  • Empire Comfort Systems CIVF-25-2 - page 1

    Page 1 R-3451 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL CAST IRON UNVENTED ROOM HEA TER MODEL CIVF-25-2 EFFECTIVE DA TE JUL Y , 2000 This is an unvented gas-fir ed heater . It uses air (oxygen) fr om the r oom in which it is installed. Pr ovisions for adequate com- bustion and ventilation air must be pr o- vided. Refer to page 4. W ARNING ...

  • Empire Comfort Systems CIVF-25-2 - page 2

    Page 2 R-3451 Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of an unvented room heater. This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of ...

  • Empire Comfort Systems CIVF-25-2 - page 3

    Page 3 R-3451 Some people cannot smell well. Some people cannot smell the odor of the chemical stench put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Some- times other odors in the area ...

  • Empire Comfort Systems CIVF-25-2 - page 4

    Page 4 R-3451 Provisions for Adequate Combustion and Ventilation Air This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. The National Fuel Gas Code, ANSI Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet pe ...

  • Empire Comfort Systems CIVF-25-2 - page 5

    Page 5 R-3451 Figure 1 Figure 2 Figure 3 ...

  • Empire Comfort Systems CIVF-25-2 - page 6

    Page 6 R-3451 Appliance Hardware Package (Figure 4) Figure 4 Appliance Hardware Package Parts List Part Part Quantity Description Number Supplied 1/4-20 x 1" Phillips Head Bolt R-3188 4 1/4-20 x 3/8" Phillips Head Bolt R-3646 16 1/4-20 x 1/2" Leveling Bolt R-3747 4 No. 10 x 1/2" R-2737 6 Hex Washer Head Screw 1/4-20 Washer Head ...

  • Empire Comfort Systems CIVF-25-2 - page 7

    Page 7 R-3451 Figure 6 10. Attach the (4) 1-1/4" x 1/2" retaining tabs to the casing front with (4) 3/8" bolts. The retaining tabs should be positioned downward, from the casing front, top to the casing front, bottom. 11. Refer to Figure 8, attach casing front to outer casing by using the (4) retaining tabs on the casing front. The ( ...

  • Empire Comfort Systems CIVF-25-2 - page 8

    Page 8 R-3451 Figure 8 Figure 9 Stone Inlay Replacement of Standard Grille Top Whenever the standard grille top is replaced with a stone inlay you must install the top shield and heat shield, which are provided with the stone inlay. Installation of Optional Stone Inlay 1. Remove left grille, center grille and right grille from casing top. 2. Remove ...

  • Empire Comfort Systems CIVF-25-2 - page 9

    Page 9 R-3451 3. Place the casing top on a non-abrasive surface in order to protect the porcelain finish. The exterior of the casing top should be facing the non-abrasive surface. 4. Attach 11 5/8" x 11 5/8" top shield to the interior of the casing top with (1) 3/8" bolt provided in hardware package. 5. Locate the (4) screw holes on ...

  • Empire Comfort Systems CIVF-25-2 - page 10

    Page 10 R-3451 2. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). 3. The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing o ...

  • Empire Comfort Systems CIVF-25-2 - page 11

    Page 11 R-3451 Main Burner Flame Pattern (Figure 15 and Figure 16) Figure 15 shows a correct main burner flame pattern. Figure 16 shows an incorrect main burner flame pattern. Correct Main Burner Flame Figure 15 Incorrect Main Burner Flame Figure 16 If main burner flame pattern is incorrect, as shown in Figure 16 • See Troubleshooting, page 15. C ...

  • Empire Comfort Systems CIVF-25-2 - page 12

    Page 12 R-3451 Wiring of ON/OFF/REMOTE Switch with 750 Millivolt Wall Thermostat Accessory and Another Accessory Connect the green and red, stripped and bare, wires on the ON/OFF/ REMOTE switch wire harness to the 750 millivolt wall thermostat AND to the remote receiver that is a component in the FRBC-1, FREC-1 OR to the FWS-1, wall switch. 1. Conn ...

  • Empire Comfort Systems CIVF-25-2 - page 13

    Page 13 R-3451 Figure 19 Operating Guidelines Before operating this heater, please review the safety warnings pages at the beginning of this manual and those precautions and warnings listed below. 1. Know what type of ignition system this model has (standing pilot) and follow the applicable SAFETY and LIGHTING instructions. 2. Check to ensure there ...

  • Empire Comfort Systems CIVF-25-2 - page 14

    Page 14 R-3451 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all a ...

  • Empire Comfort Systems CIVF-25-2 - page 15

    Page 15 R-3451 TROUBLE-SHOOTING SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. 1. When ignitor butt ...

  • Empire Comfort Systems CIVF-25-2 - page 16

    Page 16 R-3451 Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 How To Order Repair Parts ... Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer . ...

  • Empire Comfort Systems CIVF-25-2 - page 17

    Page 17 R-3451 Index Part No. Number Description Index Part No. Number Description PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. Parts List for CIVF-25 Firebox 1 *CI-006 WINDOW RETAINING TAB 2 R-3948 WINDOW (BLACK PAINT) 2 R-3688 WINDOW (BLACK ENAMEL) 2 R-3696 WINDOW (SAND ENAMEL) 2 R-3704 ...

  • Empire Comfort Systems CIVF-25-2 - page 18

    Page 18 R-3451 ...

  • Empire Comfort Systems CIVF-25-2 - page 19

    Page 19 R-3451 OPTIONAL BLOWER CIB-2 Unvented Room Heater CIVF-25 Installing Optional CIB-2 Blower 1. Loosen, but do not remove, (4) hex-head screws located on the exterior, bottom of the appliance. 2. Position the blower assembly at the rear of the appliance. The blower assembly has (4) keyholes for attachment to the exterior, bottom of the applia ...

  • Empire Comfort Systems CIVF-25-2 - page 20

    Page 20 R-3451 Cleaning The blower wheel will collect lint and could require cleaning once a year. If the air output decreases or the noise level increases, it indicates a dirty wheel. Blower Motor The blower motor does not have oiling holes. Do not attempt to oil blower motor. PARTS LIST Index Part No. No. Description 1 R-1454 Brass Bushing (4 Req ...

Fabricant Empire Comfort Systems Catégorie Electric Heater

Les documents que nous recevons du fabricant de l'appareilEmpire Comfort Systems CIVF-25-2 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Empire Comfort Systems
- manuels d’utilisations CIVF-25-2
- fiches produit Empire Comfort Systems
- dépliants
- ou étiquettes-énergie Empire Comfort Systems CIVF-25-2
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Empire Comfort Systems CIVF-25-2.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Empire Comfort Systems CIVF-25-2, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Empire Comfort Systems CIVF-25-2. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Empire Comfort Systems CIVF-25-2.

Manuel d’utilisation complet de l’appareil Empire Comfort Systems CIVF-25-2, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Empire Comfort Systems CIVF-25-2 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Empire Comfort Systems CIVF-25-2.

Le manuel d’utilisation complet Empire Comfort Systems, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Empire Comfort Systems CIVF-25-2 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Empire Comfort Systems CIVF-25-2, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lEmpire Comfort Systems CIVF-25-2 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Empire Comfort Systems CIVF-25-2 - qui devraient nous aider dans les premières étapes lors de l'utilisation Empire Comfort Systems CIVF-25-2
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Empire Comfort Systems CIVF-25-2
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Empire Comfort Systems CIVF-25-2 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Empire Comfort Systems CIVF-25-2?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Empire Comfort Systems CIVF-25-2, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Empire Comfort Systems CIVF-25-2 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)