Manuel d’utilisation Linak MEDLINE MJB

24 pages 0.23 mb
Télécharger

Aller à la page of 24

Summary
  • Linak MEDLINE MJB - page 1

    T o learn more about LINAK please visit: WWW .LINAK.COM MJB - Gateway USER MANUAL ...

  • Linak MEDLINE MJB - page 2

    2 ...

  • Linak MEDLINE MJB - page 3

    Contents Preface .............................................................................................................................. .................................... 4 Important information .............................................................................................................................. .......... 5 Safet ...

  • Linak MEDLINE MJB - page 4

    Pr eface We ar e delighted that you have chosen a product fr om LINAK ® . LINAK systems are high-tech pr oducts based on many years of experience in the manufacture and development of actuators, electric contr ol boxes, controls and chargers. This User Manual will tell you how to install, use and maintain your LINAK equipment. We ar e sure that yo ...

  • Linak MEDLINE MJB - page 5

    5 Safety instructions Safe use of the system is possible only when the operating instructions are r ead completely and the instructions contained are strictly observed. Failure to comply with instructions marked with the”NOTE” symbol may r esult in serious damage to the system or one of its components. Persons who do not have the necessary expe ...

  • Linak MEDLINE MJB - page 6

    Residual risk Some of the products contains softwar e based components. LINAK has made various possible efforts to assur e that the software is fr ee of errors and that the software has been developed accor ding to the rules of IEC 60601-1-4 (software in Medical pr oducts). That involves Risk Analysis which shows a small residual risk for unwanted/ ...

  • Linak MEDLINE MJB - page 7

    7 Before installation, r e-installation, or troubleshooting • Stop the application • Switch off the power supply and pull out the mains plug. • Relieve the application of any loads, which may be released during the work. Before start-up • Make sure that the system has been installed as instructed in the User Manual. • Make sure that the v ...

  • Linak MEDLINE MJB - page 8

    8 Repairs In order to avoid the risk of malfunction, all r epairs must only be carried out by authorised LINAK workshops or repair ers, as special tools must be used and special gaskets must be fi tted. Products under warranty must also be r etur ned to authorised LINAK workshops. W ar ning! If any of the LINAK products ar e opened, there will be ...

  • Linak MEDLINE MJB - page 9

    9 Misc. on the MJB system W arranty and service life The LINAK warranty covers manufacturing defects in the pr oducts, starting from the date of manufacture. Ther e is 18 months’ warranty for MEDLINE and CARELINE products. The warranty is limited to the value of the LINAK pr oduct. LINAK’ s guarantee is only valid so far as the products have be ...

  • Linak MEDLINE MJB - page 10

    10 MJB - GA TEW A Y variant, 504-01 & 504-02 : The MJB is a simple gateway interface, which can connect the bed to the infrastructure of the hospital or nursing homes. The Gateway can be used in combination with an Out of Bed Sensor , which makes it possible to indicate if the patient leaves the bed. The Gateway can also be used as a service/nu ...

  • Linak MEDLINE MJB - page 11

    11 Features: • Add-on value for hospital & care bed • Compact and functional design which allows easy mounting • 2 connections, Port1 OpenBus™ connection / Port 5 Gateway • Colour: Light grey RAL 7035 • Protection class IPX6 • Connection to OpenBus™ control box via modular plug cable, 6 wir es • Modular plug to Open end, see p ...

  • Linak MEDLINE MJB - page 12

    12 Relay 1 CB power mode Alarm level Relay state Mains unplugged, CB is in power down or the OpenBus™ is not running (Clock/ data is missing) Alarm NC* On mains or battery at “wake up” Bed Alarm** NC No Alarm NO Relay 2 CB power mode Alarm level Relay state Mains unplugged or CB is in power down No Alarm NC On mains or battery at “wake up ...

  • Linak MEDLINE MJB - page 13

    13 Precautions: • Always use locking mechanism and O-ring • Sockets not used must be fi tted with blind plugs to ensure IP Degr ee • When using the modular plug with open end, is it up to the customer to maintain the IP degree. • If the MJB – Gateway is used as open loop, there is a risk of not sending an alarm, when no mains are connect ...

