    INFRARED VENT -FREE PROP ANE/LP GAS SP ACE H E AT E R ML060HP A ML100HP A ML100TP A TOLL-FREE NUMBER: 1-877-886-5989 W ARNING: Improper installation, adjustment, alteration, service or mainte- nance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional info rmatio ...

  • Procom ML100HPA - page 2

    2 IMPORT ANT SAFETY INFORMA TION Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible f or use with other gases. 2. Do not place propane/LP supply tank(s) inside any ...

  • Procom ML100HPA - page 3

    3 PRODUCT IDENTIFICA TION SAFETY DEVICE A standard requirement for all vent-free room heaters. T his heater has a pilot with an Oxygen Depletion Sensor(ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater is equipped with a piezo ignitor. This system requires no matches, ...

  • Procom ML100HPA - page 4

    4 FRESH AIR FOR COMBUSTION AND VENTILA TION PROVIDING ADEQUA TE VENTILA TION The following are excerpts from National Fuel Gas Code. NFP A 54/ANS Z223.1, Section 5.3. Air for Combustion and V entilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually T ight Construction 2. Unconfined Space 3. Conf ...

  • Procom ML100HPA - page 5

    5 W ARNING: Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces. AIR FOR COMBUSTION AND VENTILA TION Continued VENTILA TION AIR V entilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating ...

  • Procom ML100HPA - page 6

    6 VENTILA TION AIR V entilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts: Y ou must provide two permanent openings: one within 12 " of the ceiling and one within 12 " of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces ...

  • Procom ML100HPA - page 7

    7 INST ALLA TION Figure 4 -Mounting clearances As V iewed From Front of Heater W ARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from floor, ceiling, and joining wall. Figure 7 - Mounting Bracket Clearances Figure 6 - Removing Lower Front Panel Of Heater F ASTENING HEA TER TO W ALL Mounting Bracket ...

  • Procom ML100HPA - page 8

    8 INST ALLA TION Figure 10 - Mounting Heater Onto Mounting Bracket Figure 8 - Folding Anchor Figure 9 - Popping Open Anchor Wing For Thin Walls Attaching Mounting Bracket T o W all Note: W all anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater. Attaching to W all Stud Method For attaching mou ...

  • Procom ML100HPA - page 9

    9 INST ALLA TION CONNECTING TO GAS SUPPL Y W ARNING: A qualified service person must connect heater to gas supply. Follow all local codes. W ARNING: This appliance requires a 3/8 " NPT (National Pipe Thread) inlet connection to the pressure regulator. CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an exte ...

  • Procom ML100HPA - page 10

    10 Figure 14 -Equipment Shutoff Valve INST ALLA TION CHECKING GAS CONNECTIONS W ARNING: T est all gas piping and connections for leaks after installing or servicing. Cor- rect all leaks at once. W ARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all lea ...

  • Procom ML100HPA - page 11

    11 Figure 17 - Control Knob In The OFF Position Figure 18 - Pilot OPERA TING YOUR HEA TER Manual Control Models: ML060HP A,ML100HP A  LIGHTING  INSTRUCTIONS 1. STOP! Read the safety information on the side of heater. 2. Check that gas supply to heater is on. 3. Push in gas control knob slightly and turn clockwise to the OFF position. ( see Fi ...

  • Procom ML100HPA - page 12

    12 OPERA TING YOUR HEA TER THERMOST A T MODEL ML100TP A  FOR YOUR SAFETY  READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier t ...

  • Procom ML100HPA - page 13

    13 INSPECTING BURNER Figure 24 - Correct Pilot Flame Pattern Figure 25 - Incorrect Pilot Flame Pattern Figure 27 - Incorrect Burner Flame Pattern Figure 26 - Correct Burner Flame Pattern ODS/PILOT AND BURNER  Use a vacuum cleaner, pres - surized air, or a small, sof t bristled brush to clean. CLEANING BURNER PILOT AIR INLET HOLE We recommend tha ...

  • Procom ML100HPA - page 14

    14 TROUBLESHOOTING Note : All troubleshooting items are listed in order of operation. W ARNING: Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit. OBSERVED PROBLEM When ignitor button is pressed and control knob is pressed in and ...

  • Procom ML100HPA - page 15

    15 TROUBLESHOOTING Continued OBSERVED PROBLEM Burner(s)does not light after ODS/pilot is lit. Delayed ignition of burner(s). Burner backfiring during combustion. Burner plaque(s) does not glow. Slight smoke or odor during initial operation. Heater produces a clicking/ticking noise just after burner is lit or shut off. White powder residue forming w ...

  • Procom ML100HPA - page 16

    16 TROUBLESHOOTING Continued W ARNING: If you smell gas  Shut off gas supply .  Do not try to light any appliance.  Do not touch any electrical switch; do not use any phone in your building.  Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.  If you cannot reach your gas supplier, ...

  • Procom ML100HPA - page 17

    17 SPECIFICA TIONS Btu(available) Gas T ype Ignition Pressure Regulator setting Inlet Gas Pressure* (inches of water) Maximum Minimum Dimensions, Inches (HxWxD) Heater Carton Weight (pounds) Heater Shipping ML060HP A 6,000 propane/LP Only Piezo 10 " W.C. 14 " 11 " 19-1/8 × 14-1/8 × 6-3/8 22 × 16-3/4 × 8-1/8 12 15 Note: Dimensions ...

  • Procom ML100HPA - page 18

    18 ILLUSTRA TED P ARTS BREAKDOWN ML060HP A ...

  • Procom ML100HPA - page 19

    19 P ARTS LIST ML060HP A This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this manual. KEY NO. 1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 PA R T NUMBER MB10008 MB09003 ML006-02 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML026 ...

  • Procom ML100HPA - page 20

    20 ILLUSTRA TED P ARTS BREAKDOWN ML100HP A ...

  • Procom ML100HPA - page 21

    21 P ARTS LIST ML100HP A This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this manual. KEY NO. 1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PA R T NUMBER MB10008 MB09003 ML006-01 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML ...

  • Procom ML100HPA - page 22

    22 ILLUSTRA TED P ARTS BREAKDOWN ML100TP A ...

  • Procom ML100HPA - page 23

    23 P ART LIST ML100TP A KEY NO. 1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PA R T NUMBER MB10007 MB09003 ML006-01 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML026-02 ML069-02 845-4.8x60Z SIT544-000 ML1 1 1-02 ML056-03 MB40037 MB40039 MB40038 MB40040 ML090-04 MB40041 NRV81FI-10 ML129-02 ML079-01 MB29003 ML060-02 ML083-03 MB2800 ...

Fabricant Procom Catégorie Electric Heater

Les documents que nous recevons du fabricant de l'appareilProcom ML100HPA peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Procom
- manuels d’utilisations ML100HPA
- fiches produit Procom
- dépliants
- ou étiquettes-énergie Procom ML100HPA
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Procom ML100HPA.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Procom ML100HPA, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Procom ML100HPA. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Procom ML100HPA.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Procom ML100HPA, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Procom ML100HPA par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Procom ML100HPA.

Le manuel d’utilisation complet Procom, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Procom ML100HPA - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Procom ML100HPA, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lProcom ML100HPA qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Procom ML100HPA - qui devraient nous aider dans les premières étapes lors de l'utilisation Procom ML100HPA
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Procom ML100HPA
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Procom ML100HPA dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Procom ML100HPA?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Procom ML100HPA, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Procom ML100HPA il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)