Manuel d’utilisation Burnham 81441001R8-3/06

16 pages 1.69 mb
Télécharger

Aller à la page of 16

Summary
  • Burnham 81441001R8-3/06 - page 1

    81441001R8-3/06 Price - $2.00 R O F L A U N A M N O I T A L L A T S N I M A H N R U B A R - E S A BY ® PA G E 2 I=B=R RA TINGS 4 ASSEMBL Y CHAR T 5 SYSTEM TYPES 6 SERIES L OOP SYSTEMS 7 SERIES L OOP DESIGN 8 INST ALLA TION DET AILS 9 INST ALLA TION INSTR UCTIONS 10 ASSEMBL Y INSTR UCTIONS 14 SPECIAL APPLICA TIONS 16 W ARRANTY T ABLE OF CONTENTS r ...

  • Burnham 81441001R8-3/06 - page 2

    2 For Ratings at the following temperatures, multiply the 150° rating by the multiplier of the desired temperature. No. 9A Base-Ray ® I=B=R Ratings – Steam and Hot W ater ( 500 LBS/HR Flow Rate **) I=B=R Ratings are determined from tests made in accordance with the I=B=R Testing and Rating Code for Baseboard Type of Radiation, including an allo ...

  • Burnham 81441001R8-3/06 - page 3

    3 For Ratings at the following temperatures, multiply the 150° rating by the multiplier of the desired temperature. T emperature – Multiplier 150° - 1.0 140° - .82 No. 9A Base-Ray ® I=B=R Ratings – Steam and Hot W ater ( 2000 LBS/HR Flow Rate **) n i h t g n e L * t e e F l a e n i L m a e t S g n i t a R t e e F e r a u q S m a e t S g n i ...

  • Burnham 81441001R8-3/06 - page 4

    4 Dimensions and Speci ¿ cations BASE-RA Y T APPINGS- T apped 3/4" top and bot- tom of end sections. A 3/4" x 1/8" vent bushing is furnished with each Base-Ray Assembly . Only one air vent location need be used. Copper tubing is not recommended for steam appli- cations due to high heat loss through the tubing and thermal expansion n ...

  • Burnham 81441001R8-3/06 - page 5

    5 BASE-RA Y ® HYDRONICS T ypes of Systems Hydronic Heating Systems are classi ¿ ed according to the pip- ing arrangement and heating medium employed. BASE-RA Y is very versatile in that it may be used in almost all types of systems as noted below: 1. Series Loop Forced Circulation Hot W ater 2. One-Pipe Forced Circulation Hot W ater 3. T wo-Pipe ...

  • Burnham 81441001R8-3/06 - page 6

    6 SERIES LOOP SYSTEMS Installation Data This type of installation, in which the BASE-RA Y ® Assem- blies serve as part of the main, is the most economical way BASE-RA Y can be installed. Substantial savings in labor and material are realized in that one-pipe ¿ ttings, shut-of f valves, balancing cocks and additional piping are eliminated. Quality ...

  • Burnham 81441001R8-3/06 - page 7

    7 T o Design Series-Loop Base-Ray ® Installation – 1. Calculate the Heat Loss of each room using the procedure outlined in the I=B=R Heat Loss Calculation Guide No. H-21 or the ASHRAE Guide. 2. Using 210°F as design water temperature and 500 lbs/hr . as À ow rate, select length of BASE-RA Y Assembly for each room to produce desired output. (De ...

  • Burnham 81441001R8-3/06 - page 8

    8 Installation Details A BASE-RA Y ® heating system is extremely easy to install – no other heating system requires less labor . The same installa- tion practices that are used in an ordinary radiator system are followed. Use conventional methods in selecting boiler and pipe sizes, including mains, risers and branches. Supply and return connecti ...

  • Burnham 81441001R8-3/06 - page 9

    9 INST ALLA TION INSTRUCTIONS 1. W all Preparation: T o prevent excessive heat loss through the walls in back of BASE-RA Y ® , it is recommended that the stud space behind the Assemblies be insulated to a height of at least 12” above the À oor with 4” mineral wool batts (blanket or loose insulation may also be used) or other approved insulati ...

