Manuel d’utilisation Cornelius TRIAD-150

17 pages 0.16 mb
Télécharger

Aller à la page of 17

Summary
  • Cornelius TRIAD-150 - page 1

    ICE/BEVERAGE DISPENSER MODEL: TRIAD–150 IMI CORNELIUS INC www .cornelius.com Operator ’ s Manual PRINTED IN U.S.A IMI CORNELIUS INC; 1998-2005 © Part No. 62091 1 101 May , 1998 Revised: December 19, 2005 Revision: C THIS DOCUMENT CONT AINS IMPORT ANT INFORMA TION This Manual must be read and understood before installing or operating this equip ...

  • Cornelius TRIAD-150 - page 2

    i 62091 1 101 Rev A May , 1998 T ABLE OF CONTENTS Page MAINTENANCE 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DAIL Y (OR AS REQUIRED) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WEEKL Y (OR AS REQUIRED) 1 . . . . . . . . . . ...

  • Cornelius TRIAD-150 - page 3

    1 62091 1 101 MAINTENANCE The following dispenser maintenance should be performed at the intervals indicated: DAIL Y (or as required) Remove foreign material from vending area drip tray to prevent drain blockage. WEEKL Y (or as required) Clean vending area. Check for proper water drainage from the vending area drip tray . MONTHL Y Clean and sanitiz ...

  • Cornelius TRIAD-150 - page 4

    2 62091 1 101 DISPENSER 1. CLEANING EXTERIOR SURF ACES Important: Perform the following daily . A. Remove the cup rest from drip tray . B. W ash the drip tray with soap solution. Rinse with clean water and allow solution to run down the drain. C. W ash cup rest with soap solution and rinse in clean water . Install the cup rest into the drip tray . ...

  • Cornelius TRIAD-150 - page 5

    3 62091 1 101 BEVERAGE SYSTEM (IF APPLICABLE) W ARNING: Disconnect Power Before Cleaning! Do not use metal scrapers, sharp objects or abrasives on the ice storage hopper , top cover and the agitator disk, as damage may result. Do not use solvents or other cleaning agents, as they may attack the plastic material. Soap solution - Use a mixture of mil ...

  • Cornelius TRIAD-150 - page 6

    4 62091 1 101 n. Discard the tank of sanitizing solution and reconnect the product (syrup or pre-mix) tanks. Oper- ate the valves until all sanitizer has been flushed from the system and only product (syrup or pre- mix) is flowing. B. Sanitize syrup lines, B-I-B Systems a. Remove all the quick disconnects from all the B-I-B containers. b. Fill a su ...

  • Cornelius TRIAD-150 - page 7

    5 62091 1 101 W ARNING: If repairs are to be made to a product system, remove quick disconnects from the applicable product tank, then relieve the system pressure before proceeding. If repairs are to be made to the CO 2 system, stop dispensing, shut off the CO 2 supply , then relieve the system pressure before proceeding. If repairs are to be made ...

  • Cornelius TRIAD-150 - page 8

    6 62091 1 101 T rouble Probable Cause BEVERAGES NOT SWEET ENOUGH. A. Empty syrup tank. B. Faucet brix requires adjusting. BEVERAGES NOT COLD (UNITS WITH BUIL T -IN COLD PLA TE). A. Unit standing with no ice in hopper – no ice in cold plate cabinet. Contact your local syrup or beverage equipment distributor for additional information and troublesh ...

  • Cornelius TRIAD-150 - page 9

    7 62091 1 101 P ARTS LIST / EXPLODED VIEW ...

  • Cornelius TRIAD-150 - page 10

    8 62091 1 101 BEV P ANEL PEPSI BEV P ANEL PEPSI 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 51 52 52 52 52 52 53 54 54 54 54 57 57 58 59 60 61 61 63 64 64 64 66 67 68 69 72 FIGURE 1. CABINST SECTION EXPLODED VIEW ...

