    ST 3000 Smart Transmitter Series 900 Remote Diaphragm Seals Models STR93D 0 to 100 psid 0 to 7 bar STR94G 0 to 500 psig 0 to 35 bar 34-ST-03-57 3/07 Specification and Model Selection Guide In 1983, Honeywell introduced the first Smart Pressure Transmitter ― the ST 3000 ® . In 1989, Honeywell laun ched the first all digital, bi-directional protoc ...

  • Honeywell STR93D - page 2

    34-ST-03-57 Page 2 Description of Diaphragm Seals Diaphragm seals are traditionally used whe n a standa rd pressure transmitter should not be e xposed to the process pressure directly. Diaphrag m seals typically protect the pressure transmitter from one or more damaging aspect s of the process media. Consideration for using a diaphragm seal should ...

  • Honeywell STR93D - page 3

    34-ST-03-57 Page 3 Description of Diaphragm Seals Figure 6 - Seals with Threaded Process Connections can be use d with differential, gauge and absolute pressure transmitters and are a vailable with ½”, ¾” and 1” NPT Female process con nections. Figure 6 Figure 7 - Sanitary Seals can be used with differential, gauge and absolute pressu re tr ...

  • Honeywell STR93D - page 4

    34-ST-03-57 Page 4 Figure 12 - Welded Meter Body for All-Welded Remote Seal Solution. The welded ST 3000 meter body is an important part of an All-Welded Rem ote Seal Solution, which is commonly used in Vacuum applications. Figure 12 Description Features The ST 3000 transmitter can replace any 4 to 20 mA output transmitter in use today and operates ...

  • Honeywell STR93D - page 5

    34-ST-03-57 Page 5 Specifications Operating Conditions – All Models Parameter Reference Condition (at zero static) Rated Condition Operative Limits Transportation and Storage °C °F °C °F °C °F °C °F Ambient Temperature 25 ±1 77 ±2 -25 to 70 -13 to 158 -40 to 85 -40 to 185 -55 to 125 -67 to 257 Process Interface Temperature 25 ±1 77 ±2 ...

  • Honeywell STR93D - page 6

    34-ST-03-57 Page 6 1Atm Special High Vacuum Construction required. Consult STC. 9000 8000 7000 6000 5000 4000 3000 2000 1000 Maximum Pressure Limited by Flange Rating of Seal 10000 900 800 700 600 500 400 300 200 100 90 80 70 60 50 40 30 20 10 Pressure (mmHgA) -40 52 5 3 0 0 100 175 350 450 200 300 400 500 psig 193 -9 psig -14 psig Process Temperat ...

  • Honeywell STR93D - page 7

    34-ST-03-57 Page 7 Note: A min imum of 250 ohms of loop re sistance is necessary to support communicat ions. Loop resistance equals ba rrier resistance plu s wire res istance plus rece iver resistanc e. = Operating Area 0 10.8 16.28 20.63 25 28.3 37.0 42.4 1440 1200 800 650 450 250 Operating Volta ge (Vdc) Loop Resistan ce (ohms) Note: A min imum o ...

  • Honeywell STR93D - page 8

    34-ST-03-57 Page 8 Performance Under Rated Conditions * - Models STR94G (0 to 500 psi/35 bar) Parameter Description Upper Range Limit psi bar 500 35 Minimum Span psi bar 20 1.4 Turndown Ratio 25 to 1 Zero Elevation a nd Suppress ion No limit except minimum sp an from absolute 0 (zero) to +100% URL. Accuracy (Reference – Includes combined effect s ...

  • Honeywell STR93D - page 9

    34-ST-03-57 Page 9 Physical and Approval Bodies Parameter Description Process Interface See Model Selection Guide f or Material Options for desir ed Seal Type. Seal Barrier Diaphragm 316L Stainless Steel, Monel, Hast elloy C, Tant alum Seal Gasket Materials Klinger C-4 401 (non-asbestos) Grafoil Tef lon Gylon 3510 Mounting Bracket Carbon Steel (zin ...

