    This document describes the performance and features of the following products: • Agilent 8753ES S-paramet er vector netw ork analyzer • Agilent 8753ES Option 011 vector network analyzer without test set • Agilent 8753ET T ransmission/ref lection vector netw ork analyzer F or more information about these analyzers, please see the follo wing d ...

  • Agilent Technologies 8753ES - page 2

    3 4 10 21 21 22 24 T able of Contents Definitions and T est Conditions System Performance Summaries Specifications and Characteristics Measurement Throughput Summary Options T est Set Specifications for Option 01 1 Accessories ...

  • Agilent Technologies 8753ES - page 3

    3 Specif ications describe t he instrument’s war ranted performance af ter a half-hour war m-up and ov er the temperature range of 25° ± 5° C, unless other- wise stat ed. Specifications for frequencies abo ve 3 GHz do not apply to instruments wit h Option 075 (75-ohm impedance). Supplemental charact eristics are typical but non- warranted per ...

  • Agilent Technologies 8753ES - page 4

    4 Agilent 8753ES (50-ohm systems) 7-mm test ports Configuration Network analyzer 8753ES Standard and Option 006 Calibration kit 85031B T est-port cables 11857D System dynamic range 30 kHz to 50 kHz 70 dB 1 50 kHz to 300 kHz 90 dB 1 300 kHz to 16 MHz 100 dB 16 MHz to 3 GHz 110 dB Option 014 108 dB 3 GHz to 6 GHz 105 dB Option 014 103 dB Measurement ...

  • Agilent Technologies 8753ES - page 5

    5 Agilent 8753ES (50-ohm systems) T ype-N test ports Configuration Network analyzer 8753ES Standard and Option 006 Calibration kit 85032B T est-port cables 11857D System dynamic range 30 kHz to 50 kHz 70 dB 1 50 kHz to 300 kHz 90 dB 1 300 kHz to 16 MHz 100 dB 16 MHz to 3 GHz 110 dB Option 014 108 dB 3 GHz to 6 GHz 105 dB Option 014 103 dB Measureme ...

  • Agilent Technologies 8753ES - page 6

    6 Agilent 8753ES (50-ohm systems) 3.5-mm test ports Configuration Network analyzer 8753ES Standard and Option 006 Calibration kit 85033D T est-port cables 11857D System dynamic range 30 kHz to 50 kHz 70 dB 1 50 kHz to 300 kHz 90 dB 1 300 kHz to 16 MHz 100 dB 16 MHz to 3 GHz 110 dB Option 014 108 dB 3 GHz to 6 GHz 105 dB Option 014 103 dB Measuremen ...

  • Agilent Technologies 8753ES - page 7

    Agilent 8753ES (75-Ohm Systems) T ype-N test ports Configuration Network analyzer 8753ES Option 075 Calibration kit 85036B T est-port cables 11857B System Dynamic Range 30 kHz to 50 kHz 68 dB 1 50 kHz to 300 kHz 90 dB 1 300 kHz to 16 MHz 96 dB 16 MHz to 3 GHz 106 dB Measurement Port Characteristics Frequency Range Corrected 30 kHz–300 kHz 2 300 k ...

  • Agilent Technologies 8753ES - page 8

    8 Agilent 8753ES (75-ohm systems) T ype-F test ports Configuration Network analyzer 8753E Option 075 Calibration kit 85039B T est-port cables 11857B System dynamic range 30 kHz to 50 kHz 68 dB 1 50 kHz to 300 kHz 90 dB 1 300 kHz to 16 MHz 96 dB 16 MHz to 3 GHz 106 dB Measurement Port Characteristics Data is shown for a T ype-F female reflection por ...

  • Agilent Technologies 8753ES - page 9

    9 1. One-port or enhanced-response calibration. 2. Enhanced-response or response-only calibration. 3. 2 dB less with Option 004. 4. Option 004 may degrade uncorrected source match as much as 2 dB. T ransmission uncertainty (enhanced-response calibration) T ransmission uncertainty (response calibration) Reflection uncertainty (one-port calibration) ...

  • Agilent Technologies 8753ES - page 10

    10 T est-Port Output Characteristics 7 Frequency characteristics Range 30 kHz to 3 GHz Option 006 30 kHz to 6 GHz Resolution 1 Hz Stability 9 ±7.5 ppm (0° to 55° C) ±3 ppm/year Option 1D5 ±0.05 ppm (0° to 55° C), ±0.5 ppm/year Accuracy ±10 ppm at 25° ±5° C Power range 2 -85 to +10 dBm Option 075/014 -85 to +8 dBm Power sweep range 25 dB ...

