    ST 3000 Smart Transmitter Series 900 Remote Diaphragm Seals Models STR93D 0 to 100 psid 0 to 7 bar STR94G 0 to 500 psig 0 to 35 bar 34-ST-03-57 3/07 Specification and Model Selection Guide In 1983, Honeywell introduced the first Smart Pressure Transmitter ― the ST 3000 ® . In 1989, Honeywell laun ched the first all digital, bi-directional protoc ...

  • Honeywell STR93D - page 2

    34-ST-03-57 Page 2 Description of Diaphragm Seals Diaphragm seals are traditionally used whe n a standa rd pressure transmitter should not be e xposed to the process pressure directly. Diaphrag m seals typically protect the pressure transmitter from one or more damaging aspect s of the process media. Consideration for using a diaphragm seal should ...

  • Honeywell STR93D - page 3

    34-ST-03-57 Page 3 Description of Diaphragm Seals Figure 6 - Seals with Threaded Process Connections can be use d with differential, gauge and absolute pressure transmitters and are a vailable with ½”, ¾” and 1” NPT Female process con nections. Figure 6 Figure 7 - Sanitary Seals can be used with differential, gauge and absolute pressu re tr ...

  • Honeywell STR93D - page 4

    34-ST-03-57 Page 4 Figure 12 - Welded Meter Body for All-Welded Remote Seal Solution. The welded ST 3000 meter body is an important part of an All-Welded Rem ote Seal Solution, which is commonly used in Vacuum applications. Figure 12 Description Features The ST 3000 transmitter can replace any 4 to 20 mA output transmitter in use today and operates ...

  • Honeywell STR93D - page 5

    34-ST-03-57 Page 5 Specifications Operating Conditions – All Models Parameter Reference Condition (at zero static) Rated Condition Operative Limits Transportation and Storage °C °F °C °F °C °F °C °F Ambient Temperature 25 ±1 77 ±2 -25 to 70 -13 to 158 -40 to 85 -40 to 185 -55 to 125 -67 to 257 Process Interface Temperature 25 ±1 77 ±2 ...

  • Honeywell STR93D - page 6

    34-ST-03-57 Page 6 1Atm Special High Vacuum Construction required. Consult STC. 9000 8000 7000 6000 5000 4000 3000 2000 1000 Maximum Pressure Limited by Flange Rating of Seal 10000 900 800 700 600 500 400 300 200 100 90 80 70 60 50 40 30 20 10 Pressure (mmHgA) -40 52 5 3 0 0 100 175 350 450 200 300 400 500 psig 193 -9 psig -14 psig Process Temperat ...

  • Honeywell STR93D - page 7

    34-ST-03-57 Page 7 Note: A min imum of 250 ohms of loop re sistance is necessary to support communicat ions. Loop resistance equals ba rrier resistance plu s wire res istance plus rece iver resistanc e. = Operating Area 0 10.8 16.28 20.63 25 28.3 37.0 42.4 1440 1200 800 650 450 250 Operating Volta ge (Vdc) Loop Resistan ce (ohms) Note: A min imum o ...

  • Honeywell STR93D - page 8

    34-ST-03-57 Page 8 Performance Under Rated Conditions * - Models STR94G (0 to 500 psi/35 bar) Parameter Description Upper Range Limit psi bar 500 35 Minimum Span psi bar 20 1.4 Turndown Ratio 25 to 1 Zero Elevation a nd Suppress ion No limit except minimum sp an from absolute 0 (zero) to +100% URL. Accuracy (Reference – Includes combined effect s ...

  • Honeywell STR93D - page 9

    34-ST-03-57 Page 9 Physical and Approval Bodies Parameter Description Process Interface See Model Selection Guide f or Material Options for desir ed Seal Type. Seal Barrier Diaphragm 316L Stainless Steel, Monel, Hast elloy C, Tant alum Seal Gasket Materials Klinger C-4 401 (non-asbestos) Grafoil Tef lon Gylon 3510 Mounting Bracket Carbon Steel (zin ...