  • Honeywell STR93D - page 10

    34-ST-03-57 Page 10 Parameter Description Pressure Equipment Directive (97/23/EC) The ST 3000 pressure t ransmitters listed in t his Specificatio n have no pressurized internal volume or have a pr essurized internal volume rated less than 1,0 00 bar (14,500 psig) and/ or have a maximum volum e of less than 0.1 liter. Therefore, these transmitt ers ...

  • Honeywell STR93D - page 11

    34-ST-03-57 Page 11 Application Data Liquid Level: Closed Tank Determine the minimum and maximum pressure differentials to be measured (Figure 17). P Min = (SG p x a) - (SG f x d) = LRV when HP at bottom of tank = –URV when LP at bottom of tank P Max = (SG p x b) - (SG f x d) = URV when HP at bottom of tank = –LRV when LP at bottom of tank Wher ...

  • Honeywell STR93D - page 12

    34-ST-03-57 Page 12 Density or Interface Calculate the minimum and maximum pressure differentials to be measured (Figure 18). P min = (SG min – SG f ) x (d); minimum density, 4mA output P max = (SG max – SG f ) x (d); maximum density, 20mA output Where: d = distance between the taps SG max = maximum Specific Gravity SG min = minimum Specific Gr ...

  • Honeywell STR93D - page 13

    34-ST-03-57 Page 13 Reference Dimensions: millimeters Inches STR93D DP/I Remote Seal with Horizontal Pipe Mount STR94G LGP/I Remote Seal with Horizontal Pipe Mount 24272 Seal omitted for clarity with meter Optional external ground 45.7 1.8 53.1 2.09 Removal Clearance for All Caps 82.9 3.26 With Smart meter Without meter 94.9 3.74 65.1 2.56 Without ...

  • Honeywell STR93D - page 14

    34-ST-03-57 Page 14 Reference Dimensions: millimeters Inches Seal omi t t ed f o r clar it y Optional ex te rnal ground wi th mete r 45. 7 1. 8 53. 1 2. 09 Rem ov al Cl ea r anc e fo r A l l C ap s 82. 9 3. 2 6 Wi th Smar t m eter Wi t h o u t meter 94. 9 3. 7 4 65. 1 2. 5 6 W ith out meter 23. 5 .925 S TR 93 D DP /I Re mote Sea l w it h Ve rti cal ...

  • Honeywell STR93D - page 15

    34-ST-03-57 Page 15 Options Ordering Information Mounting Bracket The angle-mounting bracket is available in either zinc-plat ed carbon steel or stainless st eel and is suitable for horizontal or vertical mounting on a two-inch (50 millimeter) pipe, as well as wall mounting. An optional flat mounting bracket is also available in carbon steel for tw ...

  • Honeywell STR93D - page 16

    34-ST-03-57 Page 16 Model Selection Guide (34-ST-16-34) Instructions • Select the desired Key Number. The arrow to the right mar ks the selection availab le. • Make one selection from ea ch table, I and I I, using the column below the proper ar row. • S elect as many Tab le III options as de sired (if no opt i ons are desir ed, specify 9 X). ...

  • Honeywell STR93D - page 17

    34-ST-03-57 Page 17 TA BLE II - SEA LS Format for Seal Selection: Specify 12 ch aracter s _ _ _ _ _ _ _ _ _ _ _ _ Avai l a bi l it y Common Required Seal STR9xx Note: T he firs t 3 char acters ar e common t o all sea ls. When selecti ng required seal, yo u must specify 3D 4G only the 9 selec tions within t he requir ed seal. 0 _ _ _ _ _ _ _ _ _ _ _ ...

  • Honeywell STR93D - page 18

    34-ST-03-57 Page 18 A vai lability STR9xx TABLE II - SEA LS (continued) 3D 4G None _ _ _ _ _ _ _ _ _ _ _ 0 •• One 1/4" wi th plastic plug _ _ _ _ _ _ _ _ _ _ _ H 66 One 1/4" wi th metal plug _ _ _ _ _ _ _ _ _ _ _ J 66 Metal plug material Two 1/4" with plastic plugs _ _ _ _ _ _ _ _ _ _ _ M 66 will be the sam e as Two 1/4" wit ...

