    TECHNICAL GUIDE MODELS: MV MODULAR V ARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEA T PUMP 1200 - 200 0 CFM BLOWERS 3 - 5 T ON COILS OPTIONAL 1 & 3 φ ELECTRIC HEA TERS Due to conti nu ous prod uct improvem en t, specifica tion s subject to change withou t notice. Visit us on the web at www. york.com Additional rat ing i ...

  • York MV - page 2

    255427-YTG-F-1006 2 Unitary Products Group DIMENSIONS - (BLOWER WITH MC COILS) NOTE: Power wiring may be brought into the unit through one of the kn ockouts in either the top or the left side panel. Multiple knockouts are provided to accommodate all of the electric heat and transformer accessorie s that are availabl e. Use the knock- outs that prov ...

  • York MV - page 3

    255427-YTG-F-1006 Unitary Products Group 3 COOLING CAP ACITY - COIL ONL Y Blower Model Coil Model Rated CFM Entering Air ° F (Dry / Wet Bulb) MBH @ Evaporator T emperature and Corresponding Pressure °F / PSIG 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 Multi-Position - Upflow / Downflow / Horizont al MV12B MC30B**H 1025 85 / 72 41.5 37.8 33.7 29.5 80 ...

  • York MV - page 4

    255427-YTG-F-1006 4 Unitary Products Group PHYSICAL & ELECTRICAL DA T A Model MV12B MV12D MV16C MV20D Blower - Diameter x Width 10 x 7 10 x 10 10 x 10 10 x 10 Motor HP 1/2 1/2 3/4 1 Nominal RPM 1200 1200 1200 1200 V oltage 208/230 Amps Full Load (230) 4.3 4.3 5.0 7.0 Filter T ype DISPOSABLE OR PERMANENT Size 16 x 20 x 1 22 x 20 x 1 20 x 20 x 1 ...

  • York MV - page 5

    255427-YTG-F-1006 Unitary Products Group 5 * May be 0 (no breaker) or 1 (with breaker). ELECTRICAL DA T A - 208/230-1-60 Model Heater Model* Max. Static Min. Speed Ta p T otal Heat 1 KW St aging KW MBH W1 Only W2 Only W1 + W2 208V 240V 208V 240V 208V 240V 208V 240V 208V 240V MV12B 4HK*6500506 0.5 Heat-D 3.6 4.8 12.3 16.4 3.6 4.8 3.6 4.8 3.6 4.8 4HK ...

  • York MV - page 6

    255427-YTG-F-1006 6 Unitary Products Group ELECTRICAL DA T A (FOR SINGLE SOURCE POWER SUPPL Y) - COPPER WIRE 208/230-1-60 Model Heater Model 1,* Field W iring Heater Amps Amp acity Min. Circuit Max. O.C.P . 2 Amp s/T ype Wire Size - AW G 75°C 240V 208V 240V 208V 240V 208V 240V MV12B 4HK*6500506 20.0 27.54 30.38 30 35 10 8 4HK*6500806 31.3 39.73 44 ...

  • York MV - page 7

    255427-YTG-F-1006 Unitary Products Group 7 POWER WIRING ELECTRICAL DA T A (FOR MUL TI SOURCE PO WER SUPPL Y) - COPPER WIRE 208/230-1-60 Model Heater Model Min. Circuit Ampacity Max. O.C.P . 1 Amp s/T ype 75°C Wi re Size - A W G Circuit Circuit Circ uit 1st 2nd 3rd 1st 2nd 3rd 1st 2nd 3rd 208/240 208/240 208/240 208/240 208/ 240 208/240 208/240 208 ...

  • York MV - page 8

    255427-YTG-F-1006 8 Unitary Products Group ACCESSORIES Refer to Price Manual for specific model numbers. Electric Heaters - Mo dels shown under Electrical Data include sequencers and temperat ure limit switches and fus- ible links for safe, efficient operation. Circuit breakers are pro- vided where shown. Suspension Kit - Suspensio n Kit Model 1BH0 ...

  • York MV - page 9

    255427-YTG-F-1006 Unitary Products Group 9 COMBUSTIBLE FLOOR BASE ACCESSORY DOWNFLOW AIR HANDLER WARM AIR PLENUM WITH 1” FLANGES FIBERGLASS INSULA TION FIBERGLASS T APE UNDER FLANGE COMBUSTIBLE FLOOR BASE ACCESSORY A B B A AIR HANDLER DEPTH FRONT FLOOR 1 10-47/64 PLENUM 12-1/2 FLOOR OPENING APPROX. 1/2” CLEARANCE ALL AROUND FLOOR A AIR HANDLER ...

  • York MV - page 10

    255427-YTG-F-1006 10 Unitary Products Group COOLING AIRFLOW DA T A - MV MODELS HIGH / LOW SPEED COOLING AND HEA T PU MP CFM 12B Air Handler 12D Air Handler JUMPER SETTINGS CFM m 3 /min CFM m 3 /min High Low High Low High Low High Low COOL T ap ADJ T ap* 1307 882 37.0 25.0 1366 869 38 .7 24.6 A B 1080 756 30.6 21.4 1097 717 31 .1 20.3 B B 1270 862 3 ...

  • York MV - page 11

    255427-YTG-F-1006 Unitary Products Group 11 APPLICA TION F ACT ORS - RA TED CFM VS. ACTUAL CFM % OF RA T ED AIR FLOW 80% 90% RA TED C FM 1 10% 120% CAP ACIT Y F ACT OR 0.96 0.98 1.00 1.02 1.03 T ypical Applications with MC Mu lti-Position Coils Up Flow Down Flow Horizontal Right Horizontal Left COOLING MODELS WITH ELECTRIC HEA T MA SERIES - Air Han ...

  • York MV - page 12

    Subject to change without notice. Printe d in U .S.A. 255427-YTG-F-1006 Copyright © by York International/JCI. 2006. All rig hts reserved. Supersedes: 255427-YTG-E-0906 Unitary 5005 Norman Product s Y ork OK Group Drive 73069 NOTES ...

Manufacturer York Category Air Conditioner

Documents that we receive from a manufacturer of a York MV can be divided into several groups. They are, among others:
- York technical drawings
- MV manuals
- York product data sheets
- information booklets
- or energy labels York MV
All of them are important, but the most important information from the point of view of use of the device are in the user manual York MV.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals York MV, service manual, brief instructions and user manuals York MV. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product York MV.

Similar manuals

A complete manual for the device York MV, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use York MV by users. Manuals are usually written by a technical writer, but in a language understandable to all users of York MV.

A complete York manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual York MV - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the York MV, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the York MV, that we can find in the current document
3. Tips how to use the basic functions of the device York MV - which should help us in our first steps of using York MV
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with York MV
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of York MV in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning York MV?

Use the form below

If you did not solve your problem by using a manual York MV, ask a question using the form below. If a user had a similar problem with York MV it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)