Manuel d’utilisation Mad Catz 5MPRA6E3-148

12 pages 0.21 mb
Télécharger

Aller à la page of 12

Summary
  • Mad Catz 5MPRA6E3-148 - page 1

    DYNA-GLAS TM CENTRIFUGAL PUMPS WITH INTEGRAL TRAP O W N E R’ S M A N U A L INST ALLA TION, OPERA TION & P ARTS 5MPRA Series MODELS 5MPRA6C-146 5MPRA6C3-146 5MPRA6D-147 5MPRA6D3-147 5MPRA6E-148 5MPRA6E3-148 5MPRA6F-156 5MPRA6F3-156 STA-RITE FOREIGN SALES CORP. 175 WRIGHT STREET, DELAVAN, WISCONSIN 53115 USA Telephone: (414) 728-5551; Telefax: ...

  • Mad Catz 5MPRA6E3-148 - page 2

    2 ‘5MPRA ’ SERIES PUMP WITH TRAP To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-Rite ‘5MPRA’ Series Self-priming Centrifugal pump: • Is designed for use with swimming pools or as a centrifugal pump. • Is an excellent performer; durable, reliable. T able ...

  • Mad Catz 5MPRA6E3-148 - page 3

    3 READ AND FOLLOW ALL INSTRUCTIONS! This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert to the potential for personal injury. warns about hazards that will cause death, serious personal injury, or major property damage if ignored. warns about hazards tha ...

  • Mad Catz 5MPRA6E3-148 - page 4

    4 INST ALL A TION Only qualified, licensed personnel should install pump and wiring. Pump mount must: Be solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.) Allow pump suction inlet height to be as close to water level as possible. Pump will not lift water more than 10'(3m). Allow use of short, di ...

  • Mad Catz 5MPRA6E3-148 - page 5

    5 Piping: Use at least 1-1/2" (38mm) pipe (use 2"(51mm) pipe if possible). Increase size if a long run is needed. When using 1-1/2" pipe, connect to pump with 1-1/2" to 2" (38 to 51mm) reducing adapter. To avoid strains on the pump, support both suction and discharge pipes inde- pendently. Place these supports near the pump ...

  • Mad Catz 5MPRA6E3-148 - page 6

    6 ELECTRICAL Ground motor before connecting to electrical power supply. Failure to ground motor can cause severe or fatal electrical shock hazard. Do not ground to a gas supply line. To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections. Ground Fault Circuit Interrupter (GFCI) tripping indica ...

  • Mad Catz 5MPRA6E3-148 - page 7

    7 OPERA TION NOTICE: NEVER run pump dry. Running pump dry may damage seals, caus- ing leakage and flooding. Fill pump with water before starting motor. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GATE VALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. If pump is being pressure tested ...

  • Mad Catz 5MPRA6E3-148 - page 8

    8 Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see instructions below). Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do not cover pump with plastic. For outdoor/unprotected installations: 1. Enclose entire system in a weatherproof enclosure. 2 ...

  • Mad Catz 5MPRA6E3-148 - page 9

    9 PUMP SER VICE Pump should only be serviced by qualified personnel. Be sure to prime pump (Pg. 7) before starting. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GA TE V ALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. To avoid dangerous or fatal electrical shock hazard, turn OFF powe ...

  • Mad Catz 5MPRA6E3-148 - page 10

    10 Pump Reassembly/Installing New Seal 1. Ceramic seat must be clean and free of dirt, grease, dust, etc. Wet outer edge with small amount of liquid detergent; press ceramic seat into seal plate cavity firmly and squarely with finger pressure (Fig. 6). 2. If ceramic seat will not locate properly, remove it, place face up on bench and reclean cavity ...

  • Mad Catz 5MPRA6E3-148 - page 11

    11 Clogged pipe/trap/impeller, worn impeller: 7. Make sure suction trap is not clogged; if it is, clean trap and strainer. 8. Make sure impeller is not clogged (follow steps 1 through 7 under “Removing Old Seal”, Page 9; check impeller for clogging; follow steps 7 through 11 under “Installing New Seal”, Page 10, for reassembly). 9. Impeller ...

  • Mad Catz 5MPRA6E3-148 - page 12

    1 2 3 4 5 6 7 8 8A 8B Box A Box A 11 12 13 14 15B 15A 16 17 18 19 20 21 22 23 9 10 012 0394 BOX A For quick disconnect pipe connection parts: Adapter Union Pkg ..................... 11201-0153 O-Rings (2) .................... 35505- 1318 Key Part No. Description Qty. 1 Motor 115/230 Volt/1 Phase 1 Chart at right 2 Screw #10-32x1/2" 1 U30-692SS ...

Fabricant Mad Catz Catégorie Water Pump

Les documents que nous recevons du fabricant de l'appareilMad Catz 5MPRA6E3-148 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Mad Catz
- manuels d’utilisations 5MPRA6E3-148
- fiches produit Mad Catz
- dépliants
- ou étiquettes-énergie Mad Catz 5MPRA6E3-148
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Mad Catz 5MPRA6E3-148.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Mad Catz 5MPRA6E3-148, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Mad Catz 5MPRA6E3-148. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Mad Catz 5MPRA6E3-148.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Mad Catz 5MPRA6E3-148, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Mad Catz 5MPRA6E3-148 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Mad Catz 5MPRA6E3-148.

Le manuel d’utilisation complet Mad Catz, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Mad Catz 5MPRA6E3-148 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Mad Catz 5MPRA6E3-148, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lMad Catz 5MPRA6E3-148 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Mad Catz 5MPRA6E3-148 - qui devraient nous aider dans les premières étapes lors de l'utilisation Mad Catz 5MPRA6E3-148
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Mad Catz 5MPRA6E3-148
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Mad Catz 5MPRA6E3-148 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Mad Catz 5MPRA6E3-148?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Mad Catz 5MPRA6E3-148, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Mad Catz 5MPRA6E3-148 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)