    GENERAL These completely assembled blower units are manufac- tured under ISO 9002 Quality System Certification and include a well-insulated cabinet, a DX cooling coil with copper tubes and aluminum fins, an expansion valve, a distributor , throwaway filters, a centrifugal blower , a blower motor , a blower motor contactor , an adjustable belt drive ...

  • York K4EU120A50A - page 2

    2 Unitary Products Group 550.39-N4YI T ABLE OF CONTENTS General ................................................................................ 1 Reference ............................................................................ 1 Inspection ............................................................................ 1 Nomenclature ........... ...

  • York K4EU120A50A - page 3

    carrier's agent should be made in writing. See Local Dis - tributor for additional information. LIMIT ATIONS These units must be installed in accordance with applicable na - tional, local and municipal safety codes. If components are to be added to a unit to meet local codes, they are to be installed at the dealer's and/or the customer&ap ...

  • York K4EU120A50A - page 4

    CLEARANCES The clearances listed on the unit dimension drawing (Figure 9) are required for the proper service and opera - tion of the unit. RIGGING AND HANDLING Be careful when moving the unit. Do not remove any packaging until the unit is near its final location. The packaging consists of a bottom wooden skid that can be lifted with a fork truck f ...

  • York K4EU120A50A - page 5

    REFRIGERANT MAINS Many service problems can be avoided by taking adequate pre- cautions to provide an internally clean and dry system, and by us- ing procedures and materials that conform with established standards. Hard drawn copper tubing should be used where no apprecia - ble amount of bending around pipes or other obstructions in necessary . Us ...

  • York K4EU120A50A - page 6

    Before brazing the refrigerant lines to these connections, remove the short panel from the unit frame and slide it (along with the grommets) onto the refrigerant lines. Af - ter the brazed joints have cooled, slide the panel back into place and secure it to the unit frame. NOTE: These units can only be piped from one side of the unit. EXP ANSION V ...

  • York K4EU120A50A - page 7

    3. Using an inclined manometer , determine the pressure drop across a dry evaporator coil. Since the moisture on an evaporator coil may vary greatly , measuring the pressure drop across a wet coil under field conditions would be inac - curate. T o assure a dry coil, the refrigerant system should be de-energized while the test is being run. 4. Knowi ...

  • York K4EU120A50A - page 8

    8 Unitary Products Group 550.39-N4YI KEU090 - SUPPL Y AIR BLOWER PERFORMANCE 1 - (CFM) BLOWER SPEED RPM AIRFLOW ESP 2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (KW) ESP2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (kW 2400 CFM 2700 CFM 3000 CFM 3300 CFM 3600CFM 600 0.35 0.62 0. ...

  • York K4EU120A50A - page 9

    Unitary Products Group 9 550.39-N4YI T ABLE 5 - ACCESSOR Y ST A TIC RESIST ANCE (IWG) ACCESSORY EXTERNAL ST A TIC PRESSURE DROP RESIST ANCE IWG/pA BLOWER CFM/m 3 /s 2400 / 1.1 2700 / 1.3 3000 / 1.4 3300 / 1.6 3600 / 1.7 Electric Heat 10k W 0.01 / 2.5 0.01 / 2.5 0.01/ 2.5 0.02 / 5.0 0.02/ 5.0 16 kW 0.01 / 2.5 0.02 / 5.0 0.02 / 5.0 0.03 / 7.4 0.04/ 1 ...

  • York K4EU120A50A - page 10

    10 Unitary Products Group 550.39-N4YI FIG 9 - UNIT DIMENSIONS AND CLEARANCES Overall dimension of the unit will vary if an electric heater , a supply air plenum or a base is used. This dimension is required for removal of the DX coil. Only 26" is required for normal servicing. If the DX coil has to be removed, this dimension is required to loo ...

  • York K4EU120A50A - page 11

    Unitary Products Group 11 550.39-N4YI MOTOR SPECIFICA - TIONS •1450 RPM •380/415-3-50 •Solid base •56 Frame •Inherently protected Permanently lubricated ball bearings POWER AND CONTROL WIRING Install electrical wiring in accordance with applicable national, local and municipal codes. The unit should be grounded in ac - cordance with these ...

  • York K4EU120A50A - page 12

    Unitary Products Group P .O. Box 1592, Y ork, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in U.S.A Copyright © by Y ork International Corporation 1994. All Rights Reserved. 550.39-N4YI MAINTENANCE FILTERS — The filters must be replaced as often as necessary to assure good air flow and filtering action. Refer to the unit ...

Fabricant York Catégorie Fan

Les documents que nous recevons du fabricant de l'appareilYork K4EU120A50A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques York
- manuels d’utilisations K4EU120A50A
- fiches produit York
- dépliants
- ou étiquettes-énergie York K4EU120A50A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation York K4EU120A50A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation York K4EU120A50A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur York K4EU120A50A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit York K4EU120A50A.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil York K4EU120A50A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser York K4EU120A50A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs York K4EU120A50A.

Le manuel d’utilisation complet York, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel York K4EU120A50A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières York K4EU120A50A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lYork K4EU120A50A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil York K4EU120A50A - qui devraient nous aider dans les premières étapes lors de l'utilisation York K4EU120A50A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de York K4EU120A50A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service York K4EU120A50A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de York K4EU120A50A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec York K4EU120A50A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec York K4EU120A50A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)