Manuale per l’uso York K4EU120A50A

12 pagine 0.22 mb
Scarica

Vai alla pagina of 12

Summary
  • York K4EU120A50A - page 1

    GENERAL These completely assembled blower units are manufac- tured under ISO 9002 Quality System Certification and include a well-insulated cabinet, a DX cooling coil with copper tubes and aluminum fins, an expansion valve, a distributor , throwaway filters, a centrifugal blower , a blower motor , a blower motor contactor , an adjustable belt drive ...

  • York K4EU120A50A - page 2

    2 Unitary Products Group 550.39-N4YI T ABLE OF CONTENTS General ................................................................................ 1 Reference ............................................................................ 1 Inspection ............................................................................ 1 Nomenclature ........... ...

  • York K4EU120A50A - page 3

    carrier's agent should be made in writing. See Local Dis - tributor for additional information. LIMIT ATIONS These units must be installed in accordance with applicable na - tional, local and municipal safety codes. If components are to be added to a unit to meet local codes, they are to be installed at the dealer's and/or the customer&ap ...

  • York K4EU120A50A - page 4

    CLEARANCES The clearances listed on the unit dimension drawing (Figure 9) are required for the proper service and opera - tion of the unit. RIGGING AND HANDLING Be careful when moving the unit. Do not remove any packaging until the unit is near its final location. The packaging consists of a bottom wooden skid that can be lifted with a fork truck f ...

  • York K4EU120A50A - page 5

    REFRIGERANT MAINS Many service problems can be avoided by taking adequate pre- cautions to provide an internally clean and dry system, and by us- ing procedures and materials that conform with established standards. Hard drawn copper tubing should be used where no apprecia - ble amount of bending around pipes or other obstructions in necessary . Us ...

  • York K4EU120A50A - page 6

    Before brazing the refrigerant lines to these connections, remove the short panel from the unit frame and slide it (along with the grommets) onto the refrigerant lines. Af - ter the brazed joints have cooled, slide the panel back into place and secure it to the unit frame. NOTE: These units can only be piped from one side of the unit. EXP ANSION V ...

  • York K4EU120A50A - page 7

    3. Using an inclined manometer , determine the pressure drop across a dry evaporator coil. Since the moisture on an evaporator coil may vary greatly , measuring the pressure drop across a wet coil under field conditions would be inac - curate. T o assure a dry coil, the refrigerant system should be de-energized while the test is being run. 4. Knowi ...

  • York K4EU120A50A - page 8

    8 Unitary Products Group 550.39-N4YI KEU090 - SUPPL Y AIR BLOWER PERFORMANCE 1 - (CFM) BLOWER SPEED RPM AIRFLOW ESP 2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (KW) ESP2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (kW 2400 CFM 2700 CFM 3000 CFM 3300 CFM 3600CFM 600 0.35 0.62 0. ...

  • York K4EU120A50A - page 9

    Unitary Products Group 9 550.39-N4YI T ABLE 5 - ACCESSOR Y ST A TIC RESIST ANCE (IWG) ACCESSORY EXTERNAL ST A TIC PRESSURE DROP RESIST ANCE IWG/pA BLOWER CFM/m 3 /s 2400 / 1.1 2700 / 1.3 3000 / 1.4 3300 / 1.6 3600 / 1.7 Electric Heat 10k W 0.01 / 2.5 0.01 / 2.5 0.01/ 2.5 0.02 / 5.0 0.02/ 5.0 16 kW 0.01 / 2.5 0.02 / 5.0 0.02 / 5.0 0.03 / 7.4 0.04/ 1 ...

  • York K4EU120A50A - page 10

    10 Unitary Products Group 550.39-N4YI FIG 9 - UNIT DIMENSIONS AND CLEARANCES Overall dimension of the unit will vary if an electric heater , a supply air plenum or a base is used. This dimension is required for removal of the DX coil. Only 26" is required for normal servicing. If the DX coil has to be removed, this dimension is required to loo ...

  • York K4EU120A50A - page 11

    Unitary Products Group 11 550.39-N4YI MOTOR SPECIFICA - TIONS •1450 RPM •380/415-3-50 •Solid base •56 Frame •Inherently protected Permanently lubricated ball bearings POWER AND CONTROL WIRING Install electrical wiring in accordance with applicable national, local and municipal codes. The unit should be grounded in ac - cordance with these ...

  • York K4EU120A50A - page 12

    Unitary Products Group P .O. Box 1592, Y ork, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in U.S.A Copyright © by Y ork International Corporation 1994. All Rights Reserved. 550.39-N4YI MAINTENANCE FILTERS — The filters must be replaced as often as necessary to assure good air flow and filtering action. Refer to the unit ...

Fabbricante York Categoria Fan

I documenti che otteniamo dal fabbricante del dispositivoYork K4EU120A50A possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici York
- manuali per l’uso K4EU120A50A
- schede prodotto York
- opuscoli
- o etichette energetiche York K4EU120A50A
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso York K4EU120A50A.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione York K4EU120A50A, manuali di manutenzione, brevi manuali o manuali utente York K4EU120A50A. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto York K4EU120A50A.

Manuali per l’uso simili

Manuale completo del dispositivo York K4EU120A50A, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare York K4EU120A50A dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti York K4EU120A50A.

Il manuale per l’uso completo York, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale York K4EU120A50A - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice York K4EU120A50A, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per York K4EU120A50A che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo York K4EU120A50A - che ci dovrebbe aiutare nei primi passi durante l'uso York K4EU120A50A
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del York K4EU120A50A
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio York K4EU120A50A in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su York K4EU120A50A?

Utilizza il modulo sottostante

Se non hai risolto il problema con York K4EU120A50A con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con York K4EU120A50A è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)