    Only qualified personnel should install this unit. Personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Impr oper installation can result in electric shock, possible injury due to coming in contact with moving parts, as well as other potential hazards. Other considerations may be requ ...

  • Greenheck Fan 464696 - page 2

    2 Model VFCD/VFCB V ertical Fan Coil ® The unit should be stored at least 3½ in. (89 mm) of f the floor on wooden blocks covered with moistur e proof paper or polyethylene sheathing. Aisles between parts and along all walls should be provided to permit air circulation and space for inspection. Inspection and Maintenance during Storage While in s ...

  • Greenheck Fan 464696 - page 3

    3 Model VFCD/VFCB V ertical Fan Coil ® T able of Contents Installation U n i t L a y o u t .............................. . 3 Mounting Instructions ...................... 3 Unit Dimensions / Weights .................. 4 Inlet and Outlet Duct Details . . . . . . . . . . . . . . . . 4 C o i l D e t a i l s ............................. 5 - 6 F i l t ...

  • Greenheck Fan 464696 - page 4

    4 Model VFCD/VFCB V ertical Fan Coil ® Chilled Water Coil Conditions Fin Height: 22.5 Fin Width: Width-7 Fins Per Inch: 10 Fin Surface: B Circuiting: Half Ent. Air DB: 80 Ent. Air WB: 67 Fluid T ype: Water Ent. Fluid: 45 Leaving Fluid: 55 Note: Coil Conditions can be changed to obtain different coil performances MAX DEL TA T (CW) CFM 800 600 1600 ...

  • Greenheck Fan 464696 - page 5

    5 Model VFCD/VFCB V ertical Fan Coil ® Coil Dimensions NOTE Fluid enters the coil from the bottom connection (Inlet) and exits from the top (Outlet). Hot W ater • 1 and 2 Row Unit Size A B C D 600 20.00 22.50 22.63 0.875 800 20.00 22.50 22.63 0.875 1300 24.00 27.50 22.63 0.875 1600 24.75 27.25 22.63 0.875 2000 24.75 27.50 25.13 0.875 2400 24.75 ...

  • Greenheck Fan 464696 - page 6

    6 Model VFCD/VFCB V ertical Fan Coil ® NOTE With airflow from left to right, the fluid enters the coil from the bottom connection (Inlet) and exits from the top (Outlet). The other two coil connections should be capped off (Cap). Chilled W ater • 4, 6 or 8 Row C B A E D F 1.5 in. 2 in. 3 in. 0.75 in. 1 in. Outlet Drain Connection 3.75 in. Outlet ...

  • Greenheck Fan 464696 - page 7

    7 Model VFCD/VFCB V ertical Fan Coil ® Filter Sizes and Quantity Model V ertical Filter Size (inches) Quantity Face Area (ft 2 ) VFCD/VFCD-600 20 x 24 1 2.7 VFCD/VDFCB-800 20 x 24 1 2.7 VFCD-VFCB-1300 20 x 24 1 2.7 VFCD/VFCB-1600 24 x 24 1 3.6 VFCD/VFCB-2000 16 x 25 2 4.7 VFCD/VFCB-2400 16 x 25 2 4.7 VFCD/VFCB-3000 24 x 24 2 6.7 All dimensions are ...

  • Greenheck Fan 464696 - page 8

    8 Model VFCD/VFCB V ertical Fan Coil ® 4. Air Volume Check and Measurement Along with the building balance, the unit’ s air volume (cfm) should be measured and compar ed with its rated air volume. This unit is flexible for varying air volume, but the actual air volume should be known for making final adjustments. The most accurate way to measu ...

  • Greenheck Fan 464696 - page 9

    9 Model VFCD/VFCB V ertical Fan Coil ® Speed Contr ols Speed controls may be used on Model VFCD fans for manual adjustment of the fan’ s performance (for final system balancing) or to control the fan’ s output in confined spaces, such as conference or meeting rooms. The fan can be adjusted to 60% of design airflow with a speed control. This ...

  • Greenheck Fan 464696 - page 10

    10 Model VFCD/VFCB V ertical Fan Coil ® Symptom Possible Cause Corrective Action Blower fails to operate Blown fuse or open circuit br eaker Replace fuse or reset cir cuit breaker and check amps Broken fan belt Replace Defective motor or capacitor Replace Motor starter overloaded Reset starter and check amps Motor overamps Airflow too high Check a ...

  • Greenheck Fan 464696 - page 11

    11 Model VFCD/VFCB V ertical Fan Coil ® Hot W ater , Chilled W ater and DX Coils 1. Piping should be in accordance with accepted industry standards. Pipework should be supported independently of the coils. Water pipes are copper with sweat connections. USE WET TOWEL TO AVOID BURNING COIL CONNECTION GROMMETS. When installing coupling, do not apply ...

  • Greenheck Fan 464696 - page 12

    12 Model VFCD/VFCB V ertical Fan Coil ® 2P = minimum 2P = minimum Drain Pan / Drain T rap Drain Pan / Drain T rap Drain lines and traps should be run full size from the drain pan connection. Drain pans should have drain lines and traps to permit the condensate from the coils to drain freely . On all units with drain pans, the trap depth and the di ...

  • Greenheck Fan 464696 - page 13

    13 Model VFCD/VFCB V ertical Fan Coil ® Y early Bearings — Most bearings are permanently lubricated and requir e no further lubrication under normal use. Normal use being considered -20ºF to 120ºF and in a relatively clean envir onment. Some bearings are r e-lubricatable and will need to be re- greased depending on fan use. Check your bearings ...

  • Greenheck Fan 464696 - page 14

    14 Model VFCD/VFCB V ertical Fan Coil ® Coil Maintenance Start-Up Documentation CAUTION Fin edges are sharp. Coils must be clean to obtain maximum performance. Check once a year under normal operating conditions and, if dirty , brush or vacuum clean. Soiled fins reduce the capacity of the coil, demand more energy fr om the fan, and create an envi ...

  • Greenheck Fan 464696 - page 15

    15 Model VFCD/VFCB V ertical Fan Coil ® Maintenance Log Date __________________ Time _____________ AM/PM Notes:___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ____________________________________________ ...

  • Greenheck Fan 464696 - page 16

    Greenheck warrants this equipment to be fr ee from defects in material and workmanship for a period of one year fr om the purchase date. Any units or parts which pr ove defective during the warranty period will be replaced at our option when returned to our factory , transportation pr epaid. Motors are warranted by the motor manufacturer for a peri ...

Fabricant Greenheck Fan Catégorie Fan

Les documents que nous recevons du fabricant de l'appareilGreenheck Fan 464696 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Greenheck Fan
- manuels d’utilisations 464696
- fiches produit Greenheck Fan
- dépliants
- ou étiquettes-énergie Greenheck Fan 464696
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Greenheck Fan 464696.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Greenheck Fan 464696, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Greenheck Fan 464696. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Greenheck Fan 464696.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Greenheck Fan 464696, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Greenheck Fan 464696 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Greenheck Fan 464696.

Le manuel d’utilisation complet Greenheck Fan, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Greenheck Fan 464696 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Greenheck Fan 464696, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGreenheck Fan 464696 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Greenheck Fan 464696 - qui devraient nous aider dans les premières étapes lors de l'utilisation Greenheck Fan 464696
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Greenheck Fan 464696
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Greenheck Fan 464696 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Greenheck Fan 464696?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Greenheck Fan 464696, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Greenheck Fan 464696 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)