  • Burnham 81441001R8-3/06 - page 10

    10 5. Assembling BASE-RA Y ® BASE-RA Y is shipped assembled in lengths up to six (6) lineal feet – longer assemblies are shipped in two or more sub-assemblies for assembly on the job (see BASE-RA Y Assembly chart, page 4). One man can join tow sub- assemblies together in a matter of minutes providing he has a BASE-RA Y Assembly Clamp (available ...

  • Burnham 81441001R8-3/06 - page 11

    11 Stand Assemblies upright, place in position and fasten to the walls with T op Center Supports using the number shown in the table above. Insert T op Center Supports in Air Outlet opening of Sections opposite studs (stud locations determined in step 1). Use wood screw furnished with T op Center Support and screw into stud until tight, the longer ...

  • Burnham 81441001R8-3/06 - page 12

    12 8. Installation of Corner Plates INVER TED CORNER PLA TES – for inside corners – furnished in two types, 4-5/8” standard plate is used when Assemblies on adjoining walls extend to within 4-3/8” of the corner . If this distance is greater than 4-3/8” but less than 10-3/8”, the 10-5/8” plate is used. Extended Plate may be cut to desi ...

  • Burnham 81441001R8-3/06 - page 13

    13 ADJUST ABLE END CAPS & FILLER PIECES – Adjustable End Caps are available in both left-hand and right-hand patterns and are used in the same loca- tions as the standard end caps except the 9” length of the adjustable end caps makes it possible to ¿ ll in spaces of up to 7-1/2”. A knockout is also available in the ends for piping. Fille ...

  • Burnham 81441001R8-3/06 - page 14

    14 SPECIAL APPLICA TIONS BASE-RA Y ® INST ALLED ON THREE W ALLS OF ROOM – When BASE-RA Y is installed on three walls, expansion noises are sometimes created by the middle assembly when rigid piping is used to connect all three assemblies together . Flexibility can be gained by connecting two of the adjoining assemblies with a À exible connector ...

  • Burnham 81441001R8-3/06 - page 15

    15 All Base-Ray® repair parts may be obtained through your local Burnham Wholesale Distributor . Should you require assistance in locating a Burnham Distributor in your area, or have questions regarding the availability of Burnham products or repair part s, please contact Burnham Customer Service at (717) 481-8400 or Fax (717) 481-8408. ...

  • Burnham 81441001R8-3/06 - page 16

    Limited W arranty – Except as provided below with respect to products or parts not manufactured by U.S. Boiler Co., Inc. U.S. Boiler Co., Inc. warrants to the original owner at the original installation site that products manufactured by U.S. Boile r Co., Inc. comply , at the time of manufacture, with recognized Hydronics industry regulatory agen ...

Fabricant Burnham Catégorie Heating System

Les documents que nous recevons du fabricant de l'appareilBurnham 81441001R8-3/06 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Burnham
- manuels d’utilisations 81441001R8-3/06
- fiches produit Burnham
- dépliants
- ou étiquettes-énergie Burnham 81441001R8-3/06
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Burnham 81441001R8-3/06.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Burnham 81441001R8-3/06, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Burnham 81441001R8-3/06. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Burnham 81441001R8-3/06.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Burnham 81441001R8-3/06, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Burnham 81441001R8-3/06 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Burnham 81441001R8-3/06.

Le manuel d’utilisation complet Burnham, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Burnham 81441001R8-3/06 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Burnham 81441001R8-3/06, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBurnham 81441001R8-3/06 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Burnham 81441001R8-3/06 - qui devraient nous aider dans les premières étapes lors de l'utilisation Burnham 81441001R8-3/06
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Burnham 81441001R8-3/06
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Burnham 81441001R8-3/06 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Burnham 81441001R8-3/06?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Burnham 81441001R8-3/06, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Burnham 81441001R8-3/06 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)