Manuel d’utilisation Maxim DS5001FP

26 pages 0.56 mb
Télécharger

Aller à la page of 26

Summary
  • Maxim DS5001FP - page 1

    1 of 26 052302 Note: Some rev isions of this device may incorporate deviations fro m published specifications known as errata. Multiple revisi ons of any device m ay be simulta neously av ailable through various sales chann els. For inf ormation abou t device errata, click here: http://www.maxim-ic.com/errata . FEATURES § 8051-compatible micropro ...

  • Maxim DS5001FP - page 2

    DS5001FP 2 of 26 DESCRIPTION The DS5001FP 128k soft microprocessor chip is an 8051-compatible microp ro cessor based on NV RAM technology and designed for s ystems that need la rge quantities of nonvolatile memory. It provides full compatibility with the 8051 instructi on set, timers, serial port, and pa rallel I/O ports. By using NV RAM instead of ...

  • Maxim DS5001FP - page 3

    DS5001FP 3 of 26 Figure 1. BLOCK DI AGRA M ...

  • Maxim DS5001FP - page 4

    DS5001FP 4 of 26 PIN DESCRIPTION 80-PIN MQ FP 44-PIN MQ FP SIGNAL DESCR IPTION 11, 9, 7, 5, 1, 79, 77, 75 31 (P0.5) P0.0–P 0.7 General-Purpose I/O Port 0. This port i s open- drain and cann ot drive a log ic 1. It requi res external pullups. Port 0 is also the m ultiplexed expanded address/ data bus. When used in this mode, it doe s not require p ...

  • Maxim DS5001FP - page 5

    DS5001FP 5 of 26 33, 35, 37 9 and A15 res pectively. 71, 69, 67, 65, 61, 59, 57, 55 28, 26, 24, 23, 21, 20, 19, 18 BD7–0 Byte-Wide Data-Bus Bits 7–0 . This 8-bit, bidirectional bus is combined with the nonmultiplex ed address bu s (BA14–0) to access NV SRA M. Decoding is perf ormed on CE1 and CE2 . Read/write access is controlled by R/ W . BD ...

  • Maxim DS5001FP - page 6

    DS5001FP 6 of 26 INSTRUCTION SET The DS5001FP executes an instruction set that is obj ect code-comp atible with the industry standard 8051 microcontro ller. As a result, software dev elopment pac kages such as assembler s and compiler s that have been written for the 8051 are compatible with the DS 5001FP. A complete description of the instruction ...

  • Maxim DS5001FP - page 7

    DS5001FP 7 of 26 Figu re 3. ME MORY MA P IN PA RTITIONA BLE MODE (PM = 0) Note: Partitionable mode is not supported when MSEL pin = 0 (128kB mode). ...

  • Maxim DS5001FP - page 8

    DS5001FP 8 of 26 Figure 4. MEM ORY MAP WITH PES = 1 ...

  • Maxim DS5001FP - page 9

    DS5001FP 9 of 26 Figure 5 illustrates a typical memo ry connection for a s ystem using a 128kB SRAM. Note that in this configuration, both program and data are stored in a common RAM chip Figure 6 shows a similar s ystem with using two 32kB SRAMs. The byte-wide addre ss bus connects to the SRAM address lines. The bidirectional byte-wide data bus co ...

  • Maxim DS5001FP - page 10

    DS5001FP 10 of 26 Figure 6. DS5001FP CONNECTION TO 64k x 8 SRAM POWER M A N AGEMENT The DS5001FP monitors V CC to provide power-fail reset, earl y war ning power-f ail interrupt, and switc h over to lithium backup. It uses an internal band gap re ference in dete rmining the switch points. These are called V PF W , V CCMIN , and V LI , respec tively ...

