    Accor d Series T5/T8 Enhanced Lighting System ...

  • Cooper Lighting Metalux Accord Series - page 2

    1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Visual Perception 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Comparison 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Energy Savings 9 . . . . . . . . . . . . . . . ...

  • Cooper Lighting Metalux Accord Series - page 3

    2 Improve visual perception • The accord TM evenly distributes light, making the space more pleasing to the eye. • Dark spots (cave effect) associated with parabolics are eliminated. Attractive design • Smooth, cur ved surfaces are attractive but subtle. • Soft white frosted acrylic lens fills the space with even illumination. • High refl ...

  • Cooper Lighting Metalux Accord Series - page 4

    Parabolics are designed to direct light into the cut-off zone, while restricting light into the shielded or glare zone. In other words, parabolics deliver light to the work plane and suppress high-angle brightness. Due to the high-angle cutoffs as shown in Figure 1. , parabolics can create areas where light is concentrated and areas where there is ...

  • Cooper Lighting Metalux Accord Series - page 5

    SHIELDED ZONE CUT -OFF ZONE 85˚ 75˚ 65˚ 55˚ Figure 1. Parabolic Light Distribution MINIMIZED SHIELDED ZONE ENHANCED CUT -OFF ZONE 85˚ 75˚ 65˚ 55˚ Figure 2. accord TM Light Distribution Attractive contemporary design • Smooth, cur ved surfaces are attractive but subtle. • Soft white frosted acr ylic lens fills the space with even illumin ...

  • Cooper Lighting Metalux Accord Series - page 6

    accord TM 2 Lamp, T5 accord TM (2) 28W T5 lamps, 18 fixtures step-dim electronic ballast (.95 ballast factor) 63 watts per fixture Watts/Sq.ft. Horizontal Footcandles Vertical Footcandles 0.76 41 25 IES* accord TM maximizes savings Choose either T5 or T8 technology to best meet your lighting needs. With a multitude of lamp and ballast combinations, ...

  • Cooper Lighting Metalux Accord Series - page 7

    T roffer 4 Lamp T ypical 4 lamp troffer (4) 32W T8 lamps, 12 fixtures electronic ballast (.87 ballast factor) 122 watts per fixture Watts/Sq.ft. Horizontal Footcandles Vertical Footcandles 0.98 50 23 IES* accord TM 2 Lamp, T8 accord TM (2) 32W T8 lamps, 12 fixtures electronic ballast (1.20 ballast factor) 77 watts per fixture Watts/Sq.ft. Horizonta ...

  • Cooper Lighting Metalux Accord Series - page 8

    Appearance and performance make accord TM the lighting choice. Energy savings makes accord TM a sound financial decision. The accord TM family of products saves up to 40% energy costs when compared to a standard 3 lamp,18 cell parabolic. The dimming feature reduces energy consumption by another 50%. The accord TM meets and exceeds ASHRAE 90.1 2001 ...

  • Cooper Lighting Metalux Accord Series - page 9

    COST PER kWh Hours of Oper ation $0.06 $0.08 $0.1 0 $0.1 2 $0.1 4 P er Day P er Y ear 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 12 hrs. 4,380 $16.03 $7.88 $21.37 $10.51 $26.72 $13.14 $32.06 $15.76 $37.41 $18.36 18 hrs. 6,570 $24.04 $1 1.82 $32.06 $15.76 $40.07 $19.71 $48.09 $23.65 $56.10 $27.59 24 hrs. 8,760 $32.06 $15.77 $42.74 $ ...

  • Cooper Lighting Metalux Accord Series - page 10

    • 3-13/16" low profile housing Surface Mount av ailable Low profile and quality performance – the surface accord TM is an energy efficient alternative to traditional surface mount fixtures. Designed for areas without a grid-ceiling type system, the accord’ s TM low profile is an ideal retro-fit solution. Sleek yet durable – constructed ...

