    Accor d Series T5/T8 Enhanced Lighting System ...

  • Cooper Lighting Metalux Accord Series - page 2

    1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Visual Perception 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Comparison 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Energy Savings 9 . . . . . . . . . . . . . . . ...

  • Cooper Lighting Metalux Accord Series - page 3

    2 Improve visual perception • The accord TM evenly distributes light, making the space more pleasing to the eye. • Dark spots (cave effect) associated with parabolics are eliminated. Attractive design • Smooth, cur ved surfaces are attractive but subtle. • Soft white frosted acrylic lens fills the space with even illumination. • High refl ...

  • Cooper Lighting Metalux Accord Series - page 4

    Parabolics are designed to direct light into the cut-off zone, while restricting light into the shielded or glare zone. In other words, parabolics deliver light to the work plane and suppress high-angle brightness. Due to the high-angle cutoffs as shown in Figure 1. , parabolics can create areas where light is concentrated and areas where there is ...

  • Cooper Lighting Metalux Accord Series - page 5

    SHIELDED ZONE CUT -OFF ZONE 85˚ 75˚ 65˚ 55˚ Figure 1. Parabolic Light Distribution MINIMIZED SHIELDED ZONE ENHANCED CUT -OFF ZONE 85˚ 75˚ 65˚ 55˚ Figure 2. accord TM Light Distribution Attractive contemporary design • Smooth, cur ved surfaces are attractive but subtle. • Soft white frosted acr ylic lens fills the space with even illumin ...

  • Cooper Lighting Metalux Accord Series - page 6

    accord TM 2 Lamp, T5 accord TM (2) 28W T5 lamps, 18 fixtures step-dim electronic ballast (.95 ballast factor) 63 watts per fixture Watts/Sq.ft. Horizontal Footcandles Vertical Footcandles 0.76 41 25 IES* accord TM maximizes savings Choose either T5 or T8 technology to best meet your lighting needs. With a multitude of lamp and ballast combinations, ...

  • Cooper Lighting Metalux Accord Series - page 7

    T roffer 4 Lamp T ypical 4 lamp troffer (4) 32W T8 lamps, 12 fixtures electronic ballast (.87 ballast factor) 122 watts per fixture Watts/Sq.ft. Horizontal Footcandles Vertical Footcandles 0.98 50 23 IES* accord TM 2 Lamp, T8 accord TM (2) 32W T8 lamps, 12 fixtures electronic ballast (1.20 ballast factor) 77 watts per fixture Watts/Sq.ft. Horizonta ...

  • Cooper Lighting Metalux Accord Series - page 8

    Appearance and performance make accord TM the lighting choice. Energy savings makes accord TM a sound financial decision. The accord TM family of products saves up to 40% energy costs when compared to a standard 3 lamp,18 cell parabolic. The dimming feature reduces energy consumption by another 50%. The accord TM meets and exceeds ASHRAE 90.1 2001 ...

  • Cooper Lighting Metalux Accord Series - page 9

    COST PER kWh Hours of Oper ation $0.06 $0.08 $0.1 0 $0.1 2 $0.1 4 P er Day P er Y ear 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 4L T8 3L T8 12 hrs. 4,380 $16.03 $7.88 $21.37 $10.51 $26.72 $13.14 $32.06 $15.76 $37.41 $18.36 18 hrs. 6,570 $24.04 $1 1.82 $32.06 $15.76 $40.07 $19.71 $48.09 $23.65 $56.10 $27.59 24 hrs. 8,760 $32.06 $15.77 $42.74 $ ...

  • Cooper Lighting Metalux Accord Series - page 10

    • 3-13/16" low profile housing Surface Mount av ailable Low profile and quality performance – the surface accord TM is an energy efficient alternative to traditional surface mount fixtures. Designed for areas without a grid-ceiling type system, the accord’ s TM low profile is an ideal retro-fit solution. Sleek yet durable – constructed ...