  • Honeywell STR93D - page 19

    34-ST-03-57 Page 19 A v ailability STR9xx TA BLE II - SEA LS (continued) 3D 4G Diaphragm Low er _ _ _ _ _ _ BA _ _ _ _ •• _ _ _ _ _ _ BB _ _ _ _ •• _ _ _ _ _ _ BC _ _ _ _ •• _ _ _ _ _ _ BE _ _ _ _ •• _ _ _ _ _ _ BF _ _ _ _ 11 _ _ _ _ _ _ BG _ _ _ _ 11 _ _ _ _ _ _ BH _ _ _ _ 10 10 Upper Upper Insert _ _ _ _ _ _ _ _ 4 _ _ _ •• _ _ ...

  • Honeywell STR93D - page 20

    34-ST-03-57 Page 20 STR9xx TA BLE II - SEALS (continued) 3D 4 G 3.5" 3" _ _ _ GFA _ _ _ _ _ _ •• Diaphragm Body _ _ _ _ _ _ GA _ _ _ _ •• _ _ _ _ _ _ GB _ _ _ _ •• _ _ _ _ _ _ GC _ _ _ _ •• _ _ _ _ _ _ GE _ _ _ _ •• _ _ _ _ _ _ GG _ _ _ _ 11 _ _ _ _ _ _ _ _ 0 _ _ _ •• _ _ _ _ _ _ _ _ _ 0 _ _ •• _ _ _ _ _ _ _ _ ...

  • Honeywell STR93D - page 21

    34-ST-03-57 Page 21 A vailability STR9xx TAB LE II - SEA LS (continued) 3D 4G _ _ _ JJG _ _ _ _ _ _ •• _ _ _ JKG _ _ _ _ _ _ •• _ _ _ JLG _ _ _ _ _ _ •• _ _ _ KJG _ _ _ _ _ _ •• _ _ _ KKG _ _ _ _ _ _ •• _ _ _ KLG _ _ _ _ _ _ •• _ _ _ LJG _ _ _ _ _ _ •• _ _ _ LKG _ _ _ _ _ _ •• _ _ _ LLG _ _ _ _ _ _ •• Diaphrag m ...

  • Honeywell STR93D - page 22

    34-ST-03-57 Page 22 STR9xx TA BLE II - SEA LS (continued) 3D 4G 1.9" 2" _ _ _ MD0 _ _ _ _ _ _ g • 2.4" 2-1/2" _ _ _ NE0 _ _ _ _ _ _ •• 2.9" 3" _ _ _ PF0 _ _ _ _ _ _ •• 4.1" 4" _ _ _ QG0 _ _ _ _ _ _ •• Diaphragm Body _ _ _ _ _ _ N A _ _ _ _ •• •• •• _ _ _ _ _ _ _ _ _ 0 _ _ •• _ _ ...

  • Honeywell STR93D - page 23

    34-ST-03-57 Page 23 STR9xx TAB L E III - OPTIONS Selection 3D 4G None 00 •• Communication Options HART 5.x Protocol Compatible Electronics HC ee H6 ee FOUNDATION Fieldbus Communications FF rr Indicating Meter Options Analog Meter (0-100 Even 0-10 Square Root) ME •• Smart Meter SM •• Custom Configuration of Smart Meter CI mm Local Zero L ...

  • Honeywell STR93D - page 24

    34-ST-03-57 Page 24 STR9xx TA BLE III - OPTIONS (continued) 3D 4G 9X •  Multiple Marki ng** Int. Safe, Zone 0/1, or Flameproof, Zone 1, or Non-Sparking, Zone 2 *See ATEX installation requi rements in the ST 300 0 User's Manual TABLE IV Factory I den tification XXXX •• **The user must determine the type of protection required for insta ...

