  • Lennox Hearth 038M - page 1

    EP A Wood-Burning Fireplace P/N 850,038M REV . B 02/2007 MONTEST MODEL MONTECITO EST A TE™ This installation manual will enable you to obtain a safe, efficient and de - pendable installation of your fireplace system. Please read and understan d these instructions before beginning your installation. Do not alter or modify the fireplace or its c ...

  • Lennox Hearth 038M - page 2

    W ARNING T o avoid the risk of damaging fireplace materials and increas- ing the risk of fire, do not use the fireplace to cook or warm food. W ARNING NEVER use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fluid, naphtha, engine oil or similar liquids to start or “freshen up” a fire in this fireplace. Keep any flamma ...

  • Lennox Hearth 038M - page 3

    T ABLE OF CONTENTS Safety Rules ...................................... Page 2 Introduction ...................................... Page 3 Parts Required ................................. Page 3 Optional Equipment ........................... Page 3 Operating The Mo nte cit o E sta te ......... Page 3 Fuel ............................................. ...

  • Lennox Hearth 038M - page 4

    The combustion air control should be opened before opening the doors to minimize the possi- bility of back draft coming into the room ( Figure 1-A ) More details are available in Refueling For Best Performance on Page 5 . Time Delayed Air Boost System The time delayed air-boost system register is located underneath the door handles. Placed in the f ...

  • Lennox Hearth 038M - page 5

    The unit will burn best with 2-3 pieces of cord wood spaced 1 to 2 inches apart and allowing air to get under the fuel. Criss-crossing or ar - ranging the fuel so that air can get underneath will help the fire to get started easily . The unit should be operated with the air control fully open long enough to get the cord wood well ignited. REFUELIN ...

  • Lennox Hearth 038M - page 6

    Figure 5 IMPORT ANT CAUTIONS A. Do not block the hot air vents to the fire- place as this will cause the fireplace to overheat. B. Never use gasoline, kerosene, charcoal lighter fluid or similar liquids to start or rekindle a fire in this fireplace. Keep all such liquids well away from the fireplace at all times. C. Do not burn coal. The sulp ...

  • Lennox Hearth 038M - page 7

    DOOR INST ALLA TION The doors must be put in place only when the installation of the Montecito Estate™ is completed. All you have to do is fit the male part of the hinge, already on the door , to the female part, which is on the fireplace. T o remove the doors, simply pull them up from the hinges. The door adjustment has been set at the factor ...

  • Lennox Hearth 038M - page 8

    FIREPLACE INST ALLA TION Locating The Montecito Estate™ The best location to install your fireplace is determined by considering the location of windows, doors, and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the locatio ...

  • Lennox Hearth 038M - page 9

    Figure 11 Insulated Chase Construction 7 Ft. Min. Attic Radiation Shield Ro of Su pp or t Storm Collar Flashing Dr yw al l o r An y Ri g id Ma te ri a l 2” x 4” 1/2” Plywood 6’ 8” Min. Firestop * Floor Ceiling Wall * Floor Ceiling Wall Fireplace Insulate Joists Same As Ceiling Draft Stops Firestop CTDT T ermination Note: Non- Combustible ...

  • Lennox Hearth 038M - page 10

    1. Combusti ble material must be insta lled flush with the fireplace. It may not project in front of and on the fireplace (i.e. the steel facade of the fireplace) ( Figure 14 ) . 2. Non-combustible materials such as brick, stone or ceramic tile may project in front of and onto the fireplace facing ( Figure 13 ) . MANTEL & F ACING The mante ...

  • Lennox Hearth 038M - page 11

    Figure 17 13” x 13” 10’ Max. 10’ Max. Rain Cap Flashing Collar Flashing Roof Support Attic Radiation Shield No n- Com bu st ibl e Fl am epr oo f Fa ci ng 56” Min. 68” Min. Figure 18 The duct system must be installed respecting the following: 1. Remove the plates closing up the 8” dia. holes on top of the fireplace. Then, cut the insu ...

  • Lennox Hearth 038M - page 12

    OUTSIDE AIR KIT It is mandatory to install an outside air connection to the Montecito Estate™. The following components are required and are included with the fireplace: - Outside air kit (includes 40 inch flex that goes up to ten (10) feet long) - 4” Adaptor for fireplace connection Outside Air Installation The outside air assembly may be i ...

  • Lennox Hearth 038M - page 13

    8. A rain cap must be installed on top of the chimney . Failure to install a rain cap may cause corrosion problems. 9. Cut and frame square holes in all floors, ceilings, and roof that the chimney will go through to provide a 2” (50 mm) clearance between the chimney and any combustible materials. Do not fill this 2” space with insulation or a ...

  • Lennox Hearth 038M - page 14

    CHIMNEY INST ALLA TION INSTRUC- TIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 22 ). Use a plumb bob to line up the center of the holes. The sizes are indicated in T able 2 for the floor and ceiling holes and T able 3 ( Page 15 ) for the roof holes. Fro m belo w , ins tall a firest op in e ...

