    Page 1 R-3451 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL CAST IRON UNVENTED ROOM HEA TER MODEL CIVF-25-2 EFFECTIVE DA TE JUL Y , 2000 This is an unvented gas-fir ed heater . It uses air (oxygen) fr om the r oom in which it is installed. Pr ovisions for adequate com- bustion and ventilation air must be pr o- vided. Refer to page 4. W ARNING ...

  • Empire Comfort Systems CIVF-25-2 - page 2

    Page 2 R-3451 Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of an unvented room heater. This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by state or local codes. *Aftermarket: Completion of ...

  • Empire Comfort Systems CIVF-25-2 - page 3

    Page 3 R-3451 Some people cannot smell well. Some people cannot smell the odor of the chemical stench put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Some- times other odors in the area ...

  • Empire Comfort Systems CIVF-25-2 - page 4

    Page 4 R-3451 Provisions for Adequate Combustion and Ventilation Air This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. The National Fuel Gas Code, ANSI Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet pe ...

  • Empire Comfort Systems CIVF-25-2 - page 5

    Page 5 R-3451 Figure 1 Figure 2 Figure 3 ...

  • Empire Comfort Systems CIVF-25-2 - page 6

    Page 6 R-3451 Appliance Hardware Package (Figure 4) Figure 4 Appliance Hardware Package Parts List Part Part Quantity Description Number Supplied 1/4-20 x 1" Phillips Head Bolt R-3188 4 1/4-20 x 3/8" Phillips Head Bolt R-3646 16 1/4-20 x 1/2" Leveling Bolt R-3747 4 No. 10 x 1/2" R-2737 6 Hex Washer Head Screw 1/4-20 Washer Head ...

  • Empire Comfort Systems CIVF-25-2 - page 7

    Page 7 R-3451 Figure 6 10. Attach the (4) 1-1/4" x 1/2" retaining tabs to the casing front with (4) 3/8" bolts. The retaining tabs should be positioned downward, from the casing front, top to the casing front, bottom. 11. Refer to Figure 8, attach casing front to outer casing by using the (4) retaining tabs on the casing front. The ( ...

  • Empire Comfort Systems CIVF-25-2 - page 8

    Page 8 R-3451 Figure 8 Figure 9 Stone Inlay Replacement of Standard Grille Top Whenever the standard grille top is replaced with a stone inlay you must install the top shield and heat shield, which are provided with the stone inlay. Installation of Optional Stone Inlay 1. Remove left grille, center grille and right grille from casing top. 2. Remove ...

  • Empire Comfort Systems CIVF-25-2 - page 9

    Page 9 R-3451 3. Place the casing top on a non-abrasive surface in order to protect the porcelain finish. The exterior of the casing top should be facing the non-abrasive surface. 4. Attach 11 5/8" x 11 5/8" top shield to the interior of the casing top with (1) 3/8" bolt provided in hardware package. 5. Locate the (4) screw holes on ...

  • Empire Comfort Systems CIVF-25-2 - page 10

    Page 10 R-3451 2. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). 3. The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing o ...

  • Empire Comfort Systems CIVF-25-2 - page 11

    Page 11 R-3451 Main Burner Flame Pattern (Figure 15 and Figure 16) Figure 15 shows a correct main burner flame pattern. Figure 16 shows an incorrect main burner flame pattern. Correct Main Burner Flame Figure 15 Incorrect Main Burner Flame Figure 16 If main burner flame pattern is incorrect, as shown in Figure 16 • See Troubleshooting, page 15. C ...

  • Empire Comfort Systems CIVF-25-2 - page 12

    Page 12 R-3451 Wiring of ON/OFF/REMOTE Switch with 750 Millivolt Wall Thermostat Accessory and Another Accessory Connect the green and red, stripped and bare, wires on the ON/OFF/ REMOTE switch wire harness to the 750 millivolt wall thermostat AND to the remote receiver that is a component in the FRBC-1, FREC-1 OR to the FWS-1, wall switch. 1. Conn ...

  • Empire Comfort Systems CIVF-25-2 - page 13

    Page 13 R-3451 Figure 19 Operating Guidelines Before operating this heater, please review the safety warnings pages at the beginning of this manual and those precautions and warnings listed below. 1. Know what type of ignition system this model has (standing pilot) and follow the applicable SAFETY and LIGHTING instructions. 2. Check to ensure there ...

  • Empire Comfort Systems CIVF-25-2 - page 14

    Page 14 R-3451 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all a ...

  • Empire Comfort Systems CIVF-25-2 - page 15

    Page 15 R-3451 TROUBLE-SHOOTING SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. 1. When ignitor butt ...

  • Empire Comfort Systems CIVF-25-2 - page 16

    Page 16 R-3451 Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 How To Order Repair Parts ... Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer . ...

  • Empire Comfort Systems CIVF-25-2 - page 17

    Page 17 R-3451 Index Part No. Number Description Index Part No. Number Description PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. Parts List for CIVF-25 Firebox 1 *CI-006 WINDOW RETAINING TAB 2 R-3948 WINDOW (BLACK PAINT) 2 R-3688 WINDOW (BLACK ENAMEL) 2 R-3696 WINDOW (SAND ENAMEL) 2 R-3704 ...

  • Empire Comfort Systems CIVF-25-2 - page 18

    Page 18 R-3451 ...

  • Empire Comfort Systems CIVF-25-2 - page 19

    Page 19 R-3451 OPTIONAL BLOWER CIB-2 Unvented Room Heater CIVF-25 Installing Optional CIB-2 Blower 1. Loosen, but do not remove, (4) hex-head screws located on the exterior, bottom of the appliance. 2. Position the blower assembly at the rear of the appliance. The blower assembly has (4) keyholes for attachment to the exterior, bottom of the applia ...

  • Empire Comfort Systems CIVF-25-2 - page 20

    Page 20 R-3451 Cleaning The blower wheel will collect lint and could require cleaning once a year. If the air output decreases or the noise level increases, it indicates a dirty wheel. Blower Motor The blower motor does not have oiling holes. Do not attempt to oil blower motor. PARTS LIST Index Part No. No. Description 1 R-1454 Brass Bushing (4 Req ...

Производитель Empire Comfort Systems Категория Electric Heater

Документы, которые мы получаем от производителя устройства Empire Comfort Systems CIVF-25-2 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Empire Comfort Systems
- инструкции обслуживания CIVF-25-2
- паспорта изделия Empire Comfort Systems
- информационные брошюры
- энергетические этикетки Empire Comfort Systems CIVF-25-2
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Empire Comfort Systems CIVF-25-2.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Empire Comfort Systems CIVF-25-2, инструкции обслуживания, короткие инструкции или инструкции пользователя Empire Comfort Systems CIVF-25-2. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Empire Comfort Systems CIVF-25-2.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Empire Comfort Systems CIVF-25-2, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Empire Comfort Systems CIVF-25-2 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Empire Comfort Systems CIVF-25-2.

Полная инструкция обслуживания Empire Comfort Systems, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Empire Comfort Systems CIVF-25-2 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Empire Comfort Systems CIVF-25-2, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Empire Comfort Systems CIVF-25-2, которое найдем в данном документе
3. Советы по использованию основных функций устройства Empire Comfort Systems CIVF-25-2 - которые должны облегчить нам первые шаги во время использования Empire Comfort Systems CIVF-25-2
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Empire Comfort Systems CIVF-25-2
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Empire Comfort Systems CIVF-25-2 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Empire Comfort Systems CIVF-25-2?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Empire Comfort Systems CIVF-25-2, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Empire Comfort Systems CIVF-25-2 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)