    AP13592 (06/04) FOR YOUR SAFETY! — Do not store or use gasoline or other flammable vapors or liquids or other combustible materials in the vicinity of this or any other appliance. T o do so may result in an explosion or fir e. — WHA T T O DO IF YOU SMELL GAS ● Do not try to light any appliance. ● Do not touch any electrical switch; do not u ...

  • Rheem AP13592 - page 2

    Safety Information Safety Precautions . . . . . . . 3–6 LP Gas Models . . . . . . . . . . . 5 Installation Instructions Location . . . . . . . . . . . . . . . . . 7 W ater Connections . . . . . . 9-10 Gas Supply . . . . . . . . . . . . . . 1 1 High Altitude . . . . . . . . . . . . 11 V enting . . . . . . . . . . . . . . . . . 12 Remote Control . ...

  • Rheem AP13592 - page 3

    Be sure to r ead and understand the entire Use and Car e Manual before attempting to install or operate this water heater . It may save you time and money . Pay particular attention to the Safety Instructions. Failure to follow these warnings could r esult in serious bodily injury or death. Should you have problems understanding the instructions in ...

  • Rheem AP13592 - page 4

    ...

  • Rheem AP13592 - page 5

    5 Both LP and natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or r ecognize this odorant. If you are unsur e or unfamiliar with the smell of LP or natural gas, ask the gas supplier . Other conditions, such as “odorant fade”, which causes the odorant to diminish in intensity , can ...

  • Rheem AP13592 - page 6

    6 Have the installer show you the location of the gas shut-off valve and how to shut it off if necessary . T urn off the manual shut-off valve if the water heater has been subjected to overheating, fire, flood, physical damage or if the gas supply fails to shut off. ● Read this manual entirely befor e installing or operating the water heater . ? ...

  • Rheem AP13592 - page 7

    Installing the water heater . This water heater must be installed in accordance with these instructions, local codes, utility company requir ements, and/or in the absence of local codes, use the latest edition of the American National S tandard/National Fuel Gas Code. A copy can be purchased fr om either the American Gas Association, 400 North Capi ...

  • Rheem AP13592 - page 8

    8 Installing the water heater . Proper operation of the water heater r equires air for combustion and ventilation. Pr ovisions for combustion and ventilation air must comply with r eferenced codes and standards. Combustion and V entilation Air This water heater is for OUTDOOR installation ONL Y . It must NOT be installed indoors or in a confined sp ...

  • Rheem AP13592 - page 9

    9 W ater Supply Connections IMPOR T ANT : Do not apply heat to the HOT or COLD water connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to the water connections on heater . Any heat applied to the water supply fittings will permanently damage the internal components of the water heater . Mounting the W ater H ...

  • Rheem AP13592 - page 10

    10 Installing the water heater . Relief V alve A new pressur e relief valve, complying with the S tandard for Relief V alves and Automatic Gas Shut-Off Devices for Hot W ater Supply Systems, ANSI Z21.22, must be installed at the hot water outlet connection of the water heater at the time of installation. Local codes shall govern the installation of ...

  • Rheem AP13592 - page 11

    11 W ARNING: Do not attempt to convert this water heater for use with a differ ent type of gas other than the type shown on the rating plate. Such conversion could result in hazardous operating conditions. Leak T esting The water heater and its gas connections must be leak tested at normal operating pressures before it is placed in operation. T urn ...

  • Rheem AP13592 - page 12

    12 Installing the water heater . Flue T erminal Location The location of the vent terminal depends on the following minimum clearances and considerations (see illustration): T welve (12) inches above grade level and above normal snow levels. Four (4) feet below , or four (4) feet horizontally from any door , window , soffit, under eave vent or grav ...

  • Rheem AP13592 - page 13

    13 Remote Contr ol Installation One (1) remote control is provided with the water heater . Additional remote controls may be purchased separately . Up to three (3) remote controls can be used with this water heater . The following are considerations for determining the location of the remote control(s): ● ● DO NOT install any remote control out ...

  • Rheem AP13592 - page 14

    14 Installing the water heater . W ARNING: Field wiring connections and electrical grounding must comply with local codes, or in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFP A 70, or in Canada, Canadian Electrical Code, CSA C22.1 Part 1. Remote Control Connection T erminals Gas V alve PCB 18 A WG Ext ...

  • Rheem AP13592 - page 15

    15 Electrical Connection HARDWIRING THE ELECTRICAL CONNECTIONS: ● W iring should be carried out by a qualified electrician in accordance with local codes. ● The water heater requires 120 V AC/60Hz and should be properly grounded. ● DO NOT connect grounding wire to water pipes, gas pipes, telephone cables, lightning conductor circuits and to g ...