  • Honeywell STR93D - page 10

    34-ST-03-57 Page 10 Parameter Description Pressure Equipment Directive (97/23/EC) The ST 3000 pressure t ransmitters listed in t his Specificatio n have no pressurized internal volume or have a pr essurized internal volume rated less than 1,0 00 bar (14,500 psig) and/ or have a maximum volum e of less than 0.1 liter. Therefore, these transmitt ers ...

  • Honeywell STR93D - page 11

    34-ST-03-57 Page 11 Application Data Liquid Level: Closed Tank Determine the minimum and maximum pressure differentials to be measured (Figure 17). P Min = (SG p x a) - (SG f x d) = LRV when HP at bottom of tank = –URV when LP at bottom of tank P Max = (SG p x b) - (SG f x d) = URV when HP at bottom of tank = –LRV when LP at bottom of tank Wher ...

  • Honeywell STR93D - page 12

    34-ST-03-57 Page 12 Density or Interface Calculate the minimum and maximum pressure differentials to be measured (Figure 18). P min = (SG min – SG f ) x (d); minimum density, 4mA output P max = (SG max – SG f ) x (d); maximum density, 20mA output Where: d = distance between the taps SG max = maximum Specific Gravity SG min = minimum Specific Gr ...

  • Honeywell STR93D - page 13

    34-ST-03-57 Page 13 Reference Dimensions: millimeters Inches STR93D DP/I Remote Seal with Horizontal Pipe Mount STR94G LGP/I Remote Seal with Horizontal Pipe Mount 24272 Seal omitted for clarity with meter Optional external ground 45.7 1.8 53.1 2.09 Removal Clearance for All Caps 82.9 3.26 With Smart meter Without meter 94.9 3.74 65.1 2.56 Without ...

  • Honeywell STR93D - page 14

    34-ST-03-57 Page 14 Reference Dimensions: millimeters Inches Seal omi t t ed f o r clar it y Optional ex te rnal ground wi th mete r 45. 7 1. 8 53. 1 2. 09 Rem ov al Cl ea r anc e fo r A l l C ap s 82. 9 3. 2 6 Wi th Smar t m eter Wi t h o u t meter 94. 9 3. 7 4 65. 1 2. 5 6 W ith out meter 23. 5 .925 S TR 93 D DP /I Re mote Sea l w it h Ve rti cal ...

  • Honeywell STR93D - page 15

    34-ST-03-57 Page 15 Options Ordering Information Mounting Bracket The angle-mounting bracket is available in either zinc-plat ed carbon steel or stainless st eel and is suitable for horizontal or vertical mounting on a two-inch (50 millimeter) pipe, as well as wall mounting. An optional flat mounting bracket is also available in carbon steel for tw ...

  • Honeywell STR93D - page 16

    34-ST-03-57 Page 16 Model Selection Guide (34-ST-16-34) Instructions • Select the desired Key Number. The arrow to the right mar ks the selection availab le. • Make one selection from ea ch table, I and I I, using the column below the proper ar row. • S elect as many Tab le III options as de sired (if no opt i ons are desir ed, specify 9 X). ...

  • Honeywell STR93D - page 17

    34-ST-03-57 Page 17 TA BLE II - SEA LS Format for Seal Selection: Specify 12 ch aracter s _ _ _ _ _ _ _ _ _ _ _ _ Avai l a bi l it y Common Required Seal STR9xx Note: T he firs t 3 char acters ar e common t o all sea ls. When selecti ng required seal, yo u must specify 3D 4G only the 9 selec tions within t he requir ed seal. 0 _ _ _ _ _ _ _ _ _ _ _ ...

  • Honeywell STR93D - page 18

    34-ST-03-57 Page 18 A vai lability STR9xx TABLE II - SEA LS (continued) 3D 4G None _ _ _ _ _ _ _ _ _ _ _ 0 •• One 1/4" wi th plastic plug _ _ _ _ _ _ _ _ _ _ _ H 66 One 1/4" wi th metal plug _ _ _ _ _ _ _ _ _ _ _ J 66 Metal plug material Two 1/4" with plastic plugs _ _ _ _ _ _ _ _ _ _ _ M 66 will be the sam e as Two 1/4" wit ...