  • Linak MEDLINE MJB - page 14

    14 Cable ordering nos.: Modular plug – open end: 0964140-3000 Please note, the slit is placed on the opposite side of the modular plug. This is to ensure that the cable is only being used for the Gateway MJB. ...

  • Linak MEDLINE MJB - page 15

    15 IP Protection Cleaning instrucions IPX0 Clean with a damp cloth IPX1 Clean with a damp cloth IPX2 Clean with a damp cloth IPX3 Clean with a damp cloth IPX4 Clean with a damp cloth IPX5 W ash with a brush and water , but not water under pressur e IPX6 X W ash with a brush and water . The water can be under pressur e, but the system must not be ho ...

  • Linak MEDLINE MJB - page 16

    16 W ar ning! The systems must not be sprayed directly with a high-pr essure cleaner . W ar ning! Interconnecting cables must r emain plugged in during cleaning to prevent the ingress of water . Precaution! When cleaned, water must never be sprayed upwar ds from underneath the bed, because it may enter the cable outlet. Envir onmental conditions: E ...

  • Linak MEDLINE MJB - page 17

    17 Modular plug with wide slit T o be used with LINAK products. Can be connected to all ports in the MJB, both ports with narrow and wide slit. Modular plug with narr ow slit T o be used with 3 rd party products. Can only be connected to ports in the MJB with narrow slit. This is to pr event 3 rd party products to interfere with the OpenBus TM conn ...

  • Linak MEDLINE MJB - page 18

    18 T ype B equipment, as per EN 60601-1 Protection against contact/foreign matter (first character) and water (second character) as per EN60529 Class 2 equipment For indoor use Double insulated transformer Protective earth Alter nating Curr ent Direct curr ent Attention, consult accompanying documents Key to symbols Lock function Release function C ...

  • Linak MEDLINE MJB - page 19

    19 Demko approval Fimko approval Australian approval mark Australian approval mark Recognised - Component Mark Canadian Recognised - Component Mark Recognised Component Mark for Canada and the United States T -Mark RW-Tüv approval Tüv .Produkt Service TÜVRheinland ETL C-ETL LGA UL Listing Mark C-UL Listing Mark C-UL US Listing Mark UL Listing Ma ...

  • Linak MEDLINE MJB - page 20

    20 MJB MJB - Modular Junction Box DRA WING APPENDIX MJB ...

  • Linak MEDLINE MJB - page 21

    21 LINAK APPLICA TION POLICY The purpose of the application policy is to defi ne areas of r esponsibilities in relation to applying a LINAK product defi ned as har dware, softwar e, technical advice, etc. related to an existing or new customer application. LINAK products as defi ned above ar e applicable for a wide range of applications within t ...

  • Linak MEDLINE MJB - page 22

    22 ...

  • Linak MEDLINE MJB - page 23

    23 ...

  • Linak MEDLINE MJB - page 24

    Copyright © LINAK 2010.10 MA-M9-02-348 LINAK A/S reserve the right to make technical alterations T erms of use The user is responsible for determining the suitability of LINAK products for specifi c application. LINAK takes great care in providing accurate and up-to-date information on its products. However , due to continuous development in orde ...

Fabricant Linak Catégorie Network Router

Les documents que nous recevons du fabricant de l'appareilLinak MEDLINE MJB peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Linak
- manuels d’utilisations MEDLINE MJB
- fiches produit Linak
- dépliants
- ou étiquettes-énergie Linak MEDLINE MJB
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Linak MEDLINE MJB.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Linak MEDLINE MJB, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Linak MEDLINE MJB. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Linak MEDLINE MJB.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Linak MEDLINE MJB, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Linak MEDLINE MJB par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Linak MEDLINE MJB.

Le manuel d’utilisation complet Linak, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Linak MEDLINE MJB - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Linak MEDLINE MJB, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLinak MEDLINE MJB qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Linak MEDLINE MJB - qui devraient nous aider dans les premières étapes lors de l'utilisation Linak MEDLINE MJB
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Linak MEDLINE MJB
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Linak MEDLINE MJB dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Linak MEDLINE MJB?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Linak MEDLINE MJB, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Linak MEDLINE MJB il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)