  • Agilent Technologies 8753ES - page 11

    11 External source mode 1 (CW time sweep only) Frequency range 300 kHz to 6 GHz R-channel input requirements (typical) Power level 0 to -25 dBm Spectral purity Maximum <-30 dBc spurious input Residual FM <20 kHz T ypical settling time 500 ms (automatic) 50 ms (manual) Frequency readout accuracy 0.1% (automatic) Input frequency accuracy requir ...

  • Agilent Technologies 8753ES - page 12

    12 T est Port Output Characteristics Frequency characteristics Range 300 kHz to 3 GHz Option 006 30 kHz to 6 GHz Resolution 1 Hz Stability typically ±7.5 ppm 0° to 55° C typically ±3 ppm/year Option 1D5 typically ±0.05 ppm 0° to 55° C typically ±0.5 ppm/year Accuracy ±10 ppm at 25° ± 5° C Power range -5 to +20 dBm Option 006 -5 to +18 d ...

  • Agilent Technologies 8753ES - page 13

    13 Frequency offset mode 3 Frequency range 300 kHz to 3 GHz Option 006 300 kHz to 6 GHz R-channel input requirements Power level 300 kHz to 3 GHz 0 to -35 dBm 3 GHz to 6 GHz 0 to -30 dBm LO spectral purity Maximum spurious input <-25 dBc Residual FM <20 kHz LO frequency accuracy ±1 MHz at nominal frequency External source mode 4 (CW time swe ...

  • Agilent Technologies 8753ES - page 14

    14 T est-Port Output Characteristics Frequency characteristics Range 300 kHz to 3 GHz Option 006 300 kHz to 6 GHz Resolution 1 Hz Stability 4 ±7.5 ppm (0° to 55° C) ±3 ppm/year Option 1D5 ±0.05 ppm (0° to 55° C) ±0.5 ppm/year Accuracy ±10 ppm at 25° ±5° C Power range -20 to +5 dBm -85 to +10 dBm (with Option 004) Resolution 0.01 dB Leve ...

  • Agilent Technologies 8753ES - page 15

    15 External source mode 1 (CW time sweep only) Frequency range 300 kHz to 6 GHz R-channel input requirements 2 Power level 0 to -25 dBm Spectral purity Maximum spurious input <-30 dBc Residual FM <20 kHz T ypical settling time 500 ms (automatic) 50 ms (manual) Frequency readout accuracy 2 0.1% (automatic) Input frequency accuracy requirement ...

  • Agilent Technologies 8753ES - page 16

    Measurement Number of display channels F our display channels a vailable. Number of measurement channels T w o primary and two auxiliary measurement channels available. Measurement parameters 8753ET: Ref lection, transmission, A, B, R, A/R, B/R, A/B. Conversion to im pedance or admitt ance. 8753ES: S11, S21, S12, S22, A, B, R, A/R, B/R, A/B. Conver ...

  • Agilent Technologies 8753ES - page 17

    17 Sweep trigger Set to either continuous, sing le, g roup sw eep, or external trigger . Set external trigger t o take a com- plete sweep or to measure individual points in a frequency , pow er or list sw eep. Power Set source po w er from -20 to +5 dBm f or the 8753ET 1 or from -85 to +10 dBm f or the 8753ES 2 . P o w er slope can be set in dBm/GH ...

  • Agilent Technologies 8753ES - page 18

    18 T race Functions Display data Displa y current measurement data, memor y dat a, or current measurement wit h measurement and memor y dat a simultaneously. T race math V ect or division or subtraction of cur rent linear measurement values and memor y dat a. Display annotations Star t/st op, center/span, or CW frequency , source lev el, scale/div ...

  • Agilent Technologies 8753ES - page 19

    19 Frequency offset on/off Sets the RF source to be swept at a fixed offset frequency abo ve the receiver as required in a sw ept RF/IF , fixed LO, mix er t est. Service menu Select the desired service test, service diagnostic, service or verification mode. T est Sequences Description Creat e, edit, sav e, or recall a series of front-panel k ey- s ...

  • Agilent Technologies 8753ES - page 20

    20 Front Panel Connectors 8753ES test ports (without Option 011) Connector type 7 mm, precision Impedance 50 ohms (nominal) 8753ES Option 011 test ports Connector type T ype-N female Impedance 50 ohms (nominal) 8753ES Option 075 test ports Connector type T ype-N female Impedance 75 ohms (nominal) 8753ET test ports Connector type T ype-N female Impe ...

