Rheem AP13592の取扱説明書

28ページ 1.91 mb
ダウンロード

ページに移動 of 28

Summary
  • Rheem AP13592 - page 1

    AP13592 (06/04) FOR YOUR SAFETY! — Do not store or use gasoline or other flammable vapors or liquids or other combustible materials in the vicinity of this or any other appliance. T o do so may result in an explosion or fir e. — WHA T T O DO IF YOU SMELL GAS ● Do not try to light any appliance. ● Do not touch any electrical switch; do not u ...

  • Rheem AP13592 - page 2

    Safety Information Safety Precautions . . . . . . . 3–6 LP Gas Models . . . . . . . . . . . 5 Installation Instructions Location . . . . . . . . . . . . . . . . . 7 W ater Connections . . . . . . 9-10 Gas Supply . . . . . . . . . . . . . . 1 1 High Altitude . . . . . . . . . . . . 11 V enting . . . . . . . . . . . . . . . . . 12 Remote Control . ...

  • Rheem AP13592 - page 3

    Be sure to r ead and understand the entire Use and Car e Manual before attempting to install or operate this water heater . It may save you time and money . Pay particular attention to the Safety Instructions. Failure to follow these warnings could r esult in serious bodily injury or death. Should you have problems understanding the instructions in ...

  • Rheem AP13592 - page 4

    ...

  • Rheem AP13592 - page 5

    5 Both LP and natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or r ecognize this odorant. If you are unsur e or unfamiliar with the smell of LP or natural gas, ask the gas supplier . Other conditions, such as “odorant fade”, which causes the odorant to diminish in intensity , can ...

  • Rheem AP13592 - page 6

    6 Have the installer show you the location of the gas shut-off valve and how to shut it off if necessary . T urn off the manual shut-off valve if the water heater has been subjected to overheating, fire, flood, physical damage or if the gas supply fails to shut off. ● Read this manual entirely befor e installing or operating the water heater . ? ...

  • Rheem AP13592 - page 7

    Installing the water heater . This water heater must be installed in accordance with these instructions, local codes, utility company requir ements, and/or in the absence of local codes, use the latest edition of the American National S tandard/National Fuel Gas Code. A copy can be purchased fr om either the American Gas Association, 400 North Capi ...

  • Rheem AP13592 - page 8

    8 Installing the water heater . Proper operation of the water heater r equires air for combustion and ventilation. Pr ovisions for combustion and ventilation air must comply with r eferenced codes and standards. Combustion and V entilation Air This water heater is for OUTDOOR installation ONL Y . It must NOT be installed indoors or in a confined sp ...

  • Rheem AP13592 - page 9

    9 W ater Supply Connections IMPOR T ANT : Do not apply heat to the HOT or COLD water connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to the water connections on heater . Any heat applied to the water supply fittings will permanently damage the internal components of the water heater . Mounting the W ater H ...

  • Rheem AP13592 - page 10

    10 Installing the water heater . Relief V alve A new pressur e relief valve, complying with the S tandard for Relief V alves and Automatic Gas Shut-Off Devices for Hot W ater Supply Systems, ANSI Z21.22, must be installed at the hot water outlet connection of the water heater at the time of installation. Local codes shall govern the installation of ...

  • Rheem AP13592 - page 11

    11 W ARNING: Do not attempt to convert this water heater for use with a differ ent type of gas other than the type shown on the rating plate. Such conversion could result in hazardous operating conditions. Leak T esting The water heater and its gas connections must be leak tested at normal operating pressures before it is placed in operation. T urn ...

  • Rheem AP13592 - page 12

    12 Installing the water heater . Flue T erminal Location The location of the vent terminal depends on the following minimum clearances and considerations (see illustration): T welve (12) inches above grade level and above normal snow levels. Four (4) feet below , or four (4) feet horizontally from any door , window , soffit, under eave vent or grav ...

  • Rheem AP13592 - page 13

    13 Remote Contr ol Installation One (1) remote control is provided with the water heater . Additional remote controls may be purchased separately . Up to three (3) remote controls can be used with this water heater . The following are considerations for determining the location of the remote control(s): ● ● DO NOT install any remote control out ...

  • Rheem AP13592 - page 14

    14 Installing the water heater . W ARNING: Field wiring connections and electrical grounding must comply with local codes, or in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFP A 70, or in Canada, Canadian Electrical Code, CSA C22.1 Part 1. Remote Control Connection T erminals Gas V alve PCB 18 A WG Ext ...

  • Rheem AP13592 - page 15

    15 Electrical Connection HARDWIRING THE ELECTRICAL CONNECTIONS: ● W iring should be carried out by a qualified electrician in accordance with local codes. ● The water heater requires 120 V AC/60Hz and should be properly grounded. ● DO NOT connect grounding wire to water pipes, gas pipes, telephone cables, lightning conductor circuits and to g ...