  • Lennox Hearth 038M - page 15

    Roof Down Slope Hole Size D E GR E E O F SL O P E S e cu r e T e mp ™ S 21 0 0 + N o va T e m p™ H T 6 0 0 0 + S e cu r e T e mp G X A C BI R o of P i t c h 7 ” 7 ” 0 * 1 5 ” ( 3 8 0 m m) 1 5 ” ( 3 8 0 m m) 2 / 12 1 5 -3 / 8 ” ( 3 90 m m ) 1 5 -3 / 8 ” ( 3 90 m m ) 4 / 12 1 6 -1 / 8 ” ( 4 10 m m ) 1 6 -1 / 8 ” ( 4 10 m m ) 6 / 1 ...

  • Lennox Hearth 038M - page 16

    OFFSET CHIMNEY INST ALLA TION The minimum chimney height when using elbows is: C h i m n ey Elbow Offset & Height T wo Lengths Between Elbows 8” 12” 18” 24” 36” 8” & 36” 1 2” & 36 ” 1 8” & 36 ” 2 4 ” & 3 6” 36” & 36” GX S2 10 0+ HT 60 00 + 7” 15º A 3” (7 6 m m) 4- 1/4 ” (1 08 mm ) 5- 3/4 ...

  • Lennox Hearth 038M - page 17

    Figure 28 OFFSET CHIMNEY INST ALLA TION Rain Cap Collar Roof Flashing Offset Support Insulated Wall Radiation Shield Framing 2” x 3” Figure 29 Roof Support Note: In cold areas it is recommended to protect the chimney in a insulated chase. Straps Chimney ACBI ACBI Starter Section Straps Outside Wall OFFSET CHIMNEY INST ALLA TION WITH WALL PENETR ...

  • Lennox Hearth 038M - page 18

    ANGLED WALL RADIA TION SHIELD (XRSMI30 and AC10RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Note: 45º angle for Canada only (XRSMI45). In cold climate locations (climates where temperatures will fall below 32º F / 0º C), ...

  • Lennox Hearth 038M - page 19

    INST ALLA TION INSTRUCTIONS FOR MASONRY APPLICA TION WARNING: Before starting the installation, the masonry chimney must be inspected by a qualified chimney sweep. The following requirements must be respected: 1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing bricks that could inhibit corre ...

  • Lennox Hearth 038M - page 20

    CHIMNEY - P ARTS AND COMPONENTS LISTS Secure T emp GX - 2” Insulated Galvanized Chimney System (Recommended Insulated System) Galvanized (7” ID & 11” OD) U.S.A. ONL Y Description Cat./Part No. Lengths & Misc. Chimney Components Length 8”, 7GXL8 7GXL8 Length 12”, 7GXL12 7GXL12 Length 18”, 7GXL18 7GXL18 Length 24”, 7GXL24 7GXL24 ...

  • Lennox Hearth 038M - page 21

    ACBI Chimney* (7” I.D., 13” O.D. AC - Air Cooled) * AC Ch im ne y i s NO T r ec om me n de d a t el ev at i on s a bo ve 4 ,0 0 0 fe e t or i n c ol d c li ma te s ( cl im at es wh er e te m pe ra tu re s w il l fa l l be l ow 3 2° F / 0° C ). Description Cat./Part No. One of the following adaptors is required if installing an AC chimney syst ...

  • Lennox Hearth 038M - page 22

    CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation: • Side wall (fireplace front): 24” (457 mm) measured from the fireplace side. • Ceiling: 6’ 8” (2,032 mm) measured from the base of the fireplace • Fireplace enclosure: Bottom: 0” Side: 0” Back: 0” • T op: Do not fill th ...

  • Lennox Hearth 038M - page 23

    NOTES 23 ...

  • Lennox Hearth 038M - page 24

    Printed in Canada © 2006 by LENNOX HEARTH PRODUCTS P/N 850,038M REV . B 02/2007 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. LHP 1110 West T aft Avenu ...

Производитель Lennox Hearth Категория Indoor Fireplace

Документы, которые мы получаем от производителя устройства Lennox Hearth 038M мы можем разделить на несколько групп. Это в частности:
- технические чертежи Lennox Hearth
- инструкции обслуживания 038M
- паспорта изделия Lennox Hearth
- информационные брошюры
- энергетические этикетки Lennox Hearth 038M
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Lennox Hearth 038M.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Lennox Hearth 038M, инструкции обслуживания, короткие инструкции или инструкции пользователя Lennox Hearth 038M. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Lennox Hearth 038M.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Lennox Hearth 038M, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Lennox Hearth 038M пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Lennox Hearth 038M.

Полная инструкция обслуживания Lennox Hearth, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Lennox Hearth 038M - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Lennox Hearth 038M, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Lennox Hearth 038M, которое найдем в данном документе
3. Советы по использованию основных функций устройства Lennox Hearth 038M - которые должны облегчить нам первые шаги во время использования Lennox Hearth 038M
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Lennox Hearth 038M
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Lennox Hearth 038M в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Lennox Hearth 038M?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Lennox Hearth 038M, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Lennox Hearth 038M со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)