  • Honeywell STR93D - page 19

    34-ST-03-57 Page 19 A v ailability STR9xx TA BLE II - SEA LS (continued) 3D 4G Diaphragm Low er _ _ _ _ _ _ BA _ _ _ _ •• _ _ _ _ _ _ BB _ _ _ _ •• _ _ _ _ _ _ BC _ _ _ _ •• _ _ _ _ _ _ BE _ _ _ _ •• _ _ _ _ _ _ BF _ _ _ _ 11 _ _ _ _ _ _ BG _ _ _ _ 11 _ _ _ _ _ _ BH _ _ _ _ 10 10 Upper Upper Insert _ _ _ _ _ _ _ _ 4 _ _ _ •• _ _ ...

  • Honeywell STR93D - page 20

    34-ST-03-57 Page 20 STR9xx TA BLE II - SEALS (continued) 3D 4 G 3.5" 3" _ _ _ GFA _ _ _ _ _ _ •• Diaphragm Body _ _ _ _ _ _ GA _ _ _ _ •• _ _ _ _ _ _ GB _ _ _ _ •• _ _ _ _ _ _ GC _ _ _ _ •• _ _ _ _ _ _ GE _ _ _ _ •• _ _ _ _ _ _ GG _ _ _ _ 11 _ _ _ _ _ _ _ _ 0 _ _ _ •• _ _ _ _ _ _ _ _ _ 0 _ _ •• _ _ _ _ _ _ _ _ ...

  • Honeywell STR93D - page 21

    34-ST-03-57 Page 21 A vailability STR9xx TAB LE II - SEA LS (continued) 3D 4G _ _ _ JJG _ _ _ _ _ _ •• _ _ _ JKG _ _ _ _ _ _ •• _ _ _ JLG _ _ _ _ _ _ •• _ _ _ KJG _ _ _ _ _ _ •• _ _ _ KKG _ _ _ _ _ _ •• _ _ _ KLG _ _ _ _ _ _ •• _ _ _ LJG _ _ _ _ _ _ •• _ _ _ LKG _ _ _ _ _ _ •• _ _ _ LLG _ _ _ _ _ _ •• Diaphrag m ...

  • Honeywell STR93D - page 22

    34-ST-03-57 Page 22 STR9xx TA BLE II - SEA LS (continued) 3D 4G 1.9" 2" _ _ _ MD0 _ _ _ _ _ _ g • 2.4" 2-1/2" _ _ _ NE0 _ _ _ _ _ _ •• 2.9" 3" _ _ _ PF0 _ _ _ _ _ _ •• 4.1" 4" _ _ _ QG0 _ _ _ _ _ _ •• Diaphragm Body _ _ _ _ _ _ N A _ _ _ _ •• •• •• _ _ _ _ _ _ _ _ _ 0 _ _ •• _ _ ...

  • Honeywell STR93D - page 23

    34-ST-03-57 Page 23 STR9xx TAB L E III - OPTIONS Selection 3D 4G None 00 •• Communication Options HART 5.x Protocol Compatible Electronics HC ee H6 ee FOUNDATION Fieldbus Communications FF rr Indicating Meter Options Analog Meter (0-100 Even 0-10 Square Root) ME •• Smart Meter SM •• Custom Configuration of Smart Meter CI mm Local Zero L ...

  • Honeywell STR93D - page 24

    34-ST-03-57 Page 24 STR9xx TA BLE III - OPTIONS (continued) 3D 4G 9X •  Multiple Marki ng** Int. Safe, Zone 0/1, or Flameproof, Zone 1, or Non-Sparking, Zone 2 *See ATEX installation requi rements in the ST 300 0 User's Manual TABLE IV Factory I den tification XXXX •• **The user must determine the type of protection required for insta ...

  • Honeywell STR93D - page 25

    34-ST-03-57 Page 25 RESTRICT IONS Restriction Letter Table Table Selection b _ _ _ _ _ _ BF _ _ _ _, _ _ _ _ _ _ BG _ _ _ _, _ _ _ _ _ _ BH _ _ _ _, _ _ _ _ _ _ JF _ _ _ _, _ _ _ _ _ _ JG _ _ _ _, _ _ _ _ _ _ BF _ _ _ _, _ _ _ _ _ _ BG _ _ _ _, _ _ _ _ _ _ JF _ _ _ _, _ _ _ _ _ _ JG _ _ _ _, e 4G _ A _ _ _ _ _ _ _ _ _ _, _ B _ _ _ _ _ _ _ _ _ _, _ ...

