  • Greenheck Fan 464696 - page 1

    Only qualified personnel should install this unit. Personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Impr oper installation can result in electric shock, possible injury due to coming in contact with moving parts, as well as other potential hazards. Other considerations may be requ ...

  • Greenheck Fan 464696 - page 2

    2 Model VFCD/VFCB V ertical Fan Coil ® The unit should be stored at least 3½ in. (89 mm) of f the floor on wooden blocks covered with moistur e proof paper or polyethylene sheathing. Aisles between parts and along all walls should be provided to permit air circulation and space for inspection. Inspection and Maintenance during Storage While in s ...

  • Greenheck Fan 464696 - page 3

    3 Model VFCD/VFCB V ertical Fan Coil ® T able of Contents Installation U n i t L a y o u t .............................. . 3 Mounting Instructions ...................... 3 Unit Dimensions / Weights .................. 4 Inlet and Outlet Duct Details . . . . . . . . . . . . . . . . 4 C o i l D e t a i l s ............................. 5 - 6 F i l t ...

  • Greenheck Fan 464696 - page 4

    4 Model VFCD/VFCB V ertical Fan Coil ® Chilled Water Coil Conditions Fin Height: 22.5 Fin Width: Width-7 Fins Per Inch: 10 Fin Surface: B Circuiting: Half Ent. Air DB: 80 Ent. Air WB: 67 Fluid T ype: Water Ent. Fluid: 45 Leaving Fluid: 55 Note: Coil Conditions can be changed to obtain different coil performances MAX DEL TA T (CW) CFM 800 600 1600 ...

  • Greenheck Fan 464696 - page 5

    5 Model VFCD/VFCB V ertical Fan Coil ® Coil Dimensions NOTE Fluid enters the coil from the bottom connection (Inlet) and exits from the top (Outlet). Hot W ater • 1 and 2 Row Unit Size A B C D 600 20.00 22.50 22.63 0.875 800 20.00 22.50 22.63 0.875 1300 24.00 27.50 22.63 0.875 1600 24.75 27.25 22.63 0.875 2000 24.75 27.50 25.13 0.875 2400 24.75 ...

  • Greenheck Fan 464696 - page 6

    6 Model VFCD/VFCB V ertical Fan Coil ® NOTE With airflow from left to right, the fluid enters the coil from the bottom connection (Inlet) and exits from the top (Outlet). The other two coil connections should be capped off (Cap). Chilled W ater • 4, 6 or 8 Row C B A E D F 1.5 in. 2 in. 3 in. 0.75 in. 1 in. Outlet Drain Connection 3.75 in. Outlet ...

  • Greenheck Fan 464696 - page 7

    7 Model VFCD/VFCB V ertical Fan Coil ® Filter Sizes and Quantity Model V ertical Filter Size (inches) Quantity Face Area (ft 2 ) VFCD/VFCD-600 20 x 24 1 2.7 VFCD/VDFCB-800 20 x 24 1 2.7 VFCD-VFCB-1300 20 x 24 1 2.7 VFCD/VFCB-1600 24 x 24 1 3.6 VFCD/VFCB-2000 16 x 25 2 4.7 VFCD/VFCB-2400 16 x 25 2 4.7 VFCD/VFCB-3000 24 x 24 2 6.7 All dimensions are ...

  • Greenheck Fan 464696 - page 8

    8 Model VFCD/VFCB V ertical Fan Coil ® 4. Air Volume Check and Measurement Along with the building balance, the unit’ s air volume (cfm) should be measured and compar ed with its rated air volume. This unit is flexible for varying air volume, but the actual air volume should be known for making final adjustments. The most accurate way to measu ...

  • Greenheck Fan 464696 - page 9

    9 Model VFCD/VFCB V ertical Fan Coil ® Speed Contr ols Speed controls may be used on Model VFCD fans for manual adjustment of the fan’ s performance (for final system balancing) or to control the fan’ s output in confined spaces, such as conference or meeting rooms. The fan can be adjusted to 60% of design airflow with a speed control. This ...

