Manuel d’utilisation Lennox Hearth 038M

24 pages 1.55 mb
Télécharger

Aller à la page of 24

Summary
  • Lennox Hearth 038M - page 1

    EP A Wood-Burning Fireplace P/N 850,038M REV . B 02/2007 MONTEST MODEL MONTECITO EST A TE™ This installation manual will enable you to obtain a safe, efficient and de - pendable installation of your fireplace system. Please read and understan d these instructions before beginning your installation. Do not alter or modify the fireplace or its c ...

  • Lennox Hearth 038M - page 2

    W ARNING T o avoid the risk of damaging fireplace materials and increas- ing the risk of fire, do not use the fireplace to cook or warm food. W ARNING NEVER use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fluid, naphtha, engine oil or similar liquids to start or “freshen up” a fire in this fireplace. Keep any flamma ...

  • Lennox Hearth 038M - page 3

    T ABLE OF CONTENTS Safety Rules ...................................... Page 2 Introduction ...................................... Page 3 Parts Required ................................. Page 3 Optional Equipment ........................... Page 3 Operating The Mo nte cit o E sta te ......... Page 3 Fuel ............................................. ...

  • Lennox Hearth 038M - page 4

    The combustion air control should be opened before opening the doors to minimize the possi- bility of back draft coming into the room ( Figure 1-A ) More details are available in Refueling For Best Performance on Page 5 . Time Delayed Air Boost System The time delayed air-boost system register is located underneath the door handles. Placed in the f ...

  • Lennox Hearth 038M - page 5

    The unit will burn best with 2-3 pieces of cord wood spaced 1 to 2 inches apart and allowing air to get under the fuel. Criss-crossing or ar - ranging the fuel so that air can get underneath will help the fire to get started easily . The unit should be operated with the air control fully open long enough to get the cord wood well ignited. REFUELIN ...

  • Lennox Hearth 038M - page 6

    Figure 5 IMPORT ANT CAUTIONS A. Do not block the hot air vents to the fire- place as this will cause the fireplace to overheat. B. Never use gasoline, kerosene, charcoal lighter fluid or similar liquids to start or rekindle a fire in this fireplace. Keep all such liquids well away from the fireplace at all times. C. Do not burn coal. The sulp ...

  • Lennox Hearth 038M - page 7

    DOOR INST ALLA TION The doors must be put in place only when the installation of the Montecito Estate™ is completed. All you have to do is fit the male part of the hinge, already on the door , to the female part, which is on the fireplace. T o remove the doors, simply pull them up from the hinges. The door adjustment has been set at the factor ...

  • Lennox Hearth 038M - page 8

    FIREPLACE INST ALLA TION Locating The Montecito Estate™ The best location to install your fireplace is determined by considering the location of windows, doors, and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the locatio ...

  • Lennox Hearth 038M - page 9

    Figure 11 Insulated Chase Construction 7 Ft. Min. Attic Radiation Shield Ro of Su pp or t Storm Collar Flashing Dr yw al l o r An y Ri g id Ma te ri a l 2” x 4” 1/2” Plywood 6’ 8” Min. Firestop * Floor Ceiling Wall * Floor Ceiling Wall Fireplace Insulate Joists Same As Ceiling Draft Stops Firestop CTDT T ermination Note: Non- Combustible ...

  • Lennox Hearth 038M - page 10

    1. Combusti ble material must be insta lled flush with the fireplace. It may not project in front of and on the fireplace (i.e. the steel facade of the fireplace) ( Figure 14 ) . 2. Non-combustible materials such as brick, stone or ceramic tile may project in front of and onto the fireplace facing ( Figure 13 ) . MANTEL & F ACING The mante ...

  • Lennox Hearth 038M - page 11

    Figure 17 13” x 13” 10’ Max. 10’ Max. Rain Cap Flashing Collar Flashing Roof Support Attic Radiation Shield No n- Com bu st ibl e Fl am epr oo f Fa ci ng 56” Min. 68” Min. Figure 18 The duct system must be installed respecting the following: 1. Remove the plates closing up the 8” dia. holes on top of the fireplace. Then, cut the insu ...

  • Lennox Hearth 038M - page 12

    OUTSIDE AIR KIT It is mandatory to install an outside air connection to the Montecito Estate™. The following components are required and are included with the fireplace: - Outside air kit (includes 40 inch flex that goes up to ten (10) feet long) - 4” Adaptor for fireplace connection Outside Air Installation The outside air assembly may be i ...

  • Lennox Hearth 038M - page 13

    8. A rain cap must be installed on top of the chimney . Failure to install a rain cap may cause corrosion problems. 9. Cut and frame square holes in all floors, ceilings, and roof that the chimney will go through to provide a 2” (50 mm) clearance between the chimney and any combustible materials. Do not fill this 2” space with insulation or a ...

  • Lennox Hearth 038M - page 14

    CHIMNEY INST ALLA TION INSTRUC- TIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 22 ). Use a plumb bob to line up the center of the holes. The sizes are indicated in T able 2 for the floor and ceiling holes and T able 3 ( Page 15 ) for the roof holes. Fro m belo w , ins tall a firest op in e ...