  • Maxim DS5001FP - page 11

    DS5001FP 11 of 26 ABSOLUTE MA XIM UM RA TINGS* Voltage Range on An y Pin Re lative to Ground -0.3V to (V CC + 0.5V) Voltage Range on V CC Related to Ground -0.3 ° C to 6.0 ° C Operatin g Temperature R ange -40 ° C to +85 ° C Storage Temper ature Range 1 -55 ° C to +125 ° C Soldering Temperature See IPC/JEDEC J-STD-020A * This is a stress rati ...

  • Maxim DS5001FP - page 12

    DS5001FP 12 of 26 DC CHARACTERISTICS (continued) (T A = 0°C to +70°C; V CC = 5V ±10%) PARAM ETER SYMBOL MIN TYP MAX UNITS N OTES Input L eakage Current 0.45 < V IN < V CC (Port 0, MSEL) I IL +10 µA RST Pulldown Resistor (0°C to +70°C) R RE 40 150 k W RST Pulldown Resistor (-40°C to +85°C) R RE 30 180 k W 10 VRST Pullup Resistor R VR 4 ...

  • Maxim DS5001FP - page 13

    DS5001FP 13 of 26 AC C H AR AC T E R I S T I C S EXPANDED BUS MODE TIMING SPECIFICA TIONS (T A = 0°C to +70°C; V CC = 5V ±10%) # PARA METER SYMBOL MI N MAX UNITS 1 Oscillator Frequency 1/ t CLK 1.0 16 MHz 2 ALE Pulse Width t ALPW 2t CLK - 40 ns 3 Address Valid to ALE Low t AV AL L t CLK - 40 ns 4 Address Hold After A LE Low t AVA AV t CLK - 35 n ...

  • Maxim DS5001FP - page 14

    DS5001FP 14 of 26 EXPANDED PROGRAM-MEMORY RE AD CYCLE EXPANDED DATA-M EMORY RE AD CYCLE ...

  • Maxim DS5001FP - page 15

    DS5001FP 15 of 26 EXPANDED DATA-M EMORY WRI TE CYCLE ...

  • Maxim DS5001FP - page 16

    DS5001FP 16 of 26 AC C H AR AC T E R I S T I C S (continued) EXTERNAL CLOCK DRIVE (T A = 0°C to +70°C; V CC = 5V ±10%) # PARA METER SYMBOL MIN MAX U NITS 28 External Clock-High Time at 12MHz at 16MHz t CLK HPW 20 15 ns 29 External Clock-Low Time at 12MHz at 16MHz t CLKL PW 20 15 ns 30 External Clock-Rise Time at 12MHz at 16MHz t CLK R 20 15 ns 3 ...

  • Maxim DS5001FP - page 17

    DS5001FP 17 of 26 AC C H AR AC T E R I S T I C S (continued) POWER CYCLE TIME (T A = 0 °C to +70 °C; V CC = 5V ±10% ) # PARA METER SYMBOL MIN MAX U NITS 32 Slew Rate from V CCMI N to V LI t F 130 µs 33 Cry stal Startup Time t CSU (Note 9) 34 Power-On Reset Dela y t POR 21,504 t CLK POWER CYCLE TIMING ...

  • Maxim DS5001FP - page 18

    DS5001FP 18 of 26 AC C H AR AC T E R I S T I C S (continued) SERIAL PORT TIMING, MODE 0 (T A = 0°C to +70°C; V CC = 5V ±10%) # P ARAMETER SYMBOL MIN MAX UNITS 35 Serial-Port Clock-Cycle Time t SPCLK 12t CLK µs 36 Output-Data Setup to Rising-Clock Edge t DOCH 10t CLK - 133 ns 37 Output-Data Hold After Rising-Clock Edge t CHDO 2t CLK - 117 ns 38 ...

  • Maxim DS5001FP - page 19

    DS5001FP 19 of 26 AC C H AR AC T E R I S T I C S (continued) BYTE-WIDE A DDRESS/DATA BUS TIMING (T A = 0°C to +70°C; V CC = 5V ±10%) # PARA METER SYMBOL MIN MA X UNITS 40 Delay to Byte- Wide Address Valid from CE1 , CE2 , or CE1N Low During Op Code Fetch t CE1L PA 30 ns 41 Pulse Width of CE 1-4, PE 1-4 or CE1N t CEPW 4t CLK - 35 ns 42 Byte-Wide ...