  • Agilent Technologies 8753ES - page 21

    21 General Conditions RFI and EMI susceptibility: defined by VDE 0730, CISPR Publication 11, and FCC Class B Standards. ESD (electrostatic discharge): must be eliminated by use of static-safe w ork procedures and an anti- static bench mat. The f lexible r ubber ke ypad pro- tects ke y cont acts from dust, but the environment should be as dust-free ...

  • Agilent Technologies 8753ES - page 22

    22 Agilent 85046A/B S-Parameter T est Sets The 85046A/B S-parameter test sets provide the capability to measure ref lection and transmission characteristics (including S-parameters) of two- port devices in either direction wit h a sing le connection. The test sets are controlled from the 8753ES Option 011 and include a programmable step attenuat or ...

  • Agilent Technologies 8753ES - page 23

    23 Agilent 85047A S-Parameter T est Set The 85047A S-parameter test set provides the capability to simult aneously measure the ref lec- tion and transmission characteristics of two-port devices in either direction with a sing le connec- tion. This test set includes a frequency doubler that can be swit ched in by an 8753B/C Option 006 to measure 3 M ...

  • Agilent Technologies 8753ES - page 24

    24 Calibration Kits V ect or accuracy enhancement procedures require that t he systematic errors of the measurement sys- t em be characterized b y measuring kno wn devices (standards) on the syst em ov er the frequency range of interest. Return loss specif ications or typical values are pro vided where a vailable for the ter minations and adapters. ...

  • Agilent Technologies 8753ES - page 25

    25 Agilent 85038 Family of Calibration Kits The 85038A calibration kit contains open circuits, short circuits, and ter minations with bot h male and female 7-16 connectors. More economical v er- sions of this kit are available: the 85038M contains only male de vices, and the 85038F provides onl y female de vices (see f ollo wing t able). Each kit c ...

  • Agilent Technologies 8753ES - page 26

    26 V erification Kits Measuring kno wn devices other than t he st andards used in calibration is an easy way to v erify the proper operation of an 8753ES measurement sys- t em. Agilent of fers v erification kits which include devices, with data, for verifying the error -correct ed measurements of an 8753ES and 50-ohm test sets. 85029B 7-mm verifica ...

  • Agilent Technologies 8753ES - page 27

    27 Connectors 50-ohm type-N (f) to 75-ohm type-N (m) standard Option 004, 50-ohm type-N (m) to 75-ohm type-N (f) Dimensions 14-mm D x 70-mm L (0.56 in x 2.75 in) W eight Net 0.1 kg (0.316 lb) 50-Ohm Accessory Kits The 11853A 50-ohm type-N and the 11854A 50-ohm BNC accessory kits provide the RF com ponents generally required when using either the 85 ...

  • Agilent Technologies 8753ES - page 28

    Agilent 8347A RF Amplifier The 8347A RF amplifier delivers increased po wer acr oss a 300 kHz to 3 GHz frequency range. The 8347A pro vides lev eled output po w er without using an exter nal coupler and detect or , since these par ts are built-in. The exter nal ALC can be directly connected to the ext ernal AM input on the 8753ET/ES. This capabilit ...

Fabricant Agilent Technologies Catégorie Network Router

Les documents que nous recevons du fabricant de l'appareilAgilent Technologies 8753ES peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Agilent Technologies
- manuels d’utilisations 8753ES
- fiches produit Agilent Technologies
- dépliants
- ou étiquettes-énergie Agilent Technologies 8753ES
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Agilent Technologies 8753ES.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Agilent Technologies 8753ES, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Agilent Technologies 8753ES. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Agilent Technologies 8753ES.

Manuel d’utilisation complet de l’appareil Agilent Technologies 8753ES, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Agilent Technologies 8753ES par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Agilent Technologies 8753ES.

Le manuel d’utilisation complet Agilent Technologies, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Agilent Technologies 8753ES - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Agilent Technologies 8753ES, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAgilent Technologies 8753ES qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Agilent Technologies 8753ES - qui devraient nous aider dans les premières étapes lors de l'utilisation Agilent Technologies 8753ES
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Agilent Technologies 8753ES
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Agilent Technologies 8753ES dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Agilent Technologies 8753ES?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Agilent Technologies 8753ES, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Agilent Technologies 8753ES il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)