  • Cornelius TRIAD-150 - page 11

    9 62091 1 101 CABINET SECTION P ARTS LIST Index No. Part N o. Name 1 21491 Gate Slide 2 22081 Gate Restrictor 3 29303R Pla te, Mo tor Mounting 4 15346 Agitator Assy 5 29483 Cover , Rear W rapper 6 Contact Sales Lower Panel Assy 7 620019001 Electrical Box 8 29313 W rapper 9 Contact Sales Panel C/P Faucet Assy 10 27107 Bracket, Depressor Mtg. 1 1 101 ...

  • Cornelius TRIAD-150 - page 12

    10 62091 1 101 CABINET SECTION P ARTS LIST (CONT’D) 51 70456 3/16 Pop Rivet 52 70171 # 8-32 x 3/8 Phil. T russ 53 70178 # 8-32 x 1/2 Phil. T russ 54 70204 # 8 x 1/2 A S.S. Phil. T russ 55 71089 Shoulder Screw 56 70250 1/4-20 T russ HD Phil Screw SS 57 15501 15500 Push Lever , Ice Dispense Lever Ass’y (Cup Activated) 58 70260 1/4-20 x 1 Phil RD ...

  • Cornelius TRIAD-150 - page 13

    11 62091 1 101 1 13 4 18 17 16 15 22 7 11 19 11 19 6 9 22 22 10 3 2 5 22 8 19 FIGURE 2. ELECTRICAL BOX ASSEMBL Y EXPLODED VIEW ELECTRICAL BOX ASSEMBL Y Item No. Part No. Name 1 620303301 620302001 620302301 620303302 E-Box Ass’y , 1 15V (Ice only) E-Box Ass’y , 1 15V (B and BC Models) E-Box Ass’y , 220V (B and BC Models) E-Box Ass’y , 220V ...

  • Cornelius TRIAD-150 - page 14

    12 62091 1 101 SOLENOID ASSEMBL Y 1 2 3 4 5 6 7 9 10 11 12 13 14 4 8 FIGURE 3. SOLENOID ASSEMBL Y Item No. Part No. Name 32954 Gate Solenoid Ass’y , 120 V olt 33397 Gate Solenoid Ass’y , 240 V olt 1 28172 Plate, Solenoid Mounting 2 28173 Arm, Gate Lift 3 32957 Solenoid 4 50752 Isolator 5 50754 B earing, Gate Arm 6 70162 Screw , No. 8-32 By 1/4- ...

  • Cornelius TRIAD-150 - page 15

    13 62091 1 101 DRAIN 1 1 1 1 2 3 3 4 5 FIGURE 4. DRAIN FOR Z STYLE UNITS Item No. Part No. Name 1 70750 Hose Clamp 2 53170 Drain T ube 3 51280 Elbow 4 53293 Coupler 5 Contact Factory Lower Front Panel ...

  • Cornelius TRIAD-150 - page 16

    14 62091 1 101 W ARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workman- ship under normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or W ilshire product, in your country , please write, fax or telephone the IMI Cornelius office nearest you. Please provid ...

  • Cornelius TRIAD-150 - page 17

    www .cornelius.com IMI CORNELIUS INC. ...

Fabricant Cornelius Catégorie Beverage Dispenser

Les documents que nous recevons du fabricant de l'appareilCornelius TRIAD-150 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Cornelius
- manuels d’utilisations TRIAD-150
- fiches produit Cornelius
- dépliants
- ou étiquettes-énergie Cornelius TRIAD-150
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Cornelius TRIAD-150.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Cornelius TRIAD-150, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Cornelius TRIAD-150. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Cornelius TRIAD-150.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Cornelius TRIAD-150, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Cornelius TRIAD-150 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Cornelius TRIAD-150.

Le manuel d’utilisation complet Cornelius, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Cornelius TRIAD-150 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Cornelius TRIAD-150, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCornelius TRIAD-150 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Cornelius TRIAD-150 - qui devraient nous aider dans les premières étapes lors de l'utilisation Cornelius TRIAD-150
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Cornelius TRIAD-150
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Cornelius TRIAD-150 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Cornelius TRIAD-150?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Cornelius TRIAD-150, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Cornelius TRIAD-150 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)