Manuel d’utilisation Bryant 280ANV

18 pages 2.1 mb
Télécharger

Aller à la page of 18

Summary
  • Bryant 280ANV - page 1

    280ANV EVOLUTI ON R EXTREME V ARIABLE SP EED HEA T PUMP WITH PURON r REFR IGERANT (2 - - 5 T on) Installation Instructions NOTE : Read the en tire in structio n manu al b efo re starting the in stallatio n. T ABLE OF CONTENTS PA G E N O . SAFETY CONSIDERA TI ONS 2 ................................................................... INST ALLA TION RE ...

  • Bryant 280ANV - page 2

    2 Inf or ma ti on in t he se ins t al l at ion ins t ruc t ions per ta i ns only t o 280ANV se r ie s uni ts . SAF ETY CONSIDERA TI ONS Imp ro per installatio n , adju stmen t, alteration , service, m ain tenan ce, or use ca n ca us e explos i on, fi re , el ec t ri c al s hoc k, or other condi t ions w hic h ma y ca us e de a t h, per s onal inj u ...

  • Bryant 280ANV - page 3

    3 In stal la tion Reco mmend ati on s In som e cases n o ise in the living area has been traced to g as puls a ti ons f rom im prope r i nst a ll a ti on of equi pment . 1. Loca te unit awa y from windows , pati os , dec ks , etc . whe re unit oper at i on sound m ay di s tur b c ust ome r . 2. In n o ise sen sitive ap p lication s (su ch as b ed r ...

  • Bryant 280ANV - page 4

    4 Step 2 — In stal l o n a S oli d , L evel Mou n tin g Pa d If c ondi ti ons or loc a l code s r equi r e the uni t be at ta c hed to pad, ti e down bolt s shoul d be us e d a nd fa s te ne d thr ough knoc kouts provi de d in uni t ba s e pan. Ref e r t o uni t mount ing pa t te r n i n Fi g. 3 to det e rmi ne ba s e pan si z e and knockout hol ...

  • Bryant 280ANV - page 5

    5 Ste p 7 — Make P iping Conne ct ions ! W ARNING PERSONAL INJUR Y AND UNIT DAM AGE HAZARD Fai l ure t o fol l ow thi s wa rni ng could r e s ult i n per s onal i njur y or death . Rel i eve pr e ss ur e and re c over a ll re fr i ger a nt bef ore sys te m re pa ir or f i nal uni t di spos a l. U se a l l se r vic e por ts and open al l fl ow- - ...

  • Bryant 280ANV - page 6

    6 Outdoor Unit Connected to Fac tory - - App roved Ind oor Unit Outdoor uni t c onta i ns c orr e ct s ys te m re f ri ge ra nt c har ge f or oper a ti on wit h fa c tor y- - approve d, AHRI- - ra te d s ma ll e st i ndoor uni t whe n conne c te d by 15 f t. (4.57 m) of fi e ld- - suppli e d or factory - - accesso ry tu bin g , and facto ry - - s u ...

  • Bryant 280ANV - page 7

    7 500 MINUTES 0 1 23 4 5 67 1000 1500 LEAK IN SYSTEM V ACUUM TIGHT TOO W E T TIGHT DR Y SYSTEM 2000 MICRONS 2500 3000 3500 4000 4500 5000 A95424 A95424 Fig . 7 - - Deep V acu um Gra p h Fi nal T ubi ng Ch eck IMPOR T ANT : Chec k t o be c e r ta in f a ct or y tubi ng on both indoor and outdoor uni t has not shif t ed duri ng s hi pme nt. Ens ure t ...

  • Bryant 280ANV - page 8

    8 Step 10 — In sta ll Acces so ries Th ere are n o refrig eratio n circu it or electrical accesso ries req uired or availab le for installatio n with in the un it. E x ternal to th e u nit, th e same accesso ries su ch as the liq u id line so len o id, s upport f e et , snow r ac k, wi nd baf f le et c ., a r e avai l abl e on o the r Br yant uni ...

  • Bryant 280ANV - page 9

    9 Crankcase Heater Operat ion Th is u nit h as an in ternal cran k case heater that will b e energized du rin g the off cycle and is in tellig ently d eman d ed b y th e sy stem to pre ve nt the c ompr e ss or f rom bei ng the col de st par t of the s yst e m thu s en han cin g t he reliab ility. Th e cran kcase h eater w ill fu nctio n as ne e de ...

  • Bryant 280ANV - page 10

    10 Th e co n tro l b o ard accum u lates com presso r run tim e. A s th e accum u lated run tim e appro ach es the selected defrost in terval time, the c ont rol boa r d monit ors t he c oil t em per a tur e s ens or f or a def ros t dem and . If a d efro st d eman d ex ists, a d efro st cy cle w ill be in itiated at the en d of th e selected time ...