  • Greenheck Fan 464696 - page 10

    10 Model VFCD/VFCB V ertical Fan Coil ® Symptom Possible Cause Corrective Action Blower fails to operate Blown fuse or open circuit br eaker Replace fuse or reset cir cuit breaker and check amps Broken fan belt Replace Defective motor or capacitor Replace Motor starter overloaded Reset starter and check amps Motor overamps Airflow too high Check a ...

  • Greenheck Fan 464696 - page 11

    11 Model VFCD/VFCB V ertical Fan Coil ® Hot W ater , Chilled W ater and DX Coils 1. Piping should be in accordance with accepted industry standards. Pipework should be supported independently of the coils. Water pipes are copper with sweat connections. USE WET TOWEL TO AVOID BURNING COIL CONNECTION GROMMETS. When installing coupling, do not apply ...

  • Greenheck Fan 464696 - page 12

    12 Model VFCD/VFCB V ertical Fan Coil ® 2P = minimum 2P = minimum Drain Pan / Drain T rap Drain Pan / Drain T rap Drain lines and traps should be run full size from the drain pan connection. Drain pans should have drain lines and traps to permit the condensate from the coils to drain freely . On all units with drain pans, the trap depth and the di ...

  • Greenheck Fan 464696 - page 13

    13 Model VFCD/VFCB V ertical Fan Coil ® Y early Bearings — Most bearings are permanently lubricated and requir e no further lubrication under normal use. Normal use being considered -20ºF to 120ºF and in a relatively clean envir onment. Some bearings are r e-lubricatable and will need to be re- greased depending on fan use. Check your bearings ...

  • Greenheck Fan 464696 - page 14

    14 Model VFCD/VFCB V ertical Fan Coil ® Coil Maintenance Start-Up Documentation CAUTION Fin edges are sharp. Coils must be clean to obtain maximum performance. Check once a year under normal operating conditions and, if dirty , brush or vacuum clean. Soiled fins reduce the capacity of the coil, demand more energy fr om the fan, and create an envi ...

  • Greenheck Fan 464696 - page 15

    15 Model VFCD/VFCB V ertical Fan Coil ® Maintenance Log Date __________________ Time _____________ AM/PM Notes:___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ____________________________________________ ...

  • Greenheck Fan 464696 - page 16

    Greenheck warrants this equipment to be fr ee from defects in material and workmanship for a period of one year fr om the purchase date. Any units or parts which pr ove defective during the warranty period will be replaced at our option when returned to our factory , transportation pr epaid. Motors are warranted by the motor manufacturer for a peri ...

Fabbricante Greenheck Fan Categoria Fan

I documenti che otteniamo dal fabbricante del dispositivoGreenheck Fan 464696 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Greenheck Fan
- manuali per l’uso 464696
- schede prodotto Greenheck Fan
- opuscoli
- o etichette energetiche Greenheck Fan 464696
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Greenheck Fan 464696.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Greenheck Fan 464696, manuali di manutenzione, brevi manuali o manuali utente Greenheck Fan 464696. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Greenheck Fan 464696.

Manuali per l’uso simili

Manuale completo del dispositivo Greenheck Fan 464696, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Greenheck Fan 464696 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Greenheck Fan 464696.

Il manuale per l’uso completo Greenheck Fan, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Greenheck Fan 464696 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Greenheck Fan 464696, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Greenheck Fan 464696 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Greenheck Fan 464696 - che ci dovrebbe aiutare nei primi passi durante l'uso Greenheck Fan 464696
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Greenheck Fan 464696
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Greenheck Fan 464696 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Greenheck Fan 464696?

Utilizza il modulo sottostante

Se non hai risolto il problema con Greenheck Fan 464696 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Greenheck Fan 464696 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)