  • New Buck Corporation 42ZCBB - page 1

    New Buck Corporation Revised: November 2004 P.O. Box 69 8000 Hwy. 226 Sou th Spruce Pine, NC 28777 BUCK ST OVE MODEL 42ZCBB VENTLESS FIREBOX ENCLOSURE FOR GAS-FIRED DECORA TIVE TYPE UNVENTED ROOM HEA TERS FOR USE WITH OPTIONAL WOODEN FLUSH MOUNT MANTEL (FF) AND OPTIONAL WOODEN SURROUND (WS) (UNIVERSAL BOX) FOR USE ONLY WITH A LISTED GAS- FIRED UNVE ...

  • New Buck Corporation 42ZCBB - page 2

    ...

  • New Buck Corporation 42ZCBB - page 3

    T ABLE OF CONTENTS Safety Information and Warnings ....................................................................................... 3 Installation .................................................................................................................. ......... 5 Firebox and Framing Dimens ions (ZC) (FF) ........................... ...

  • New Buck Corporation 42ZCBB - page 4

    2 ...

  • New Buck Corporation 42ZCBB - page 5

    SAFETY INFORMA TION W ARNINGS IMPOR T ANT : READ THIS OWNER’S MANUAL CAREF ULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, INSTA LL, OPERATE, OR SERVICE THIS APPLIANCE (FIREBOX ENCLOSURE). Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working prop ...

  • New Buck Corporation 42ZCBB - page 6

    W ARNING DO NOT USE A BLOWER IN SER T , HEA T EXCHANGER INSER T , OR OTHER ACCESSO R Y NOT APPROVED FOR USE WITH THIS HEA TER. THIS HEA TER SHALL NOT BE INST ALLED IN A CONFINED SP ACE UNLESS PR OVISIONS ARE MADE FOR ADEQUA TE COMBUSTION AND VENTILA TION AIR. ”See Page 13, for “Producing Adequate Ventilation”. NOTE: THIS IS A VENTLESS FIREBOX ...

  • New Buck Corporation 42ZCBB - page 7

    INST ALLA TION Your New Buck Ventless Firebox Enclosure may be installed in Residentia l or *After-Market Manufactured Mobile Homes. This appliance may be installed in an *After Market Manufactured Mobile Home, where not prohibited by state or local codes. * (After Market: Completion of sale, not for the purpose of resale from the manufacturer). NO ...

  • New Buck Corporation 42ZCBB - page 8

    FIREBOX AND FRAMING DIMENSIONS (ZC) & (FF) NOTE: SEE PAGE 10 IF AN OPTIONAL WOODEN FLUSH M OUNT MANTEL FRONT (FF) IS TO BE USED. Figure 2 GAS LINE 33-1/8" 18-15/16" 35-5/8" 36-5/8" 19 3/8" 8 1/16" 10 1/4" 36-5/8" Figure 2 37-5/16" 37-5/16" 39 3/8" 35 1/2" 20 1/4" 11 1/4" 45 1 ...

  • New Buck Corporation 42ZCBB - page 9

    Figure 3 FIREBOX CLEARANCES The firebox may be placed dire ctly on a combustible floor, against a combustible wall at m arked clearances, or on a raised wooden platform. If the firebox is to b e installed on a raised woo den platform, the platform m ust be a continuous level surf ace. The firebox must be secured in place so it cannot shift position ...

  • New Buck Corporation 42ZCBB - page 10

    FINISHING YOUR FIREBOX There is a wide variety of finishing material available for your firebox from formal wall treatments with m arble and mantels, to rustic wood paneling, stone or brick. IT IS IMPORTANT THAT THE BLACK FACE OF THE FIREBOX NOT BE COVERED WITH ANY TYPE OF COMBUSTIBLE MATE RIAL. Non-combustible facing m aterials such as marble, bri ...

  • New Buck Corporation 42ZCBB - page 11

    MANTEL PROFILES FOR VE NTLESS FIREBOX ENCLOSURE (UNIVERSAL BOX) ZERO CLEARANC E CABINET MUST BE FOLLOWED A 3” 3/4” 3 1/2” 4” B CANOPY STANDOFF COMBUSTIBLE MATERIALS 42ZCBB MANTEL CLEARANCES MANTEL WIDTH MANTEL HEIGHT (“ A ” inches ) (“ B ” inches above firebox op ening) 6.0 14. 0 8.0 14. 0 10.0 14.0 12.0 16.0 FIGURE 5 9 ...

  • New Buck Corporation 42ZCBB - page 12

    D DATE REV. BY INST ALLA TION INSTRUC TIONS FOR MODEL 42ZCBB OPTIONAL WOODEN FLUSH MOUNT MANTEL FR ONT (FF) (KIT#P AKDM42ZCBBFF) “NOTE: Follow the framing instructions on page (s) 6 & 7. With the excep tion of the placement of the 42ZCBB in the framed opening . The 42ZCBB must be placed w ith the front surface of the appliance 1-9/16” out f ...

  • New Buck Corporation 42ZCBB - page 13

    INST ALLA TION I NSTRUCTI ONS FOR MODEL 42ZCBB OPTIONAL WOODEN SURROUND (WS) (KIT# P AKDM42ZCBB) CLEARANCES: 1. Sidewall Clearances: Clearances from the side of the firebox opening to any adjacent combustible wall should not be less than 7". See Figure 4 2. Ceiling Clearances: The ceiling height should not be less than 42" from the top of ...