  • Cooper Lighting Metalux Accord Series - page 11

    Diffuser Options Square Perf Design (SQP) Smooth acrylic diffuser with square perforated insert (2' x 2', 2' x 4' only) Round Perf Design (RPD) Smooth acrylic diffuser with round perforated insert (2' x 2', 2' x 4' only) Smooth Design (standard) Aesthetically Improved Design Precision engineered, accord’ s ...

  • Cooper Lighting Metalux Accord Series - page 12

    accord TM - 1' x 4', T5 accord TM - 1' x 4', T8 Candlepower Angle Along II 45° Across ⊥ 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 AC-128T5 Electronic Ballast (1) F28T5/835 Lamp 260 0 Lumens Spacing criterion: (II) 1 .2 x mounting height, ( ⊥ ) 1 .4 x mounting height Efficiency 87 .4% T est Report: 241P1 13 Inpu ...

  • Cooper Lighting Metalux Accord Series - page 13

    accord TM - 2' x 2', T5 accord TM - 2' x 2', T8 Candlepower Angle Along II 45° Across ⊥ 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 2AC-214T5 Electronic Ballast (2) F14T5/835 Lamps 1350 Lumens Spacing criterion: (II) 1 .2 x mounting height, ( ⊥ ) 1 .4 x mounting height Efficiency 89.4% T est Report: 2A C-214T5.IE ...

  • Cooper Lighting Metalux Accord Series - page 14

    T5 Ordering Information SAMPLE NUMBER: 2AC-228T5-UNV-L5841-EBT1NDIM-U Number of Lamps (Not included) 1 =1 Lamp (1' x 4' only) 2 =2 Lamp (2' x 2', 2' x 4' only) W attage (Length) 28T5 =28W T5 (48") 54T5 =54W T5HO (48") 14T5 =14W T5 (24") 24T5 =24W T5HO (24") BX40 =40W Compact Fluorescent (24 ") ...

  • Cooper Lighting Metalux Accord Series - page 15

    • The accord TM can provide up to 40% energy savings when compared to a 3 lamp, 18 cell, T8 parabolic. • The accord TM also exceeds mandated energy regulations such as California’ s Titl e 24 and ASHRAE 90.1 2001. • Step dimming can increase energy s av ings by as much as 50%. Simple Maintenance Energy Savings • The ballast is accessible ...

  • Cooper Lighting Metalux Accord Series - page 16

    Printed in USA ADF080670 Cooper Industries, Ltd. 600 T ravis, Ste. 5800 Houston, TX 77002-1001 P: 713-209-8400 www .cooperindustries.com Cooper Lighting and Metalux logos are valuable trademarks of Cooper Industries in the United States and other countries. Y ou are not permitted to use the Cooper T rademarks without the prior written consent of Co ...

Fabricant Cooper Lighting Catégorie Indoor Furnishings

Les documents que nous recevons du fabricant de l'appareilCooper Lighting Metalux Accord Series peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Cooper Lighting
- manuels d’utilisations Metalux Accord Series
- fiches produit Cooper Lighting
- dépliants
- ou étiquettes-énergie Cooper Lighting Metalux Accord Series
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Cooper Lighting Metalux Accord Series.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Cooper Lighting Metalux Accord Series, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Cooper Lighting Metalux Accord Series. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Cooper Lighting Metalux Accord Series.

Manuel d’utilisation complet de l’appareil Cooper Lighting Metalux Accord Series, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Cooper Lighting Metalux Accord Series par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Cooper Lighting Metalux Accord Series.

Le manuel d’utilisation complet Cooper Lighting, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Cooper Lighting Metalux Accord Series - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Cooper Lighting Metalux Accord Series, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCooper Lighting Metalux Accord Series qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Cooper Lighting Metalux Accord Series - qui devraient nous aider dans les premières étapes lors de l'utilisation Cooper Lighting Metalux Accord Series
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Cooper Lighting Metalux Accord Series
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Cooper Lighting Metalux Accord Series dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Cooper Lighting Metalux Accord Series?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Cooper Lighting Metalux Accord Series, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Cooper Lighting Metalux Accord Series il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)