  • York MV - page 1

    TECHNICAL GUIDE MODELS: MV MODULAR V ARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEA T PUMP 1200 - 200 0 CFM BLOWERS 3 - 5 T ON COILS OPTIONAL 1 & 3 φ ELECTRIC HEA TERS Due to conti nu ous prod uct improvem en t, specifica tion s subject to change withou t notice. Visit us on the web at www. york.com Additional rat ing i ...

  • York MV - page 2

    255427-YTG-F-1006 2 Unitary Products Group DIMENSIONS - (BLOWER WITH MC COILS) NOTE: Power wiring may be brought into the unit through one of the kn ockouts in either the top or the left side panel. Multiple knockouts are provided to accommodate all of the electric heat and transformer accessorie s that are availabl e. Use the knock- outs that prov ...

  • York MV - page 3

    255427-YTG-F-1006 Unitary Products Group 3 COOLING CAP ACITY - COIL ONL Y Blower Model Coil Model Rated CFM Entering Air ° F (Dry / Wet Bulb) MBH @ Evaporator T emperature and Corresponding Pressure °F / PSIG 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 Multi-Position - Upflow / Downflow / Horizont al MV12B MC30B**H 1025 85 / 72 41.5 37.8 33.7 29.5 80 ...

  • York MV - page 4

    255427-YTG-F-1006 4 Unitary Products Group PHYSICAL & ELECTRICAL DA T A Model MV12B MV12D MV16C MV20D Blower - Diameter x Width 10 x 7 10 x 10 10 x 10 10 x 10 Motor HP 1/2 1/2 3/4 1 Nominal RPM 1200 1200 1200 1200 V oltage 208/230 Amps Full Load (230) 4.3 4.3 5.0 7.0 Filter T ype DISPOSABLE OR PERMANENT Size 16 x 20 x 1 22 x 20 x 1 20 x 20 x 1 ...

  • York MV - page 5

    255427-YTG-F-1006 Unitary Products Group 5 * May be 0 (no breaker) or 1 (with breaker). ELECTRICAL DA T A - 208/230-1-60 Model Heater Model* Max. Static Min. Speed Ta p T otal Heat 1 KW St aging KW MBH W1 Only W2 Only W1 + W2 208V 240V 208V 240V 208V 240V 208V 240V 208V 240V MV12B 4HK*6500506 0.5 Heat-D 3.6 4.8 12.3 16.4 3.6 4.8 3.6 4.8 3.6 4.8 4HK ...

  • York MV - page 6

    255427-YTG-F-1006 6 Unitary Products Group ELECTRICAL DA T A (FOR SINGLE SOURCE POWER SUPPL Y) - COPPER WIRE 208/230-1-60 Model Heater Model 1,* Field W iring Heater Amps Amp acity Min. Circuit Max. O.C.P . 2 Amp s/T ype Wire Size - AW G 75°C 240V 208V 240V 208V 240V 208V 240V MV12B 4HK*6500506 20.0 27.54 30.38 30 35 10 8 4HK*6500806 31.3 39.73 44 ...

  • York MV - page 7

    255427-YTG-F-1006 Unitary Products Group 7 POWER WIRING ELECTRICAL DA T A (FOR MUL TI SOURCE PO WER SUPPL Y) - COPPER WIRE 208/230-1-60 Model Heater Model Min. Circuit Ampacity Max. O.C.P . 1 Amp s/T ype 75°C Wi re Size - A W G Circuit Circuit Circ uit 1st 2nd 3rd 1st 2nd 3rd 1st 2nd 3rd 208/240 208/240 208/240 208/240 208/ 240 208/240 208/240 208 ...

  • York MV - page 8

    255427-YTG-F-1006 8 Unitary Products Group ACCESSORIES Refer to Price Manual for specific model numbers. Electric Heaters - Mo dels shown under Electrical Data include sequencers and temperat ure limit switches and fus- ible links for safe, efficient operation. Circuit breakers are pro- vided where shown. Suspension Kit - Suspensio n Kit Model 1BH0 ...

  • York MV - page 9

    255427-YTG-F-1006 Unitary Products Group 9 COMBUSTIBLE FLOOR BASE ACCESSORY DOWNFLOW AIR HANDLER WARM AIR PLENUM WITH 1” FLANGES FIBERGLASS INSULA TION FIBERGLASS T APE UNDER FLANGE COMBUSTIBLE FLOOR BASE ACCESSORY A B B A AIR HANDLER DEPTH FRONT FLOOR 1 10-47/64 PLENUM 12-1/2 FLOOR OPENING APPROX. 1/2” CLEARANCE ALL AROUND FLOOR A AIR HANDLER ...

  • York MV - page 10

    255427-YTG-F-1006 10 Unitary Products Group COOLING AIRFLOW DA T A - MV MODELS HIGH / LOW SPEED COOLING AND HEA T PU MP CFM 12B Air Handler 12D Air Handler JUMPER SETTINGS CFM m 3 /min CFM m 3 /min High Low High Low High Low High Low COOL T ap ADJ T ap* 1307 882 37.0 25.0 1366 869 38 .7 24.6 A B 1080 756 30.6 21.4 1097 717 31 .1 20.3 B B 1270 862 3 ...

  • York MV - page 11

    255427-YTG-F-1006 Unitary Products Group 11 APPLICA TION F ACT ORS - RA TED CFM VS. ACTUAL CFM % OF RA T ED AIR FLOW 80% 90% RA TED C FM 1 10% 120% CAP ACIT Y F ACT OR 0.96 0.98 1.00 1.02 1.03 T ypical Applications with MC Mu lti-Position Coils Up Flow Down Flow Horizontal Right Horizontal Left COOLING MODELS WITH ELECTRIC HEA T MA SERIES - Air Han ...

  • York MV - page 12

    Subject to change without notice. Printe d in U .S.A. 255427-YTG-F-1006 Copyright © by York International/JCI. 2006. All rig hts reserved. Supersedes: 255427-YTG-E-0906 Unitary 5005 Norman Product s Y ork OK Group Drive 73069 NOTES ...

Fabricant York Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilYork MV peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques York
- manuels d’utilisations MV
- fiches produit York
- dépliants
- ou étiquettes-énergie York MV
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation York MV.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation York MV, manuels d’entretien, brefs manuels ou manuels de l’utilisateur York MV. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit York MV.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil York MV, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser York MV par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs York MV.

Le manuel d’utilisation complet York, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel York MV - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières York MV, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lYork MV qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil York MV - qui devraient nous aider dans les premières étapes lors de l'utilisation York MV
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de York MV
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service York MV dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de York MV?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec York MV, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec York MV il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)