OIL-FREE AIR COMPRESSOR CP503
- fiches produit Delta
- dépliants
- ou étiquettes-énergie Delta OIL-FREE AIR COMPRESSOR CP503
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Delta OIL-FREE AIR COMPRESSOR CP503.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Delta OIL-FREE AIR COMPRESSOR CP503, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Delta OIL-FREE AIR COMPRESSOR CP503. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Delta OIL-FREE AIR COMPRESSOR CP503.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Delta OIL-FREE AIR COMPRESSOR CP503, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Delta OIL-FREE AIR COMPRESSOR CP503 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Delta OIL-FREE AIR COMPRESSOR CP503.

Le manuel d’utilisation complet Delta, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Delta OIL-FREE AIR COMPRESSOR CP503 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Delta OIL-FREE AIR COMPRESSOR CP503, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lDelta OIL-FREE AIR COMPRESSOR CP503 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Delta OIL-FREE AIR COMPRESSOR CP503 - qui devraient nous aider dans les premières étapes lors de l'utilisation Delta OIL-FREE AIR COMPRESSOR CP503
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Delta OIL-FREE AIR COMPRESSOR CP503
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Delta OIL-FREE AIR COMPRESSOR CP503 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Delta OIL-FREE AIR COMPRESSOR CP503?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Delta OIL-FREE AIR COMPRESSOR CP503, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Delta OIL-FREE AIR COMPRESSOR CP503 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)