    HEA VY -DUTY AIR CHIPPING HAMMER 99792 SET UP AND OPERA TING INSTRUCTIONS Distributed exclusively by Harbor Freight T ools ® . 3491 Mission Oaks Blvd., Camarillo, CA 9301 1 Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright ? ...

  • Central Pneumatic 99792 - page 2

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 2 CONTENTS SAFETY ALERT SYMBOL AND SIGNAL WORDS ............................. 3 IMPORT ANT SAFETY INSTRUCTIONS .......................... 3 GENERAL ........................................... 3 WORK AREA ...................................... 3 PERSONAL SAFETY ..................... ...

  • Central Pneumatic 99792 - page 3

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 3 SA VE THIS MANUAL Keep this manual for the safety warn- ings and precautions, assembly , operat- ing, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year of purchase if produc ...

  • Central Pneumatic 99792 - page 4

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 4 tool. Distractions are able to result in the loss of control of the tool. Personal safety a. Stay alert. Watch what you are do- ing and use common sense when operating the tool. Do not use the tool while tired or under the inu - ence of drugs, alcohol, or medica- tion. A momen ...

  • Central Pneumatic 99792 - page 5

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 5 d. Disconnect the tool from the air source before making any adjust- ments, changing accessories, or storing the tool. Such preventive safety measures reduce the risk of starting the tool unintentionally . T urn off and detach the air supply , safely discharge any residual air pr ...

  • Central Pneumatic 99792 - page 6

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 6 Symbol Denitions Symbol Property or statement ft-lb Foot-pounds of torque BPM Blows per minute CFM Cubic Feet per Minute ow SCFM Cubic Feet per Minute ow at standard conditions NPT National pipe thread, tapered NPS National pipe thread, straight W ARNING marking concerni ...

  • Central Pneumatic 99792 - page 7

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 7 a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to lter out microscopic particles. (California Health & Safety Code § 25249.5, et seq. ) W ARNING: The brass components of this product contain lead, a ch ...

  • Central Pneumatic 99792 - page 8

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 8 FUNCTIONAL DESCRIPTION Specications Chipping Rate 1800 Blows per Minute Chisel Shank Diameter 1 1/16" Operating Pressure 90 PSI Air Inlet 3/8" - 18 NPT Air Consumption 20 CFM (Continuous) 10 CFM (Intermittent) Overall Length 17" Net Weight 17.5Lbs * Maximum spee ...

  • Central Pneumatic 99792 - page 9

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 9 quick coupler , will make operation more efcient, but are not required. W ARNING! TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: Do not install a female quick coupler on the tool. Such a coupler contains an air valve that will allow the air tool to retain pressure and ...

  • Central Pneumatic 99792 - page 10

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 10 pull out the Lockcoil Spring (17) from the Retaining Sleeve (16). This spring is designed as a locking device. Then remove the Retaining Sleeve (16) from the hammer . 3. Fig. 2 Put the spring aside. Lubricate the top edge of the chisel shank chamfer with oil or light grease and ...

  • Central Pneumatic 99792 - page 11

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 1 1 8. Fig. 5 Re-insert the Lockcoil Spring (17) all the way into the slot on the sleeve with only the triangular wire ring left outside (see Fig. 5). Pull on the chisel vigorously to make sure the chisel is securely locked into the Retain- ing Sleeve (16) before attaching the Chip ...

  • Central Pneumatic 99792 - page 12

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 12 Chipping in a Straight line: 1. Use chalk or some other suitable writing material, mark your work surface to delineate the area you intend to chip. 2. Once the Hammer is attached to the Air Compressor as described in the instructions, place the Chisel along one of the marked lin ...

  • Central Pneumatic 99792 - page 13

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 13 USER-MAINTENANCE INSTRUCTIONS Procedures not specically explained in this manual must be performed only by a qualied technician. TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: T urn off the tool, detach the air supply , safely discharge any residual air pressure i ...

  • Central Pneumatic 99792 - page 14

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 14 T roubleshooting Problem Possible Causes Likely Solutions Decreased output. 1. Not enough air pressure and/ or air ow . 2. Obstructed trigger . 3. Incorrect lubrication or not enough lubrication. 4. Blocked air inlet screen (if equipped). 5. Air leaking from loose housing. 6. ...

  • Central Pneumatic 99792 - page 15

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 15 PLEASE READ THE FOLLOWING CAREFULL Y THE MANUF ACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE P ARTS LIST AND ASSEMBL Y DIAGRAM IN THIS MANUAL AS A REFERENCE T OOL ONL Y . NEITHER THE MANUF ACTURER OR DISTRIBUTOR MAKES ANY REPRESENT A TION OR WARRANTY OF ANY KIND TO THE BUYER THA T ...

  • Central Pneumatic 99792 - page 16

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 16 ASSEMBL Y DIAGRAM ...

  • Central Pneumatic 99792 - page 17

    SKU 99792 For technical questions, please call 1-800-444-3353. Page 17 Record Product’ s Serial Number Here: Note: If product has no serial number , record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only , and are not avail- able individually as replacement parts. 90 Day W arranty Harbor Fr ...

Manufacturer Central Pneumatic Category Impact Driver

Documents that we receive from a manufacturer of a Central Pneumatic 99792 can be divided into several groups. They are, among others:
- Central Pneumatic technical drawings
- 99792 manuals
- Central Pneumatic product data sheets
- information booklets
- or energy labels Central Pneumatic 99792
All of them are important, but the most important information from the point of view of use of the device are in the user manual Central Pneumatic 99792.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Central Pneumatic 99792, service manual, brief instructions and user manuals Central Pneumatic 99792. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Central Pneumatic 99792.

A complete manual for the device Central Pneumatic 99792, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Central Pneumatic 99792 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Central Pneumatic 99792.

A complete Central Pneumatic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Central Pneumatic 99792 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Central Pneumatic 99792, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Central Pneumatic 99792, that we can find in the current document
3. Tips how to use the basic functions of the device Central Pneumatic 99792 - which should help us in our first steps of using Central Pneumatic 99792
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Central Pneumatic 99792
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Central Pneumatic 99792 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Central Pneumatic 99792?

Use the form below

If you did not solve your problem by using a manual Central Pneumatic 99792, ask a question using the form below. If a user had a similar problem with Central Pneumatic 99792 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)