  • Rheem AP13592 - page 16

    16 Installing the water heater . T ypical Installation T o Hot W ater Faucet(s) Air Relief ...

  • Rheem AP13592 - page 17

    17 For increased energy ef ficiency , use pipe insulation. Please install the insulation, according to the illustrations above, making sure to insulate all the way to the top. Do not cover any drain or pressure valve(s). Do’ s ❑ Do check inlet gas pressure to ensure that it is within the range specified on the rating plate. ❑ Do provide adequ ...

  • Rheem AP13592 - page 18

    Installing the water heater . 18 A W ater Heater Location ❑ Installed OUTDOORS. ❑ Close to area of mostly used outlet. ❑ Protected from freezing temperatures. ❑ Proper clearance from combustible surfaces observed. ❑ Sufficient fresh air supply for proper operation of water heater . ❑ Air supply free of corrosive elements and flammable v ...

  • Rheem AP13592 - page 19

    19 Lighting the water heater . Before operating this water heater , be sure to r ead and follow the instructions on the label pictured below and all other labels on the water heater , as well as the warnings printed in this manual. Failure to do so can result in unsafe operation of the water heater resulting in pr operty damage, personal injury , o ...

  • Rheem AP13592 - page 20

    20 T ime/T emperatur e Relationship in Scalds W ater T emperature T ime T o Produce a Serious Burn 120°F More than 5 minutes 125°F 1 1 / 2 to 2 minutes 130°F About 30 seconds 135°F About 10 seconds 140°F Less than 5 seconds 145°F Less than 3 seconds 150°F About 1 1 / 2 seconds 155°F About 1 second T able courtesy of Shriners Burn Institute ...

  • Rheem AP13592 - page 21

    21 W ater T emperature Setting… Maximum water temperature occurs while the burner is on. T o determine the water temperature, turn on a hot water faucet and place a thermometer in the water stream. W ater temperature at the faucet may vary depending on season and length of pipe from the water heater . This water heater contains an electronically ...

  • Rheem AP13592 - page 22

    22 Car e and cleaning of the water heater . Routine Pr eventative Maintenance Properly maintained, your water heater will provide years of dependable trouble- free service. It is recommended that a periodic inspection of the burner , relief valve, air intake, water filter and flue terminal should be made by service personnel qualified in gas applia ...

  • Rheem AP13592 - page 23

    23 Burner Inspection V isually inspect the main burners annually . Through the sight glass, inspect the burner flame with the main burner off and inspect the main burner while firing. If any unusual burner operation is noted, the water heater should be shut off until qualified service assistance can be obtained. CAUTION: For your safety , cleaning ...

  • Rheem AP13592 - page 24

    24 Draining the W ater Heater Fr eeze Protection Where the water heater may be exposed to freezing conditions, even for a short period of time, be sure to drain all water from the unit as instructed above. Exposure to freezing conditions can occur from down draft of venting system or from installation in areas exposed to cold air . The water heater ...

  • Rheem AP13592 - page 25

    25 Befor e Y ou Call For Service… Problem Possible Cause  Check shutoff valve and open fully . Hot water faucet is not fully opened.  W ater piping is frozen.  Allow piping to thaw No electricity or water supply is cut off.  Unit is not "ON".  The temperature may be set too low .  Increase the temperature setting. Mixi ...

  • Rheem AP13592 - page 26

    26 Err or Code Guide Error Code Possible Cause Open the Gas Shutoff Valve completely.    1L Water heater has a build u p of lime  Contact a dealer for service. 99 Decrease of blower motor ventilation amount. (Operation Stops) 12 15 16 What To Do 11 The operation automatically stops when used for an hour continuously. Close the hot water ...

  • Rheem AP13592 - page 27

    ...

  • Rheem AP13592 - page 28

    28 IF YOU NEED SER VICE 1. Should you have any questions about your new water heater , or if it requires adjustment, repair , or routine maintenance, it is suggested that you first contact your installer , plumbing contractor or previously agreed upon service agency . In the event the firm has moved, or is unavailable, refer to the telephone direct ...

メーカー Rheem カテゴリー Water Heater

Rheem AP13592のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AP13592の取扱説明書
- Rheemの製品カード
- パンフレット
- またはRheem AP13592の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Rheem AP13592の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Rheem AP13592の取り付け説明書、サービスマニュアル、簡易説明書、またはRheem AP13592のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Rheem AP13592の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Rheem AP13592デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRheem AP13592を使用するのを助ける技術的文書のことです。説明書は通常、全てのRheem AP13592ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Rheemの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Rheem AP13592の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRheem AP13592の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Rheem AP13592に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Rheem AP13592デバイスの基本機能を使うにあたってのヒント。 Rheem AP13592のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Rheem AP13592に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRheem AP13592のメーカー/サービスへの連絡先に関する情報。

Rheem AP13592についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRheem AP13592の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRheem AP13592で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)