Инструкция обслуживания Burnham 81441001R8-3/06

16 страниц 1.69 mb
Скачать

Перейти на страницу of 16

Summary
  • Burnham 81441001R8-3/06 - page 1

    81441001R8-3/06 Price - $2.00 R O F L A U N A M N O I T A L L A T S N I M A H N R U B A R - E S A BY ® PA G E 2 I=B=R RA TINGS 4 ASSEMBL Y CHAR T 5 SYSTEM TYPES 6 SERIES L OOP SYSTEMS 7 SERIES L OOP DESIGN 8 INST ALLA TION DET AILS 9 INST ALLA TION INSTR UCTIONS 10 ASSEMBL Y INSTR UCTIONS 14 SPECIAL APPLICA TIONS 16 W ARRANTY T ABLE OF CONTENTS r ...

  • Burnham 81441001R8-3/06 - page 2

    2 For Ratings at the following temperatures, multiply the 150° rating by the multiplier of the desired temperature. No. 9A Base-Ray ® I=B=R Ratings – Steam and Hot W ater ( 500 LBS/HR Flow Rate **) I=B=R Ratings are determined from tests made in accordance with the I=B=R Testing and Rating Code for Baseboard Type of Radiation, including an allo ...

  • Burnham 81441001R8-3/06 - page 3

    3 For Ratings at the following temperatures, multiply the 150° rating by the multiplier of the desired temperature. T emperature – Multiplier 150° - 1.0 140° - .82 No. 9A Base-Ray ® I=B=R Ratings – Steam and Hot W ater ( 2000 LBS/HR Flow Rate **) n i h t g n e L * t e e F l a e n i L m a e t S g n i t a R t e e F e r a u q S m a e t S g n i ...

  • Burnham 81441001R8-3/06 - page 4

    4 Dimensions and Speci ¿ cations BASE-RA Y T APPINGS- T apped 3/4" top and bot- tom of end sections. A 3/4" x 1/8" vent bushing is furnished with each Base-Ray Assembly . Only one air vent location need be used. Copper tubing is not recommended for steam appli- cations due to high heat loss through the tubing and thermal expansion n ...

  • Burnham 81441001R8-3/06 - page 5

    5 BASE-RA Y ® HYDRONICS T ypes of Systems Hydronic Heating Systems are classi ¿ ed according to the pip- ing arrangement and heating medium employed. BASE-RA Y is very versatile in that it may be used in almost all types of systems as noted below: 1. Series Loop Forced Circulation Hot W ater 2. One-Pipe Forced Circulation Hot W ater 3. T wo-Pipe ...

  • Burnham 81441001R8-3/06 - page 6

    6 SERIES LOOP SYSTEMS Installation Data This type of installation, in which the BASE-RA Y ® Assem- blies serve as part of the main, is the most economical way BASE-RA Y can be installed. Substantial savings in labor and material are realized in that one-pipe ¿ ttings, shut-of f valves, balancing cocks and additional piping are eliminated. Quality ...

  • Burnham 81441001R8-3/06 - page 7

    7 T o Design Series-Loop Base-Ray ® Installation – 1. Calculate the Heat Loss of each room using the procedure outlined in the I=B=R Heat Loss Calculation Guide No. H-21 or the ASHRAE Guide. 2. Using 210°F as design water temperature and 500 lbs/hr . as À ow rate, select length of BASE-RA Y Assembly for each room to produce desired output. (De ...

  • Burnham 81441001R8-3/06 - page 8

    8 Installation Details A BASE-RA Y ® heating system is extremely easy to install – no other heating system requires less labor . The same installa- tion practices that are used in an ordinary radiator system are followed. Use conventional methods in selecting boiler and pipe sizes, including mains, risers and branches. Supply and return connecti ...

  • Burnham 81441001R8-3/06 - page 9

    9 INST ALLA TION INSTRUCTIONS 1. W all Preparation: T o prevent excessive heat loss through the walls in back of BASE-RA Y ® , it is recommended that the stud space behind the Assemblies be insulated to a height of at least 12” above the À oor with 4” mineral wool batts (blanket or loose insulation may also be used) or other approved insulati ...

