    New Buck Corporation Revised: November 2004 P.O. Box 69 8000 Hwy. 226 Sou th Spruce Pine, NC 28777 BUCK ST OVE MODEL 42ZCBB VENTLESS FIREBOX ENCLOSURE FOR GAS-FIRED DECORA TIVE TYPE UNVENTED ROOM HEA TERS FOR USE WITH OPTIONAL WOODEN FLUSH MOUNT MANTEL (FF) AND OPTIONAL WOODEN SURROUND (WS) (UNIVERSAL BOX) FOR USE ONLY WITH A LISTED GAS- FIRED UNVE ...

  • New Buck Corporation 42ZCBB - page 2

    ...

  • New Buck Corporation 42ZCBB - page 3

    T ABLE OF CONTENTS Safety Information and Warnings ....................................................................................... 3 Installation .................................................................................................................. ......... 5 Firebox and Framing Dimens ions (ZC) (FF) ........................... ...

  • New Buck Corporation 42ZCBB - page 4

    2 ...

  • New Buck Corporation 42ZCBB - page 5

    SAFETY INFORMA TION W ARNINGS IMPOR T ANT : READ THIS OWNER’S MANUAL CAREF ULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, INSTA LL, OPERATE, OR SERVICE THIS APPLIANCE (FIREBOX ENCLOSURE). Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working prop ...

  • New Buck Corporation 42ZCBB - page 6

    W ARNING DO NOT USE A BLOWER IN SER T , HEA T EXCHANGER INSER T , OR OTHER ACCESSO R Y NOT APPROVED FOR USE WITH THIS HEA TER. THIS HEA TER SHALL NOT BE INST ALLED IN A CONFINED SP ACE UNLESS PR OVISIONS ARE MADE FOR ADEQUA TE COMBUSTION AND VENTILA TION AIR. ”See Page 13, for “Producing Adequate Ventilation”. NOTE: THIS IS A VENTLESS FIREBOX ...

  • New Buck Corporation 42ZCBB - page 7

    INST ALLA TION Your New Buck Ventless Firebox Enclosure may be installed in Residentia l or *After-Market Manufactured Mobile Homes. This appliance may be installed in an *After Market Manufactured Mobile Home, where not prohibited by state or local codes. * (After Market: Completion of sale, not for the purpose of resale from the manufacturer). NO ...

  • New Buck Corporation 42ZCBB - page 8

    FIREBOX AND FRAMING DIMENSIONS (ZC) & (FF) NOTE: SEE PAGE 10 IF AN OPTIONAL WOODEN FLUSH M OUNT MANTEL FRONT (FF) IS TO BE USED. Figure 2 GAS LINE 33-1/8" 18-15/16" 35-5/8" 36-5/8" 19 3/8" 8 1/16" 10 1/4" 36-5/8" Figure 2 37-5/16" 37-5/16" 39 3/8" 35 1/2" 20 1/4" 11 1/4" 45 1 ...

  • New Buck Corporation 42ZCBB - page 9

    Figure 3 FIREBOX CLEARANCES The firebox may be placed dire ctly on a combustible floor, against a combustible wall at m arked clearances, or on a raised wooden platform. If the firebox is to b e installed on a raised woo den platform, the platform m ust be a continuous level surf ace. The firebox must be secured in place so it cannot shift position ...

  • New Buck Corporation 42ZCBB - page 10

    FINISHING YOUR FIREBOX There is a wide variety of finishing material available for your firebox from formal wall treatments with m arble and mantels, to rustic wood paneling, stone or brick. IT IS IMPORTANT THAT THE BLACK FACE OF THE FIREBOX NOT BE COVERED WITH ANY TYPE OF COMBUSTIBLE MATE RIAL. Non-combustible facing m aterials such as marble, bri ...

  • New Buck Corporation 42ZCBB - page 11

    MANTEL PROFILES FOR VE NTLESS FIREBOX ENCLOSURE (UNIVERSAL BOX) ZERO CLEARANC E CABINET MUST BE FOLLOWED A 3” 3/4” 3 1/2” 4” B CANOPY STANDOFF COMBUSTIBLE MATERIALS 42ZCBB MANTEL CLEARANCES MANTEL WIDTH MANTEL HEIGHT (“ A ” inches ) (“ B ” inches above firebox op ening) 6.0 14. 0 8.0 14. 0 10.0 14.0 12.0 16.0 FIGURE 5 9 ...

  • New Buck Corporation 42ZCBB - page 12

    D DATE REV. BY INST ALLA TION INSTRUC TIONS FOR MODEL 42ZCBB OPTIONAL WOODEN FLUSH MOUNT MANTEL FR ONT (FF) (KIT#P AKDM42ZCBBFF) “NOTE: Follow the framing instructions on page (s) 6 & 7. With the excep tion of the placement of the 42ZCBB in the framed opening . The 42ZCBB must be placed w ith the front surface of the appliance 1-9/16” out f ...

  • New Buck Corporation 42ZCBB - page 13

    INST ALLA TION I NSTRUCTI ONS FOR MODEL 42ZCBB OPTIONAL WOODEN SURROUND (WS) (KIT# P AKDM42ZCBB) CLEARANCES: 1. Sidewall Clearances: Clearances from the side of the firebox opening to any adjacent combustible wall should not be less than 7". See Figure 4 2. Ceiling Clearances: The ceiling height should not be less than 42" from the top of ...