  • New Buck Corporation 42ZCBB - page 14

    REAR VIEW After assembling the WS you must insert the 42ZCBB. It is best to insert the 42ZCBB from the rear of the WS, this gives you more area to hold the 42ZCBB and reduces the risk of scratching the sur- face of the front area of the ba se (hearth) area. Flush and cen ter the 42ZCBB’s front in the WS. You can attach the 42ZCBB to the WS with ? ...

  • New Buck Corporation 42ZCBB - page 15

    This section is used for residential inst allation or mobile home installation. UNCONFINED SPACE: An unconfined space has a minimum air volume of 50 cubic feet for each 1,000 BTU/Hr (4.8m 3 per Kw) input rating of all appliances in the space (Cubic feet equals L ength x Width x Height of space). Include adjoining rooms only if there are doorless pa ...

  • New Buck Corporation 42ZCBB - page 16

    3. Add the BTU/Hr of all fuel burning appliances in the space. Vent-Free Heater _________________________BTU/Hr. Gas Water Heater* _________________________BTU/Hr. Gas Furnace _________________________BTU/Hr. Vented Gas Heater _________________________BTU/Hr. Gas Fireplace Logs _________________________BTU/Hr. Other Gas Appliance* +________________ ...

  • New Buck Corporation 42ZCBB - page 17

    VENTILA TION AIR VENTILA TION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconf ined space. When venting to an adjoining space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see Options 1 and 2, Figure 6). You can also ...

  • New Buck Corporation 42ZCBB - page 18

    Figure 7 Ventilation Air From Outdoors W ARNING THIS HEATER MUST HAVE FRESH AIR FOR PROPER OPERATION. IF NOT, POOR FUEL COMBUSTION COULD RESULT. READ THE FOLLOWING INSTRUCTIONS TO ENSURE PROPER FRESH AIR FOR THIS AND OTHER FUEL-BURNING APPLIANCES IN YOUR HOME. VENTILA TION AIR FROM OUTDOORS Provide extra fresh air by using ventilation grills or duc ...

  • New Buck Corporation 42ZCBB - page 19

    OPTIONAL BLOWER INST ALLA TION The Model 42ZCBB has an optional MA ZCBB714 blower kit that can be purchased from your dealer. You will need to follow these steps and th e diagram below and the wiring diagram on page 15. NOTE: The receptacle which is provided in the Model 42ZCBB must be wired into your home (residence) in order to have elec tricity ...

  • New Buck Corporation 42ZCBB - page 20

    W ARNING: CHILDRE N AND ADULTS SHOU LD BE ALERTED OF HIGH SURFACE TEMPERATURE AND SHOULD STAT AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE APPLIANCE. W ARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE APPLIANCE. WIRING DIAGRAM (MA ZCBB714) NOT ...

  • New Buck Corporation 42ZCBB - page 21

    REPLACEMENT P AR TS 1. PULL SCREEN (2) PER UNIT 2. SCREEN RODS (2) PER UNIT 3. REAR REFRACT OR Y AND SIDE REFRACT OR Y 2 PIECES PER UNIT 6. CANOPY 7. DOOR KIT (P AR T# MAZCBBDOORS) P AR TS MA Y BE OBT AINED THROUGH YOUR LOCAL NBC DEALER. IN ABSENCE OF A DEALER, PLEASE CONT ACT NEW BUCK CORPORA TION A T P .O. BOX 69, 8000 HWY 226 SOUTH, SPRUCE PINE ...

  • New Buck Corporation 42ZCBB - page 22

    NEW BUCK CORPORA TION We reserve the right to amend th ese specifications at any tim e without notice. The only warranty applicable is our standard wr itten warranty. We offer no other warranty, expressed or implied. LIMITED W ARRANTY VENTLESS FIREBOX ENCLOSURE New Buck warrants this product to be free from defects in materials and com ponents for ...

Fabricant New Buck Corporation Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilNew Buck Corporation 42ZCBB peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques New Buck Corporation
- manuels d’utilisations 42ZCBB
- fiches produit New Buck Corporation
- dépliants
- ou étiquettes-énergie New Buck Corporation 42ZCBB
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation New Buck Corporation 42ZCBB.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation New Buck Corporation 42ZCBB, manuels d’entretien, brefs manuels ou manuels de l’utilisateur New Buck Corporation 42ZCBB. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit New Buck Corporation 42ZCBB.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil New Buck Corporation 42ZCBB, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser New Buck Corporation 42ZCBB par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs New Buck Corporation 42ZCBB.

Le manuel d’utilisation complet New Buck Corporation, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel New Buck Corporation 42ZCBB - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières New Buck Corporation 42ZCBB, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNew Buck Corporation 42ZCBB qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil New Buck Corporation 42ZCBB - qui devraient nous aider dans les premières étapes lors de l'utilisation New Buck Corporation 42ZCBB
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de New Buck Corporation 42ZCBB
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service New Buck Corporation 42ZCBB dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de New Buck Corporation 42ZCBB?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec New Buck Corporation 42ZCBB, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec New Buck Corporation 42ZCBB il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)