    HEA VY -DUTY AIR CHIPPING HAMMER 99792 SET UP AND OPERA TING INSTRUCTIONS Distributed exclusively by Harbor Freight T ools ® . 3491 Mission Oaks Blvd., Camarillo, CA 9301 1 Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright ? ...

  • Central Pneumatic 99792 - page 2

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 2 CONTENTS SAFETY ALERT SYMBOL AND SIGNAL WORDS ............................. 3 IMPORT ANT SAFETY INSTRUCTIONS .......................... 3 GENERAL ........................................... 3 WORK AREA ...................................... 3 PERSONAL SAFETY ..................... ...

  • Central Pneumatic 99792 - page 3

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 3 SA VE THIS MANUAL Keep this manual for the safety warn- ings and precautions, assembly , operat- ing, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year of purchase if produc ...

  • Central Pneumatic 99792 - page 4

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 4 tool. Distractions are able to result in the loss of control of the tool. Personal safety a. Stay alert. Watch what you are do- ing and use common sense when operating the tool. Do not use the tool while tired or under the inu - ence of drugs, alcohol, or medica- tion. A momen ...

  • Central Pneumatic 99792 - page 5

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 5 d. Disconnect the tool from the air source before making any adjust- ments, changing accessories, or storing the tool. Such preventive safety measures reduce the risk of starting the tool unintentionally . T urn off and detach the air supply , safely discharge any residual air pr ...

  • Central Pneumatic 99792 - page 6

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 6 Symbol Denitions Symbol Property or statement ft-lb Foot-pounds of torque BPM Blows per minute CFM Cubic Feet per Minute ow SCFM Cubic Feet per Minute ow at standard conditions NPT National pipe thread, tapered NPS National pipe thread, straight W ARNING marking concerni ...

  • Central Pneumatic 99792 - page 7

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 7 a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to lter out microscopic particles. (California Health & Safety Code § 25249.5, et seq. ) W ARNING: The brass components of this product contain lead, a ch ...

  • Central Pneumatic 99792 - page 8

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 8 FUNCTIONAL DESCRIPTION Specications Chipping Rate 1800 Blows per Minute Chisel Shank Diameter 1 1/16" Operating Pressure 90 PSI Air Inlet 3/8" - 18 NPT Air Consumption 20 CFM (Continuous) 10 CFM (Intermittent) Overall Length 17" Net Weight 17.5Lbs * Maximum spee ...

  • Central Pneumatic 99792 - page 9

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 9 quick coupler , will make operation more efcient, but are not required. W ARNING! TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: Do not install a female quick coupler on the tool. Such a coupler contains an air valve that will allow the air tool to retain pressure and ...

  • Central Pneumatic 99792 - page 10

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 10 pull out the Lockcoil Spring (17) from the Retaining Sleeve (16). This spring is designed as a locking device. Then remove the Retaining Sleeve (16) from the hammer . 3. Fig. 2 Put the spring aside. Lubricate the top edge of the chisel shank chamfer with oil or light grease and ...

  • Central Pneumatic 99792 - page 11

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 1 1 8. Fig. 5 Re-insert the Lockcoil Spring (17) all the way into the slot on the sleeve with only the triangular wire ring left outside (see Fig. 5). Pull on the chisel vigorously to make sure the chisel is securely locked into the Retain- ing Sleeve (16) before attaching the Chip ...

  • Central Pneumatic 99792 - page 12

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 12 Chipping in a Straight line: 1. Use chalk or some other suitable writing material, mark your work surface to delineate the area you intend to chip. 2. Once the Hammer is attached to the Air Compressor as described in the instructions, place the Chisel along one of the marked lin ...

  • Central Pneumatic 99792 - page 13

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 13 USER-MAINTENANCE INSTRUCTIONS Procedures not specically explained in this manual must be performed only by a qualied technician. TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: T urn off the tool, detach the air supply , safely discharge any residual air pressure i ...

  • Central Pneumatic 99792 - page 14

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 14 T roubleshooting Problem Possible Causes Likely Solutions Decreased output. 1. Not enough air pressure and/ or air ow . 2. Obstructed trigger . 3. Incorrect lubrication or not enough lubrication. 4. Blocked air inlet screen (if equipped). 5. Air leaking from loose housing. 6. ...

  • Central Pneumatic 99792 - page 15

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 15 PLEASE READ THE FOLLOWING CAREFULL Y THE MANUF ACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE P ARTS LIST AND ASSEMBL Y DIAGRAM IN THIS MANUAL AS A REFERENCE T OOL ONL Y . NEITHER THE MANUF ACTURER OR DISTRIBUTOR MAKES ANY REPRESENT A TION OR WARRANTY OF ANY KIND TO THE BUYER THA T ...

  • Central Pneumatic 99792 - page 16

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 16 ASSEMBL Y DIAGRAM ...

  • Central Pneumatic 99792 - page 17

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 17 Record Product’ s Serial Number Here: Note: If product has no serial number , record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only , and are not avail- able individually as replacement parts. 90 Day W arranty Harbor Fr ...

Fabricant Central Pneumatic Catégorie Impact Driver

Les documents que nous recevons du fabricant de l'appareilCentral Pneumatic 99792 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Central Pneumatic
- manuels d’utilisations 99792
- fiches produit Central Pneumatic
- dépliants
- ou étiquettes-énergie Central Pneumatic 99792
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Central Pneumatic 99792.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Central Pneumatic 99792, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Central Pneumatic 99792. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Central Pneumatic 99792.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Central Pneumatic 99792, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Central Pneumatic 99792 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Central Pneumatic 99792.

Le manuel d’utilisation complet Central Pneumatic, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Central Pneumatic 99792 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Central Pneumatic 99792, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCentral Pneumatic 99792 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Central Pneumatic 99792 - qui devraient nous aider dans les premières étapes lors de l'utilisation Central Pneumatic 99792
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Central Pneumatic 99792
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Central Pneumatic 99792 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Central Pneumatic 99792?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Central Pneumatic 99792, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Central Pneumatic 99792 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)