Инструкция обслуживания Delta OIL-FREE AIR COMPRESSOR CP503

20 страниц 2.04 mb
Скачать

Перейти на страницу of 20

Summary
  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 1

    INSTRUCTION MANUAL P ART NO. A08200 Rev . 0 Copyright © 2004 Delta Machinery T o learn more about DEL T A MACHINER Y visit our website at: www .deltamachinery .com. For Parts, Service, W arranty or other Assistance, please call 1-866-422-4286. Oil-Fr ee Air Compr essor (Model CP503) ESP AÑOL: PÁGINA 21 FRANÇAIS: P AGE 41 ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 2

    2- ENG A08200 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, may result in minor ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 3

    3- ENG A08200 IMPOR T ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all war nings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire How T o Prevent It What Could Happen It is nor ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 4

    4- ENG A08200 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury . How T o Prevent It What Could Happen WARNING: Risk from Flying Objects The compressed air stream can cause soft tissue damage to exposed skin an ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 5

    5- ENG A08200 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution. Electrical Gr ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 6

    6- ENG A08200 WARNING: Risk of Bur ns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 7

    7- ENG A08200 Revie w and unders tand all instructio ns and warnings in this manu al. Becom e famil iar with the oper ation and contr ols of the air comp ress or . Keep operat ing area clear of all persons, pets, and obstacl es. Keep childr en away fr om the air compr essor at all times . Do not operate the produ ct when fatig ued or under the infl ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 8

    8- ENG A08200 Model No. CP503 Running Horsepower 1.5 Bore 1-7/8" Stroke 1-1/4" V olta ge/Hert z/ Phase 120/60/1 Minimum Branch Circuit Requirement 15 amps *Fuse T ype Time Delay Air T ank Capacity 12 gallons Approximate Cut-in Pressur e 100 Approximate Cut-out Pressur e 135 SCFM @ 40 PSIG 4.9 SCFM @ 90 PSIG 3.5 GLOSSAR Y DUTY CYCLE Access ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 9

    INST ALLA TION Location of the Air Compressor Locate the air compr essor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfer e with the flow of air . The air compressor pump and shroud are designed to allow for proper cooling. The ventilation op ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 10

    10- ENG A08200 GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by pr oviding an escape wire for the electric current. This air compressor must be properly grounded. The portable air compr essor is equipped with a cord having a grounding wire with an appr opriate grounding plug (s ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 11

    11- ENG A08200 V oltage and Circuit Protection Refer to the Parts Manual for the voltage and minimum branch circuit requir ements. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met. 1. V oltage supply through branch circuit is 15 amps. 2. Circuit is not used to supply any other electrical needs (lights, ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 12

    12- ENG A08200 OPERA TION Know Y our Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERA TING YOUR UNIT . Compare the illustrations with your unit to familiarize yourself with the location of various contr ols and adjustments. Save this manual for future refer ence. Description of Operation Become familiar with these contr ols b ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 13

    13- ENG A08200 Before Starting Br eak-in Procedur e Serious damage (for units with a tank) may result if the following break-in instructions are not closely followed. This procedur e is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. 1. Make sure the On/Auto/Off lever ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 14

    14- ENG A08200 MAINTENANCE Customer Responsibilities Daily or after each use Before each use Check Safety V alve ● D r ai n T a nk ● T o Check Safety V alve If the safety valve does not work properly , over - pressurization may occur , causing air tank rupture or an explosion. Before starting compressor , pull the ring on the safety valve to ma ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 15

    15- ENG A08200 T o Replace or Clean Check V alve 1. Release all air pr essure from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Loosen the nut on the outlet tube and move the outlet tube to the side. 4. Unscrew the check valve (tur n counterclockwise) using a socket wrench. 5. Make sure the valve disc m ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 16

    16- ENG A08200 T o Replace Regulator 1. Release all air pr essure from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Using an adjustable wr ench remove the gauges and hose from the regulator . 4. Remove the regulator . 5. Apply pipe sealant tape to the nipple on the standpipe. 6. Assemble the regulator a ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 17

    17- ENG A08200 Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur . Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressur e. PROBLEM CAUSE CORRECTION Pressur e switch does not shut off motor when compress ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 18

    18- ENG A08200 Regulator will not shut off air outlet. Damaged regulator . Replace. PROBLEM CAUSE CORRECTION It is normal for "some" pressur e dr op to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 19

    19- ENG A08200 PROBLEM CAUSE CORRECTION Motor will not run. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch cir cuit. Check for proper fuse. Y ou should use a time delay fuse. Check for low voltage problem. Check t ...

  • Delta OIL-FREE AIR COMPRESSOR CP503 - page 20

    20- ENG A08200 A08200 LIMITED W ARRANTY DEL T A MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressur e washers, and generators, which have the following warranty per ...

Производитель Delta Категория Air Compressor

Документы, которые мы получаем от производителя устройства Delta OIL-FREE AIR COMPRESSOR CP503 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Delta
- инструкции обслуживания OIL-FREE AIR COMPRESSOR CP503
- паспорта изделия Delta
- информационные брошюры
- энергетические этикетки Delta OIL-FREE AIR COMPRESSOR CP503
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Delta OIL-FREE AIR COMPRESSOR CP503.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Delta OIL-FREE AIR COMPRESSOR CP503, инструкции обслуживания, короткие инструкции или инструкции пользователя Delta OIL-FREE AIR COMPRESSOR CP503. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Delta OIL-FREE AIR COMPRESSOR CP503.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Delta OIL-FREE AIR COMPRESSOR CP503, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Delta OIL-FREE AIR COMPRESSOR CP503 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Delta OIL-FREE AIR COMPRESSOR CP503.

Полная инструкция обслуживания Delta, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Delta OIL-FREE AIR COMPRESSOR CP503 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Delta OIL-FREE AIR COMPRESSOR CP503, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Delta OIL-FREE AIR COMPRESSOR CP503, которое найдем в данном документе
3. Советы по использованию основных функций устройства Delta OIL-FREE AIR COMPRESSOR CP503 - которые должны облегчить нам первые шаги во время использования Delta OIL-FREE AIR COMPRESSOR CP503
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Delta OIL-FREE AIR COMPRESSOR CP503
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Delta OIL-FREE AIR COMPRESSOR CP503 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Delta OIL-FREE AIR COMPRESSOR CP503?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Delta OIL-FREE AIR COMPRESSOR CP503, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Delta OIL-FREE AIR COMPRESSOR CP503 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)