  • Burnham 81441001R8-3/06 - page 10

    10 5. Assembling BASE-RA Y ® BASE-RA Y is shipped assembled in lengths up to six (6) lineal feet – longer assemblies are shipped in two or more sub-assemblies for assembly on the job (see BASE-RA Y Assembly chart, page 4). One man can join tow sub- assemblies together in a matter of minutes providing he has a BASE-RA Y Assembly Clamp (available ...

  • Burnham 81441001R8-3/06 - page 11

    11 Stand Assemblies upright, place in position and fasten to the walls with T op Center Supports using the number shown in the table above. Insert T op Center Supports in Air Outlet opening of Sections opposite studs (stud locations determined in step 1). Use wood screw furnished with T op Center Support and screw into stud until tight, the longer ...

  • Burnham 81441001R8-3/06 - page 12

    12 8. Installation of Corner Plates INVER TED CORNER PLA TES – for inside corners – furnished in two types, 4-5/8” standard plate is used when Assemblies on adjoining walls extend to within 4-3/8” of the corner . If this distance is greater than 4-3/8” but less than 10-3/8”, the 10-5/8” plate is used. Extended Plate may be cut to desi ...

  • Burnham 81441001R8-3/06 - page 13

    13 ADJUST ABLE END CAPS & FILLER PIECES – Adjustable End Caps are available in both left-hand and right-hand patterns and are used in the same loca- tions as the standard end caps except the 9” length of the adjustable end caps makes it possible to ¿ ll in spaces of up to 7-1/2”. A knockout is also available in the ends for piping. Fille ...

  • Burnham 81441001R8-3/06 - page 14

    14 SPECIAL APPLICA TIONS BASE-RA Y ® INST ALLED ON THREE W ALLS OF ROOM – When BASE-RA Y is installed on three walls, expansion noises are sometimes created by the middle assembly when rigid piping is used to connect all three assemblies together . Flexibility can be gained by connecting two of the adjoining assemblies with a À exible connector ...

  • Burnham 81441001R8-3/06 - page 15

    15 All Base-Ray® repair parts may be obtained through your local Burnham Wholesale Distributor . Should you require assistance in locating a Burnham Distributor in your area, or have questions regarding the availability of Burnham products or repair part s, please contact Burnham Customer Service at (717) 481-8400 or Fax (717) 481-8408. ...

  • Burnham 81441001R8-3/06 - page 16

    Limited W arranty – Except as provided below with respect to products or parts not manufactured by U.S. Boiler Co., Inc. U.S. Boiler Co., Inc. warrants to the original owner at the original installation site that products manufactured by U.S. Boile r Co., Inc. comply , at the time of manufacture, with recognized Hydronics industry regulatory agen ...

Производитель Burnham Категория Heating System

Документы, которые мы получаем от производителя устройства Burnham 81441001R8-3/06 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Burnham
- инструкции обслуживания 81441001R8-3/06
- паспорта изделия Burnham
- информационные брошюры
- энергетические этикетки Burnham 81441001R8-3/06
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Burnham 81441001R8-3/06.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Burnham 81441001R8-3/06, инструкции обслуживания, короткие инструкции или инструкции пользователя Burnham 81441001R8-3/06. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Burnham 81441001R8-3/06.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Burnham 81441001R8-3/06, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Burnham 81441001R8-3/06 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Burnham 81441001R8-3/06.

Полная инструкция обслуживания Burnham, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Burnham 81441001R8-3/06 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Burnham 81441001R8-3/06, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Burnham 81441001R8-3/06, которое найдем в данном документе
3. Советы по использованию основных функций устройства Burnham 81441001R8-3/06 - которые должны облегчить нам первые шаги во время использования Burnham 81441001R8-3/06
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Burnham 81441001R8-3/06
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Burnham 81441001R8-3/06 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Burnham 81441001R8-3/06?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Burnham 81441001R8-3/06, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Burnham 81441001R8-3/06 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)