  • New Buck Corporation 42ZCBB - page 14

    REAR VIEW After assembling the WS you must insert the 42ZCBB. It is best to insert the 42ZCBB from the rear of the WS, this gives you more area to hold the 42ZCBB and reduces the risk of scratching the sur- face of the front area of the ba se (hearth) area. Flush and cen ter the 42ZCBB’s front in the WS. You can attach the 42ZCBB to the WS with ? ...

  • New Buck Corporation 42ZCBB - page 15

    This section is used for residential inst allation or mobile home installation. UNCONFINED SPACE: An unconfined space has a minimum air volume of 50 cubic feet for each 1,000 BTU/Hr (4.8m 3 per Kw) input rating of all appliances in the space (Cubic feet equals L ength x Width x Height of space). Include adjoining rooms only if there are doorless pa ...

  • New Buck Corporation 42ZCBB - page 16

    3. Add the BTU/Hr of all fuel burning appliances in the space. Vent-Free Heater _________________________BTU/Hr. Gas Water Heater* _________________________BTU/Hr. Gas Furnace _________________________BTU/Hr. Vented Gas Heater _________________________BTU/Hr. Gas Fireplace Logs _________________________BTU/Hr. Other Gas Appliance* +________________ ...

  • New Buck Corporation 42ZCBB - page 17

    VENTILA TION AIR VENTILA TION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconf ined space. When venting to an adjoining space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see Options 1 and 2, Figure 6). You can also ...

  • New Buck Corporation 42ZCBB - page 18

    Figure 7 Ventilation Air From Outdoors W ARNING THIS HEATER MUST HAVE FRESH AIR FOR PROPER OPERATION. IF NOT, POOR FUEL COMBUSTION COULD RESULT. READ THE FOLLOWING INSTRUCTIONS TO ENSURE PROPER FRESH AIR FOR THIS AND OTHER FUEL-BURNING APPLIANCES IN YOUR HOME. VENTILA TION AIR FROM OUTDOORS Provide extra fresh air by using ventilation grills or duc ...

  • New Buck Corporation 42ZCBB - page 19

    OPTIONAL BLOWER INST ALLA TION The Model 42ZCBB has an optional MA ZCBB714 blower kit that can be purchased from your dealer. You will need to follow these steps and th e diagram below and the wiring diagram on page 15. NOTE: The receptacle which is provided in the Model 42ZCBB must be wired into your home (residence) in order to have elec tricity ...

  • New Buck Corporation 42ZCBB - page 20

    W ARNING: CHILDRE N AND ADULTS SHOU LD BE ALERTED OF HIGH SURFACE TEMPERATURE AND SHOULD STAT AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE APPLIANCE. W ARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE APPLIANCE. WIRING DIAGRAM (MA ZCBB714) NOT ...

  • New Buck Corporation 42ZCBB - page 21

    REPLACEMENT P AR TS 1. PULL SCREEN (2) PER UNIT 2. SCREEN RODS (2) PER UNIT 3. REAR REFRACT OR Y AND SIDE REFRACT OR Y 2 PIECES PER UNIT 6. CANOPY 7. DOOR KIT (P AR T# MAZCBBDOORS) P AR TS MA Y BE OBT AINED THROUGH YOUR LOCAL NBC DEALER. IN ABSENCE OF A DEALER, PLEASE CONT ACT NEW BUCK CORPORA TION A T P .O. BOX 69, 8000 HWY 226 SOUTH, SPRUCE PINE ...

  • New Buck Corporation 42ZCBB - page 22

    NEW BUCK CORPORA TION We reserve the right to amend th ese specifications at any tim e without notice. The only warranty applicable is our standard wr itten warranty. We offer no other warranty, expressed or implied. LIMITED W ARRANTY VENTLESS FIREBOX ENCLOSURE New Buck warrants this product to be free from defects in materials and com ponents for ...

メーカー New Buck Corporation カテゴリー Indoor Fireplace

New Buck Corporation 42ZCBBのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 42ZCBBの取扱説明書
- New Buck Corporationの製品カード
- パンフレット
- またはNew Buck Corporation 42ZCBBの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、New Buck Corporation 42ZCBBの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、New Buck Corporation 42ZCBBの取り付け説明書、サービスマニュアル、簡易説明書、またはNew Buck Corporation 42ZCBBのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、New Buck Corporation 42ZCBBの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

New Buck Corporation 42ZCBBデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNew Buck Corporation 42ZCBBを使用するのを助ける技術的文書のことです。説明書は通常、全てのNew Buck Corporation 42ZCBBユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

New Buck Corporationの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. New Buck Corporation 42ZCBBの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNew Buck Corporation 42ZCBBの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。New Buck Corporation 42ZCBBに関してこのドキュメントで見つけることができる全てのヒントの目次
3. New Buck Corporation 42ZCBBデバイスの基本機能を使うにあたってのヒント。 New Buck Corporation 42ZCBBのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。New Buck Corporation 42ZCBBに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNew Buck Corporation 42ZCBBのメーカー/サービスへの連絡先に関する情報。

New Buck Corporation 42ZCBBについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNew Buck Corporation 42ZCBBの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNew Buck Corporation 42ZCBBで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)