  • Rheem AP13592 - page 16

    16 Installing the water heater . T ypical Installation T o Hot W ater Faucet(s) Air Relief ...

  • Rheem AP13592 - page 17

    17 For increased energy ef ficiency , use pipe insulation. Please install the insulation, according to the illustrations above, making sure to insulate all the way to the top. Do not cover any drain or pressure valve(s). Do’ s ❑ Do check inlet gas pressure to ensure that it is within the range specified on the rating plate. ❑ Do provide adequ ...

  • Rheem AP13592 - page 18

    Installing the water heater . 18 A W ater Heater Location ❑ Installed OUTDOORS. ❑ Close to area of mostly used outlet. ❑ Protected from freezing temperatures. ❑ Proper clearance from combustible surfaces observed. ❑ Sufficient fresh air supply for proper operation of water heater . ❑ Air supply free of corrosive elements and flammable v ...

  • Rheem AP13592 - page 19

    19 Lighting the water heater . Before operating this water heater , be sure to r ead and follow the instructions on the label pictured below and all other labels on the water heater , as well as the warnings printed in this manual. Failure to do so can result in unsafe operation of the water heater resulting in pr operty damage, personal injury , o ...

  • Rheem AP13592 - page 20

    20 T ime/T emperatur e Relationship in Scalds W ater T emperature T ime T o Produce a Serious Burn 120°F More than 5 minutes 125°F 1 1 / 2 to 2 minutes 130°F About 30 seconds 135°F About 10 seconds 140°F Less than 5 seconds 145°F Less than 3 seconds 150°F About 1 1 / 2 seconds 155°F About 1 second T able courtesy of Shriners Burn Institute ...

  • Rheem AP13592 - page 21

    21 W ater T emperature Setting… Maximum water temperature occurs while the burner is on. T o determine the water temperature, turn on a hot water faucet and place a thermometer in the water stream. W ater temperature at the faucet may vary depending on season and length of pipe from the water heater . This water heater contains an electronically ...

  • Rheem AP13592 - page 22

    22 Car e and cleaning of the water heater . Routine Pr eventative Maintenance Properly maintained, your water heater will provide years of dependable trouble- free service. It is recommended that a periodic inspection of the burner , relief valve, air intake, water filter and flue terminal should be made by service personnel qualified in gas applia ...

  • Rheem AP13592 - page 23

    23 Burner Inspection V isually inspect the main burners annually . Through the sight glass, inspect the burner flame with the main burner off and inspect the main burner while firing. If any unusual burner operation is noted, the water heater should be shut off until qualified service assistance can be obtained. CAUTION: For your safety , cleaning ...

  • Rheem AP13592 - page 24

    24 Draining the W ater Heater Fr eeze Protection Where the water heater may be exposed to freezing conditions, even for a short period of time, be sure to drain all water from the unit as instructed above. Exposure to freezing conditions can occur from down draft of venting system or from installation in areas exposed to cold air . The water heater ...

  • Rheem AP13592 - page 25

    25 Befor e Y ou Call For Service… Problem Possible Cause  Check shutoff valve and open fully . Hot water faucet is not fully opened.  W ater piping is frozen.  Allow piping to thaw No electricity or water supply is cut off.  Unit is not "ON".  The temperature may be set too low .  Increase the temperature setting. Mixi ...

  • Rheem AP13592 - page 26

    26 Err or Code Guide Error Code Possible Cause Open the Gas Shutoff Valve completely.    1L Water heater has a build u p of lime  Contact a dealer for service. 99 Decrease of blower motor ventilation amount. (Operation Stops) 12 15 16 What To Do 11 The operation automatically stops when used for an hour continuously. Close the hot water ...

  • Rheem AP13592 - page 27

    ...

  • Rheem AP13592 - page 28

    28 IF YOU NEED SER VICE 1. Should you have any questions about your new water heater , or if it requires adjustment, repair , or routine maintenance, it is suggested that you first contact your installer , plumbing contractor or previously agreed upon service agency . In the event the firm has moved, or is unavailable, refer to the telephone direct ...

Fabricant Rheem Catégorie Water Heater

Les documents que nous recevons du fabricant de l'appareilRheem AP13592 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Rheem
- manuels d’utilisations AP13592
- fiches produit Rheem
- dépliants
- ou étiquettes-énergie Rheem AP13592
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Rheem AP13592.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Rheem AP13592, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Rheem AP13592. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Rheem AP13592.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Rheem AP13592, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Rheem AP13592 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Rheem AP13592.

Le manuel d’utilisation complet Rheem, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Rheem AP13592 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Rheem AP13592, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lRheem AP13592 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Rheem AP13592 - qui devraient nous aider dans les premières étapes lors de l'utilisation Rheem AP13592
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Rheem AP13592
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Rheem AP13592 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Rheem AP13592?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Rheem AP13592, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Rheem AP13592 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)