  • Cooper Lighting Metalux Accord Series - page 11

    Diffuser Options Square Perf Design (SQP) Smooth acrylic diffuser with square perforated insert (2' x 2', 2' x 4' only) Round Perf Design (RPD) Smooth acrylic diffuser with round perforated insert (2' x 2', 2' x 4' only) Smooth Design (standard) Aesthetically Improved Design Precision engineered, accord’ s ...

  • Cooper Lighting Metalux Accord Series - page 12

    accord TM - 1' x 4', T5 accord TM - 1' x 4', T8 Candlepower Angle Along II 45° Across ⊥ 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 AC-128T5 Electronic Ballast (1) F28T5/835 Lamp 260 0 Lumens Spacing criterion: (II) 1 .2 x mounting height, ( ⊥ ) 1 .4 x mounting height Efficiency 87 .4% T est Report: 241P1 13 Inpu ...

  • Cooper Lighting Metalux Accord Series - page 13

    accord TM - 2' x 2', T5 accord TM - 2' x 2', T8 Candlepower Angle Along II 45° Across ⊥ 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 2AC-214T5 Electronic Ballast (2) F14T5/835 Lamps 1350 Lumens Spacing criterion: (II) 1 .2 x mounting height, ( ⊥ ) 1 .4 x mounting height Efficiency 89.4% T est Report: 2A C-214T5.IE ...

  • Cooper Lighting Metalux Accord Series - page 14

    T5 Ordering Information SAMPLE NUMBER: 2AC-228T5-UNV-L5841-EBT1NDIM-U Number of Lamps (Not included) 1 =1 Lamp (1' x 4' only) 2 =2 Lamp (2' x 2', 2' x 4' only) W attage (Length) 28T5 =28W T5 (48") 54T5 =54W T5HO (48") 14T5 =14W T5 (24") 24T5 =24W T5HO (24") BX40 =40W Compact Fluorescent (24 ") ...

  • Cooper Lighting Metalux Accord Series - page 15

    • The accord TM can provide up to 40% energy savings when compared to a 3 lamp, 18 cell, T8 parabolic. • The accord TM also exceeds mandated energy regulations such as California’ s Titl e 24 and ASHRAE 90.1 2001. • Step dimming can increase energy s av ings by as much as 50%. Simple Maintenance Energy Savings • The ballast is accessible ...

  • Cooper Lighting Metalux Accord Series - page 16

    Printed in USA ADF080670 Cooper Industries, Ltd. 600 T ravis, Ste. 5800 Houston, TX 77002-1001 P: 713-209-8400 www .cooperindustries.com Cooper Lighting and Metalux logos are valuable trademarks of Cooper Industries in the United States and other countries. Y ou are not permitted to use the Cooper T rademarks without the prior written consent of Co ...

Fabbricante Cooper Lighting Categoria Indoor Furnishings

I documenti che otteniamo dal fabbricante del dispositivoCooper Lighting Metalux Accord Series possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Cooper Lighting
- manuali per l’uso Metalux Accord Series
- schede prodotto Cooper Lighting
- opuscoli
- o etichette energetiche Cooper Lighting Metalux Accord Series
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Cooper Lighting Metalux Accord Series.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Cooper Lighting Metalux Accord Series, manuali di manutenzione, brevi manuali o manuali utente Cooper Lighting Metalux Accord Series. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Cooper Lighting Metalux Accord Series.

Manuali per l’uso simili

Manuale completo del dispositivo Cooper Lighting Metalux Accord Series, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Cooper Lighting Metalux Accord Series dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Cooper Lighting Metalux Accord Series.

Il manuale per l’uso completo Cooper Lighting, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Cooper Lighting Metalux Accord Series - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Cooper Lighting Metalux Accord Series, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Cooper Lighting Metalux Accord Series che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Cooper Lighting Metalux Accord Series - che ci dovrebbe aiutare nei primi passi durante l'uso Cooper Lighting Metalux Accord Series
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Cooper Lighting Metalux Accord Series
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Cooper Lighting Metalux Accord Series in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Cooper Lighting Metalux Accord Series?

Utilizza il modulo sottostante

Se non hai risolto il problema con Cooper Lighting Metalux Accord Series con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Cooper Lighting Metalux Accord Series è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)