    DYNA-GLAS TM CENTRIFUGAL PUMPS WITH INTEGRAL TRAP O W N E R’ S M A N U A L INST ALLA TION, OPERA TION & P ARTS 5MPRA Series MODELS 5MPRA6C-146 5MPRA6C3-146 5MPRA6D-147 5MPRA6D3-147 5MPRA6E-148 5MPRA6E3-148 5MPRA6F-156 5MPRA6F3-156 STA-RITE FOREIGN SALES CORP. 175 WRIGHT STREET, DELAVAN, WISCONSIN 53115 USA Telephone: (414) 728-5551; Telefax: ...

  • Mad Catz 5MPRA6E3-148 - page 2

    2 ‘5MPRA ’ SERIES PUMP WITH TRAP To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-Rite ‘5MPRA’ Series Self-priming Centrifugal pump: • Is designed for use with swimming pools or as a centrifugal pump. • Is an excellent performer; durable, reliable. T able ...

  • Mad Catz 5MPRA6E3-148 - page 3

    3 READ AND FOLLOW ALL INSTRUCTIONS! This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert to the potential for personal injury. warns about hazards that will cause death, serious personal injury, or major property damage if ignored. warns about hazards tha ...

  • Mad Catz 5MPRA6E3-148 - page 4

    4 INST ALL A TION Only qualified, licensed personnel should install pump and wiring. Pump mount must: Be solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.) Allow pump suction inlet height to be as close to water level as possible. Pump will not lift water more than 10'(3m). Allow use of short, di ...

  • Mad Catz 5MPRA6E3-148 - page 5

    5 Piping: Use at least 1-1/2" (38mm) pipe (use 2"(51mm) pipe if possible). Increase size if a long run is needed. When using 1-1/2" pipe, connect to pump with 1-1/2" to 2" (38 to 51mm) reducing adapter. To avoid strains on the pump, support both suction and discharge pipes inde- pendently. Place these supports near the pump ...

  • Mad Catz 5MPRA6E3-148 - page 6

    6 ELECTRICAL Ground motor before connecting to electrical power supply. Failure to ground motor can cause severe or fatal electrical shock hazard. Do not ground to a gas supply line. To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections. Ground Fault Circuit Interrupter (GFCI) tripping indica ...

  • Mad Catz 5MPRA6E3-148 - page 7

    7 OPERA TION NOTICE: NEVER run pump dry. Running pump dry may damage seals, caus- ing leakage and flooding. Fill pump with water before starting motor. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GATE VALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. If pump is being pressure tested ...

  • Mad Catz 5MPRA6E3-148 - page 8

    8 Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see instructions below). Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do not cover pump with plastic. For outdoor/unprotected installations: 1. Enclose entire system in a weatherproof enclosure. 2 ...

  • Mad Catz 5MPRA6E3-148 - page 9

    9 PUMP SER VICE Pump should only be serviced by qualified personnel. Be sure to prime pump (Pg. 7) before starting. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GA TE V ALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. To avoid dangerous or fatal electrical shock hazard, turn OFF powe ...

  • Mad Catz 5MPRA6E3-148 - page 10

    10 Pump Reassembly/Installing New Seal 1. Ceramic seat must be clean and free of dirt, grease, dust, etc. Wet outer edge with small amount of liquid detergent; press ceramic seat into seal plate cavity firmly and squarely with finger pressure (Fig. 6). 2. If ceramic seat will not locate properly, remove it, place face up on bench and reclean cavity ...

  • Mad Catz 5MPRA6E3-148 - page 11

    11 Clogged pipe/trap/impeller, worn impeller: 7. Make sure suction trap is not clogged; if it is, clean trap and strainer. 8. Make sure impeller is not clogged (follow steps 1 through 7 under “Removing Old Seal”, Page 9; check impeller for clogging; follow steps 7 through 11 under “Installing New Seal”, Page 10, for reassembly). 9. Impeller ...

  • Mad Catz 5MPRA6E3-148 - page 12

    1 2 3 4 5 6 7 8 8A 8B Box A Box A 11 12 13 14 15B 15A 16 17 18 19 20 21 22 23 9 10 012 0394 BOX A For quick disconnect pipe connection parts: Adapter Union Pkg ..................... 11201-0153 O-Rings (2) .................... 35505- 1318 Key Part No. Description Qty. 1 Motor 115/230 Volt/1 Phase 1 Chart at right 2 Screw #10-32x1/2" 1 U30-692SS ...

Fabbricante Mad Catz Categoria Water Pump

I documenti che otteniamo dal fabbricante del dispositivoMad Catz 5MPRA6E3-148 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Mad Catz
- manuali per l’uso 5MPRA6E3-148
- schede prodotto Mad Catz
- opuscoli
- o etichette energetiche Mad Catz 5MPRA6E3-148
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Mad Catz 5MPRA6E3-148.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Mad Catz 5MPRA6E3-148, manuali di manutenzione, brevi manuali o manuali utente Mad Catz 5MPRA6E3-148. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Mad Catz 5MPRA6E3-148.

Manuali per l’uso simili

Manuale completo del dispositivo Mad Catz 5MPRA6E3-148, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Mad Catz 5MPRA6E3-148 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Mad Catz 5MPRA6E3-148.

Il manuale per l’uso completo Mad Catz, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Mad Catz 5MPRA6E3-148 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Mad Catz 5MPRA6E3-148, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Mad Catz 5MPRA6E3-148 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Mad Catz 5MPRA6E3-148 - che ci dovrebbe aiutare nei primi passi durante l'uso Mad Catz 5MPRA6E3-148
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Mad Catz 5MPRA6E3-148
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Mad Catz 5MPRA6E3-148 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Mad Catz 5MPRA6E3-148?

Utilizza il modulo sottostante

Se non hai risolto il problema con Mad Catz 5MPRA6E3-148 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Mad Catz 5MPRA6E3-148 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)