  • Lennox Hearth 038M - page 15

    Roof Down Slope Hole Size D E GR E E O F SL O P E S e cu r e T e mp ™ S 21 0 0 + N o va T e m p™ H T 6 0 0 0 + S e cu r e T e mp G X A C BI R o of P i t c h 7 ” 7 ” 0 * 1 5 ” ( 3 8 0 m m) 1 5 ” ( 3 8 0 m m) 2 / 12 1 5 -3 / 8 ” ( 3 90 m m ) 1 5 -3 / 8 ” ( 3 90 m m ) 4 / 12 1 6 -1 / 8 ” ( 4 10 m m ) 1 6 -1 / 8 ” ( 4 10 m m ) 6 / 1 ...

  • Lennox Hearth 038M - page 16

    OFFSET CHIMNEY INST ALLA TION The minimum chimney height when using elbows is: C h i m n ey Elbow Offset & Height T wo Lengths Between Elbows 8” 12” 18” 24” 36” 8” & 36” 1 2” & 36 ” 1 8” & 36 ” 2 4 ” & 3 6” 36” & 36” GX S2 10 0+ HT 60 00 + 7” 15º A 3” (7 6 m m) 4- 1/4 ” (1 08 mm ) 5- 3/4 ...

  • Lennox Hearth 038M - page 17

    Figure 28 OFFSET CHIMNEY INST ALLA TION Rain Cap Collar Roof Flashing Offset Support Insulated Wall Radiation Shield Framing 2” x 3” Figure 29 Roof Support Note: In cold areas it is recommended to protect the chimney in a insulated chase. Straps Chimney ACBI ACBI Starter Section Straps Outside Wall OFFSET CHIMNEY INST ALLA TION WITH WALL PENETR ...

  • Lennox Hearth 038M - page 18

    ANGLED WALL RADIA TION SHIELD (XRSMI30 and AC10RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Note: 45º angle for Canada only (XRSMI45). In cold climate locations (climates where temperatures will fall below 32º F / 0º C), ...

  • Lennox Hearth 038M - page 19

    INST ALLA TION INSTRUCTIONS FOR MASONRY APPLICA TION WARNING: Before starting the installation, the masonry chimney must be inspected by a qualified chimney sweep. The following requirements must be respected: 1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing bricks that could inhibit corre ...

  • Lennox Hearth 038M - page 20

    CHIMNEY - P ARTS AND COMPONENTS LISTS Secure T emp GX - 2” Insulated Galvanized Chimney System (Recommended Insulated System) Galvanized (7” ID & 11” OD) U.S.A. ONL Y Description Cat./Part No. Lengths & Misc. Chimney Components Length 8”, 7GXL8 7GXL8 Length 12”, 7GXL12 7GXL12 Length 18”, 7GXL18 7GXL18 Length 24”, 7GXL24 7GXL24 ...

  • Lennox Hearth 038M - page 21

    ACBI Chimney* (7” I.D., 13” O.D. AC - Air Cooled) * AC Ch im ne y i s NO T r ec om me n de d a t el ev at i on s a bo ve 4 ,0 0 0 fe e t or i n c ol d c li ma te s ( cl im at es wh er e te m pe ra tu re s w il l fa l l be l ow 3 2° F / 0° C ). Description Cat./Part No. One of the following adaptors is required if installing an AC chimney syst ...

  • Lennox Hearth 038M - page 22

    CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation: • Side wall (fireplace front): 24” (457 mm) measured from the fireplace side. • Ceiling: 6’ 8” (2,032 mm) measured from the base of the fireplace • Fireplace enclosure: Bottom: 0” Side: 0” Back: 0” • T op: Do not fill th ...

  • Lennox Hearth 038M - page 23

    NOTES 23 ...

  • Lennox Hearth 038M - page 24

    Printed in Canada © 2006 by LENNOX HEARTH PRODUCTS P/N 850,038M REV . B 02/2007 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. LHP 1110 West T aft Avenu ...

Fabricant Lennox Hearth Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilLennox Hearth 038M peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lennox Hearth
- manuels d’utilisations 038M
- fiches produit Lennox Hearth
- dépliants
- ou étiquettes-énergie Lennox Hearth 038M
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lennox Hearth 038M.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lennox Hearth 038M, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lennox Hearth 038M. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lennox Hearth 038M.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Lennox Hearth 038M, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lennox Hearth 038M par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lennox Hearth 038M.

Le manuel d’utilisation complet Lennox Hearth, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lennox Hearth 038M - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lennox Hearth 038M, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLennox Hearth 038M qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lennox Hearth 038M - qui devraient nous aider dans les premières étapes lors de l'utilisation Lennox Hearth 038M
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lennox Hearth 038M
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lennox Hearth 038M dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lennox Hearth 038M?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lennox Hearth 038M, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lennox Hearth 038M il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)