  • Honeywell STR93D - page 26

    34-ST-03-57 Page 26 RESTRI CTIO NS - (co ntin ued) Table Table Selectio n u 1C, 2J v 2 _ _ w _ _ _ _ _ _ JA _ _ _ _ x FF, SM MB, SB, FB _ _ _ BCA _ _ 5 _ _ _, _ _ _ CAA _ _ 5 _ _ _, _ _ _ CCA _ _ 5 _ _ _, _ _ _ CCC _ _ 5 _ _ _, _ _ _ DAA _ _ 5 _ _ _, _ _ _ DCA _ _ 5 _ _ _, _ _ _ DCC _ _ 5 _ _ _, _ _ _ DGA _ _ 5 _ _ _, _ _ _ DGC _ _ 5 _ _ _, _ _ _ D ...

  • Honeywell STR93D - page 27

    34-ST-03-57 Page 27 Dimensions and drawings Figure 20 a. Fl ush Fl a n ge d Se al Figure 20 b. Fl ush Fl a n ge d Seal 20a 20b 20b 20a 20a 20a 20a 20b 20b 20a 20a 20a 20a 20b 20b 20a 20a 20a 20a 20b 20b 20a 20a 20a Figure 21 a. Fl ush Fl a n ge d Se al Figure 21 b. Fl ush Fl a n ge d Seal 21a 21b 21b 21a 21a 21a 21a 21b 21b 21a 21a 21a 21a 21b 21b ...

  • Honeywell STR93D - page 28

    34-ST-03-57 Page 28 Dimensions and drawings, cont. Figure 21 Figure 22 Figure 22 Figure 23 ...

  • Honeywell STR93D - page 29

    34-ST-03-57 Page 29 Dimensions and drawings, cont. Figure 23 Figure 24 Figure 25 Figure 24 Figure 25 Figure 26 ...

  • Honeywell STR93D - page 30

    34-ST-03-57 Page 30 Dimensions and drawings, cont. Figure 26 Figure 27 Figure 27 Figure 28 ...

  • Honeywell STR93D - page 31

    34-ST-03-57 Page 31 Dimensions and drawings, cont. Figure 28 Figure 29 Figure 29 Figure 30 Figure 20 Figure 20 Figure 30 Figure 20 Figure 20 Figure 31 ...

  • Honeywell STR93D - page 32

    34-ST-03-57 Page 32 ST 3000 ® is a registered trademark of Honeywell International Inc. FOUNDATION ™ is a trademark of the Fieldbus Foun dation. HART* is a trademark of the Ha rt Communication Foundation. Honeywell Process Solutio ns Industrial Measurement a nd Control Honeywell International Inc. 2500 W. Union Hill Drive Phoenix, Arizona 85027 ...

Fabbricante Honeywell Categoria Satellite Radio

I documenti che otteniamo dal fabbricante del dispositivoHoneywell STR93D possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Honeywell
- manuali per l’uso STR93D
- schede prodotto Honeywell
- opuscoli
- o etichette energetiche Honeywell STR93D
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Honeywell STR93D.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Honeywell STR93D, manuali di manutenzione, brevi manuali o manuali utente Honeywell STR93D. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Honeywell STR93D.

Manuali per l’uso simili

Manuale completo del dispositivo Honeywell STR93D, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Honeywell STR93D dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Honeywell STR93D.

Il manuale per l’uso completo Honeywell, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Honeywell STR93D - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Honeywell STR93D, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Honeywell STR93D che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Honeywell STR93D - che ci dovrebbe aiutare nei primi passi durante l'uso Honeywell STR93D
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Honeywell STR93D
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Honeywell STR93D in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Honeywell STR93D?

Utilizza il modulo sottostante

Se non hai risolto il problema con Honeywell STR93D con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Honeywell STR93D è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)