Manuel d’utilisation Bunn DV

24 pages 2.59 mb
Télécharger

Aller à la page of 24

Summary
  • Bunn DV - page 1

    H10X/H5X H5E/DV PC H5 ELEMENT With Digital Control Board SER VICE MANU AL BUNN-O-MA TIC CORPORA TION POST OFFICE BO X 3227 SPRINGFIELD , ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 T o ensure you have the latest revision of the manual or to obtain the illustrated parts catalog, please visit the Bunn-O-Matic website, at www .bunn. ...

  • Bunn DV - page 2

    2 BUNN-O-MA TIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specifi ed below: 2 years parts and 1 year labor . 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years parts and 1 year ...

  • Bunn DV - page 3

    3 WARNING - Inspection, testing, and repair of electrical equipment should be performed only by qualifi ed ser vice personnel. Disconnect the dispenser fromthe power source when servicing, except when electrical tests are required and the test procedure specifi cally states to connect the dispenser to the power sour ce. 42311 071310 CONTENTS T ro ...

  • Bunn DV - page 4

    4 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Ser vice Department. • Inspection, testing, and repair of electrical equipment should be performed only by qu ...

  • Bunn DV - page 5

    5 TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Equipment will not operate (cont.) Automatic refi ll will not oper - ate after drawing hot water . Water fl ows into the tank con- tinuously (Dispenser discon- nected from power source). Water fl ows into the tank con- tinuously (Dispenser connect- ed to power source). Water is cold. 2. Saf ...

  • Bunn DV - page 6

    6 TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Water boils continuously . Dispenser is making unusual noises. Ready indicator will not light. 1. T emperature control 2. Lime build-up 1. Plumbing lines 3. Water supply 1. T emperature control 2. Ready Indicator LED Refer to Service – electronic controls for testing procedures. Inspect the ...

  • Bunn DV - page 7

    7 Faceplate Removal - H5 ELEMENT : After removing top cover , remove the two upper screws securing the faceplate. Carefully lift faceplate straight up until the three lower screws clear the key holes. The check valve, electronic control assembly , safety overfl ow switch, solenoid valve, overfl ow tube tempera- ture sensor and terminal block are ...

  • Bunn DV - page 8

    8 SERVICE Electronic Controls FIG. 8a ELECTRONIC CONTROL P4093.35 V oltage present at Solenoid V alve ? V oltage present at Solenoid V alve ? Overflow Cup Full ? Remove Power Disconnect Level Probe Retry Drain cup No Ye s Ye s Ye s Ye s No No No H5E, H5X LIQUID LEVEL CONTROL PROBLEM: Does Not Refill Does Water Flow ? Replace Probe Unplug Ready Lamp ...

  • Bunn DV - page 9

    9 SERVICE (cont.) Electronic Controls (cont.) Liquid Level Control T est Procedure 1. Disconnect the dispenser from the power sour ce. 2. Check the voltage across terminals 3 & 4 of the electronic control board with a voltmeter . Connect the dispenser to the power source. The indication must be: a.) 100 to 120 volts ac for 100 to 120 volt model ...

  • Bunn DV - page 10

    10 Electronic Controls (cont.) 7. Reconnect the pink wire to terminal 5 of the elec- tronic control assembly . 8. Loosen the compression fi tting, remove the probe from the tank lid, and inspect it for mineral depos- its. Replace it if necessary . Keep the exposed ends of the probe away from any metal surface of the dispenser . 9. Check the voltag ...

  • Bunn DV - page 11

    11 SERVICE (cont.) Electronic Controls (cont.) If voltage was present as described, the temperature control of the system is operating properly . If voltage was not present as described, contact Bunn-O-Matic to order an electronic control board and temperature sensor for evaluation and proceed to #9. 6. Replace the electronic control board. 7. Chec ...

  • Bunn DV - page 12

    12 SERVICE (cont.) Limit Thermostat Location: The limit thermostat is located on the tank lid. T o test the limit thermostat, access will also be needed to the terminal block located at the rear of the dispenser . If voltage was present as described, reconnect the black wire and proceed to #5. If voltage was not present as described, refer to the W ...

  • Bunn DV - page 13

    13 SERVICE (cont.) Safety Overfl ow Switch Location: The safety overfl ow switch is located inside the rear of the dispenser inside the copper overfl ow cup. For testing or removal of the safety overfl ow switch, access may also be needed by removing the two screws attaching the electronic control assembly to its mount- ing bracket. T est Proce ...

  • Bunn DV - page 14

    14 SERVICE (cont.) Solenoid Valve (Late Models) Location: The solenoid valve is located inside the rear of the dispenser on the right side near the bottom. T o test the solenoid valve, access will also be needed to the electronic control board. sound after approximately 5 seconds, as the coil magnet attracts the plunger . 8. Disconnect the dispense ...

  • Bunn DV - page 15

    15 Solenoid Valve (Early Models) Location: The solenoid valve is located behind the large access panel on the left side of the dispenser . T o test the solenoid valve, access will also be needed to the electronic control board. BUNN 90 psig max operating pressure Strainer/Flow Control # 22300.0750 (Repl. Flow Washer #20526.0750) (Repl. Screen #2372 ...

  • Bunn DV - page 16

    16 SERVICE (cont.) T ank Heater Location: The tank heater is located in the tank lid. T est Procedure: 1. Disconnect the dispenser from the power sour ce. 2. Check the voltage across the terminals of the tank heater with a voltmeter . Connect the dispenser to the power source. The indication must be: a.) 100 to 120 volts ac for 100 to 120 volt mode ...