  • Bryant 280ANV - page 11

    11 0 50 100 150 200 250 300 350 400 0 1 02 03 04 05 06 0 V apor Service V alve Pressure Suction Pressure For use in Heating Charging Mode only Heating Check Chart - 280ANV024/036 See user interface set in Charging Mode Charging In Cooling Mode - 280ANV024/036 (-18ºC) (-12ºC) (-10ºC) (-7ºC) (4ºC) (10ºC) (16ºC) Outdoor Ambient T emperature ºF ...

  • Bryant 280ANV - page 12

    12 MAJOR COMPONENTS V ariab le speed C on tr ol Board The HP cont rol boa rd cont r ols t he fol l owing func t ions : S Co mp resso r sp eed S Conta c tor ope r at i on S Outdoor f a n motor ope ra t ion S Reve r si ng valve ope r at i on S Defro st op eratio n S Lo w am bien t co o ling S Cran k case heater o peratio n S Pressu re sw itch m on it ...

  • Bryant 280ANV - page 13

    13 Pres s ur e Swit ch Pro tection The outdoor unit is e quippe d wi th high pr es s ure s wi tc h. If t he cont r ol se ns es the openi ng of a high pres s ure s wi tc h, it wil l re s pond as fol l ows : 1. D e - - en ergize th e co ntacto r . 2. Kee p the outdoor fa n oper a ti ng f or 15 mi nut es . 3. Dis pla y the a ppropr i at e f aul t code ...

  • Bryant 280ANV - page 14

    14 Outd oo r Coil T hermis tor The outdoor c oi l ther mi st or i s a 10Kohm r es i st or us ed for mu ltiple system o peratio n s. It pro v id es the co il/liq uid lin e temp erature to the h eat p um p b o ard an d user in terface. Lo w amb ient o p eration , defro st in itiatio n, d efro st terminatio n and assistan ce w ith OA T te mpe r at ur ...

  • Bryant 280ANV - page 15

    15 Stat us Codes T abl e 7 shows t he st a tus c ode s fl a she d by the ambe r s ta t us l i ght. Mos t s ys te m pr obl ems ca n be diagnos e d by re a di ng t he sta t us code as fl as he d by t he a mbe r sta t us l ight on the cont rol boar d. The code s a re f l as he d by a se r ie s of s hort a nd long fl a she s of the status lig h t. T h ...

  • Bryant 280ANV - page 16

    16 CB MODEL PL8 FORCED DEFROST J2 1 BRN RED SEC1 SEC2 PWM2 PWM1 INVERTER PL1 PL2 RVS CC PL1 1 PL4 PL6 OCT OA T SPT OST A B C NO USE UTIL LS Y C O COMM ST A TUS YEL BLU EXV PL5 PL3 HPS Utility Inter face* A11544 Fig. 20 - - V ariabl e Spe ed Contr ol Board with op tion a l Utility Rela y CB MODEL PL8 FORCED DEFROST J2 1 BRN RED SEC1 SEC2 PWM2 PWM1 I ...

  • Bryant 280ANV - page 17

    17 T a ble 7 – T roubl esho oti ng F AUL T DESCRI PTIO N SEN T TO UI FLASH COD E (AMBE R LED ) RESET TI ME (minut es) --- --- St andby ON, no f la sh --- --- Va r ia b le C a p ac i ty or E m e r g e n c y Mode 1, p ause --- --- V ariabl e Spee d Range Cutback 1( 2s e cO N ) ,l o n g e rp a u s e ( 1 second O FF) Communi cat ions L oss 16 NA Inva ...

  • Bryant 280ANV - page 18

    18 FINAL CHECKS IMPOR T ANT : IMPOR T ANT : Bef or e le a ving job, be sure to do th e follo win g : 1. E n sure th at all wirin g is ro u ted aw ay from tu b in g and s hee t me ta l e dge s to pre vent r ub- - through or wir e pi nchi ng. 2. Ensur e t ha t a l l wi r ing a nd tubi ng i s s e cur e in unit bef or e a ddi ng pane l s a nd c ove rs ...

Fabricant Bryant Catégorie Heat Pump

Les documents que nous recevons du fabricant de l'appareilBryant 280ANV peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Bryant
- manuels d’utilisations 280ANV
- fiches produit Bryant
- dépliants
- ou étiquettes-énergie Bryant 280ANV
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Bryant 280ANV.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Bryant 280ANV, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Bryant 280ANV. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Bryant 280ANV.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Bryant 280ANV, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Bryant 280ANV par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Bryant 280ANV.

Le manuel d’utilisation complet Bryant, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Bryant 280ANV - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Bryant 280ANV, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBryant 280ANV qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Bryant 280ANV - qui devraient nous aider dans les premières étapes lors de l'utilisation Bryant 280ANV
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Bryant 280ANV
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Bryant 280ANV dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Bryant 280ANV?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Bryant 280ANV, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Bryant 280ANV il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image