  • Maxim DS5001FP - page 20

    DS5001FP 20 of 26 BYTE-WIDE BUS TIMING RPC AC CHARACTERISTI CS, DBB READ (T A = 0°C to + 70°C; V CC = 5V ±10%) # PARA METER SYMBOL MIN MAX U NITS 54 CS , A 0 Setup to RD t AR 0n s 55 CS , A 0 Hold After RD t RA 0n s 56 RD Pulse Width t RR 160 ns 57 CS , A 0 to Data-Out Delay t AD 130 ns 58 RD to Data-Out Delay t RD 0 130 ns 59 RD to Data-Floa t ...

  • Maxim DS5001FP - page 21

    DS5001FP 21 of 26 RPC AC CHARACTERISTI CS, DBB WRITE (T A = 0°C to +70°C; V CC = 5V ±10%) # PARA METER SYMBOL MIN MAX U NITS 60 CS , A 0 Setup to WR t AW 0n s 61A CS , Hold After WR t WA 0n s 61B A 0 , Hold After WR t WA 20 ns 62 WR Pulse Width t WW 160 ns 63 Data Setup to WR t DW 130 ns 64 Data Hold After WR t WD 20 ns AC CHARA CTERISTICS, D MA ...

  • Maxim DS5001FP - page 22

    DS5001FP 22 of 26 RPC TIMING MO DE ...

  • Maxim DS5001FP - page 23

    DS5001FP 23 of 26 NOTES: All parameters appl y to both co mmercial and indus trial temperature operation unless otherwise noted. 1) All voltages are referenced to ground. 2) Maximum operating I CC is measured with all output pins disconnected; XTAL1 driv en with t CL KR , t CLKF = 10ns, V IL = 0.5V; XTAL2 disconnected; RST = PORT0 = V CC , MSEL = V ...

  • Maxim DS5001FP - page 24

    DS5001FP 24 of 26 80-PIN MQFP MM DIM MIN M A X A -3 . 4 0 A1 0.25 - A2 2.55 2.87 B 0.30 0.50 C 0.13 0.23 D 23.70 24.10 D1 19.90 20.10 E 17.70 18.10 E1 13.90 14.10 e 0.80 BSC L 0.65 0.95 56-G4005- 001 ...

  • Maxim DS5001FP - page 25

    DS5001FP 25 of 26 44-PIN MQFP ...

  • Maxim DS5001FP - page 26

    DS5001FP 26 of 26 REVISION HISTORY The following represent the key differenc es between 112795 and 073096 version of the DS5001 FP data sheet. Please r eview this summar y carefull y . 1) Chang e V CC02 specification from V LI - 0.5 to V LI - 0.65 (PCN F62501). 2) Update mechanical specifications. The following represent the key differenc es betwee ...

Fabricant Maxim Catégorie Computer Hardware

Les documents que nous recevons du fabricant de l'appareilMaxim DS5001FP peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Maxim
- manuels d’utilisations DS5001FP
- fiches produit Maxim
- dépliants
- ou étiquettes-énergie Maxim DS5001FP
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Maxim DS5001FP.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Maxim DS5001FP, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Maxim DS5001FP. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Maxim DS5001FP.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Maxim DS5001FP, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Maxim DS5001FP par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Maxim DS5001FP.

Le manuel d’utilisation complet Maxim, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Maxim DS5001FP - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Maxim DS5001FP, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lMaxim DS5001FP qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Maxim DS5001FP - qui devraient nous aider dans les premières étapes lors de l'utilisation Maxim DS5001FP
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Maxim DS5001FP
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Maxim DS5001FP dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Maxim DS5001FP?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Maxim DS5001FP, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Maxim DS5001FP il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)