  • Honeywell STR93D - page 25

    34-ST-03-57 Page 25 RESTRICT IONS Restriction Letter Table Table Selection b _ _ _ _ _ _ BF _ _ _ _, _ _ _ _ _ _ BG _ _ _ _, _ _ _ _ _ _ BH _ _ _ _, _ _ _ _ _ _ JF _ _ _ _, _ _ _ _ _ _ JG _ _ _ _, _ _ _ _ _ _ BF _ _ _ _, _ _ _ _ _ _ BG _ _ _ _, _ _ _ _ _ _ JF _ _ _ _, _ _ _ _ _ _ JG _ _ _ _, e 4G _ A _ _ _ _ _ _ _ _ _ _, _ B _ _ _ _ _ _ _ _ _ _, _ ...

  • Honeywell STR93D - page 26

    34-ST-03-57 Page 26 RESTRI CTIO NS - (co ntin ued) Table Table Selectio n u 1C, 2J v 2 _ _ w _ _ _ _ _ _ JA _ _ _ _ x FF, SM MB, SB, FB _ _ _ BCA _ _ 5 _ _ _, _ _ _ CAA _ _ 5 _ _ _, _ _ _ CCA _ _ 5 _ _ _, _ _ _ CCC _ _ 5 _ _ _, _ _ _ DAA _ _ 5 _ _ _, _ _ _ DCA _ _ 5 _ _ _, _ _ _ DCC _ _ 5 _ _ _, _ _ _ DGA _ _ 5 _ _ _, _ _ _ DGC _ _ 5 _ _ _, _ _ _ D ...

  • Honeywell STR93D - page 27

    34-ST-03-57 Page 27 Dimensions and drawings Figure 20 a. Fl ush Fl a n ge d Se al Figure 20 b. Fl ush Fl a n ge d Seal 20a 20b 20b 20a 20a 20a 20a 20b 20b 20a 20a 20a 20a 20b 20b 20a 20a 20a 20a 20b 20b 20a 20a 20a Figure 21 a. Fl ush Fl a n ge d Se al Figure 21 b. Fl ush Fl a n ge d Seal 21a 21b 21b 21a 21a 21a 21a 21b 21b 21a 21a 21a 21a 21b 21b ...

  • Honeywell STR93D - page 28

    34-ST-03-57 Page 28 Dimensions and drawings, cont. Figure 21 Figure 22 Figure 22 Figure 23 ...

  • Honeywell STR93D - page 29

    34-ST-03-57 Page 29 Dimensions and drawings, cont. Figure 23 Figure 24 Figure 25 Figure 24 Figure 25 Figure 26 ...

  • Honeywell STR93D - page 30

    34-ST-03-57 Page 30 Dimensions and drawings, cont. Figure 26 Figure 27 Figure 27 Figure 28 ...

  • Honeywell STR93D - page 31

    34-ST-03-57 Page 31 Dimensions and drawings, cont. Figure 28 Figure 29 Figure 29 Figure 30 Figure 20 Figure 20 Figure 30 Figure 20 Figure 20 Figure 31 ...

  • Honeywell STR93D - page 32

    34-ST-03-57 Page 32 ST 3000 ® is a registered trademark of Honeywell International Inc. FOUNDATION ™ is a trademark of the Fieldbus Foun dation. HART* is a trademark of the Ha rt Communication Foundation. Honeywell Process Solutio ns Industrial Measurement a nd Control Honeywell International Inc. 2500 W. Union Hill Drive Phoenix, Arizona 85027 ...

Fabricant Honeywell Catégorie Satellite Radio

Les documents que nous recevons du fabricant de l'appareilHoneywell STR93D peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Honeywell
- manuels d’utilisations STR93D
- fiches produit Honeywell
- dépliants
- ou étiquettes-énergie Honeywell STR93D
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Honeywell STR93D.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Honeywell STR93D, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Honeywell STR93D. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Honeywell STR93D.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Honeywell STR93D, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Honeywell STR93D par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Honeywell STR93D.

Le manuel d’utilisation complet Honeywell, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Honeywell STR93D - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Honeywell STR93D, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHoneywell STR93D qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Honeywell STR93D - qui devraient nous aider dans les premières étapes lors de l'utilisation Honeywell STR93D
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Honeywell STR93D
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Honeywell STR93D dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Honeywell STR93D?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Honeywell STR93D, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Honeywell STR93D il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)