  • Bunn DV - page 17

    Steam Sensor (Thermistor) Location: The thermistor is located on the end of the overfl ow tube above the overfl ow cup. T o test the thermistor , access will also be needed to the electronic control board. SERVICE (cont.) P1993 FIG. 17b LOCA TION H 10X P1993 FIG. 17a LOCA TION H 5X T est Procedure: 1. Disconnect the dispenser from the power sour ...

  • Bunn DV - page 18

    SERVICE (cont.) Dispense Valve (PC Only) Location: The Dispense Valve is located behind control panel. T est Procedures: 1. Check the valve for coil action. T urn on the valve with the dispense button. Listen carefully in the vicinity of the dispense valve for a click as the coil pulls the plunger in. If no sound is heard as described, proceed to # ...

  • Bunn DV - page 19

    42311 071310 19 RELA Y N.O. COM 3 1 5 4 2 F ACTORY J1-1 J1-5 H5-PC NO JUMPER Early H5E, H5X, H10X Install jumper thru ver . 1.04 J3-1 J3-5 J5-1 J4-1 J6-1 NO TE: no jumper used on an y Model star ting with ver . 1.08 J2 J7 MAIN CONTROL BOARD 1 2 3 4 + - + - USED ON H5X ONL Y 120V AC 2 WIRE + GND 120/208V AC 3 WIRE + GND 120/240V AC 3 WIRE + GND SING ...

  • Bunn DV - page 20

    42311 071310 20 230V AC 2 WIRE + GND SINGLE PHASE RELA Y N.O. COM 3 1 5 4 2 F ACTORY J1-1 J1-5 H5-PC NO JUMPER Early H5E, H5X, H10X Install jumper thru ver . 1.04 J3-1 J3-5 J5-1 J4-1 J6-1 NO TE: no jumper used on an y Model star ting with ver . 1.08 J2 J7 MAIN CONTROL BOARD 1 2 3 4 + - + - USED ON H5X ONL Y PINK-22 BLK-24 WHI-24 T ANK t° 39333.000 ...

  • Bunn DV - page 21

    42311 071310 21 BLU-14 BLK-14 BLK-14 T ANK HEA TER BLK-14 LIMIT THERMOST A T 200-240 VOL TS AC 2 WIRE + GND SINGLE PHASE USED ON H5X ONL Y RELA Y N.O. COM 3 1 5 4 2 F ACT ORY J1-1 J1-5 H5-PC NO JUMPER Early H5E, H5X, H10X Install jumper thru ver . 1.04 J3-1 J3-5 J5-1 J4-1 J6-1 NO TE: no jumper used on any Model star ting with ver . 1.08 J2 J7 MAIN ...

  • Bunn DV - page 22

    42311 071310 22 USED ON H5X ONL Y RELA Y N.O. COM 3 1 5 4 2 F ACTORY J1-1 J1-5 H5-PC NO JUMPER Early H5E, H5X, H10X Install jumper thru ver . 1.04 J3-1 J3-5 J5-1 J4-1 J6-1 NO TE: no jumper used on any Model star ting with ver . 1.08 J2 J7 MAIN CONTROL BOARD 1 2 3 4 + - + - 100-120 VOL TS AC or 200-240 VOL TS AC 2 WIRE + GND SINGLE PHASE PINK-22 GRN ...

  • Bunn DV - page 23

    42311 050511 23 RELA Y 3 1 5 4 2 J1-1 J1-5 J3-1 J3-5 J5-1 J4-1 J6-1 J7 PINK-22 GRN-18 WHI/BLU-18 T ANK t° MAIN CONTROL BOARD 1 2 3 4 0-13.8V AC 0-3.3VDC 0-3.3VDC GRY GRY t ° + - + - WHI/VIO-14 RED-18 BLU-14 BLU-14 RED-18 BLK-14 BLK-18 BLK-18 L1 L2 RED RED BLK-18 OVERFLOW PROTECTION SWITCH BLK-14 T ANK HEA TER BLK-14 LIMIT THERMOST A T LIMIT THERM ...

  • Bunn DV - page 24

    42311 050511 24 RELA Y J1-1 J1-5 J3-1 J2-1 J4-1 J2 MAIN CONTROL BOARD 1 2 3 4 + - + - USED ON H5X ONL Y 100-240V AC 2 WIRE + GND SINGLE PHASE PINK BLK WHI T ANK t° 44657.0000B 05/11 ©2011 BUNN-O-MA TIC CORPORA TION GRY GRY t ° STEAM SENSOR TEMP PROBE + - SCHEMA TIC WIRING DIAGRAM H5 ELEMENT GRN/YEL L1 RED WHI/BLU BRN/WHI WHI/RED T ANK HEA TER L2 ...

Fabricant Bunn Catégorie Coffeemaker

Les documents que nous recevons du fabricant de l'appareilBunn DV peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Bunn
- manuels d’utilisations DV
- fiches produit Bunn
- dépliants
- ou étiquettes-énergie Bunn DV
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Bunn DV.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Bunn DV, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Bunn DV. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Bunn DV.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Bunn DV, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Bunn DV par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Bunn DV.

Le manuel d’utilisation complet Bunn, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Bunn DV - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Bunn DV, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBunn DV qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Bunn DV - qui devraient nous aider dans les premières étapes lors de l'utilisation Bunn DV
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Bunn DV
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Bunn DV dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Bunn DV?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Bunn DV, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Bunn DV il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)